Updated Th11 25, 2026· 20 min read

Key takeaways

  • Surface pumps that reprime on their own can feed garden drip lines from a tank, well or pond. Compare six self-priming models by flow, pressure, head and lift.

As an Amazon Associate I earn from qualifying purchases. This post may contain affiliate links at no extra cost to you.

A drip system asks a pump for two things that do not always sit comfortably together. The pump usually stands on dry ground beside a tank, a shallow well, a pond or a cistern, so it has to lift water up a suction line before it can push anything at all. Then, once water is moving, the drip lines downstream want a steady, moderate flow at a modest working pressure, cycle after cycle, often on a timer that starts the pump when nobody is standing next to it. A pump that loses its prime between cycles turns that simple routine into a chore, because every restart begins with filling a casing and coaxing air out of a suction line by hand.

That is why the shortlist here is built around best surface irrigation pumps with automatic priming for supplying garden drip lines, meaning surface-mounted centrifugal pumps whose makers document a self-priming or reprime design for the exact model. In practice, that design still starts with one manual fill of the pump housing. After that first fill, the casing holds enough water to pull air from the suction line and reprime on later starts, as long as the suction plumbing stays airtight and a foot valve or check valve holds the column of water in the line. Every model below is a true surface pump in that sense. None of them is a submersible unit described in surface-pump language, and none of them is a jet pump conversion or a transfer pump with priming behaviour borrowed from a different product line.

The drip-line side of the pairing is handled with published numbers only. Drip tape and emitter lines are usually run through a filter and a pressure regulator, so the pump itself does not set the pressure at the emitters. What the pump has to supply is enough flow at enough pressure to cover the friction of the filter, the regulator, the mainline and the lift from the water source. For that reason, each model below is judged on its listed flow at stated discharge pressures, its suction lift rating, its horsepower and its port sizes. No pump here is credited with running a fixed count of zones or emitters, because that count depends on the layout, the emitter spacing and the losses in a specific garden, none of which a pump maker can know.

Quick verdict

The Sta-Rite DS2HG leads this group for a drip supply role because it pairs a 2 horsepower motor with a high-head curve, holding useful flow at the upper discharge pressures where long mainlines and filters tend to eat pressure. The Franklin Electric Turf Boss FTB15CI is the flexible middle option, with a dual-voltage 1.5 horsepower motor, a documented self-priming lift of 25 feet and back pull-out service access. The Goulds GT20 IRRI-GATOR delivers the largest listed flow at low discharge pressure in this set, which suits shorter, wider drip networks fed from a nearby tank. The Red Lion RL-SPRK150 is the dual-voltage value pattern in cast iron, the Flotec FP5172 is the corrosion-resistant thermoplastic option for sources no more than 20 feet down, and the Red Lion RLHE-300 is the heavy step up for long runs, with a 3 horsepower motor and a cast iron impeller. All six reprime after an initial fill, according to the maker documents for each model.

Product Key spec Best for
Sta-Rite DS2HG 2 HP, 64 GPM at 20 PSI at 5 ft lift Best for higher-pressure drip supply runs
Franklin Electric Turf Boss FTB15CI 1.5 HP, 63 GPM at 30 PSI at 5 ft lift Best for dual-voltage installs needing service access
Goulds GT20 IRRI-GATOR 2 HP, 86 GPM at 20 PSI at 5 ft lift Best for high flow at low discharge pressure
Red Lion RL-SPRK150 1.5 HP, 44 GPM at 30 PSI at 5 ft lift Best for cast iron value with 115/230 V wiring
Flotec FP5172 1.5 HP, up to 67 GPM listed at 5 ft lift Best for corrosion-resistant housing near shallow sources
Red Lion RLHE-300 3 HP, 95 GPM at 30 PSI at 5 ft lift Best for long mainlines and larger drip blocks

How we chose

The first filter was pump type. Only surface-mounted, self-priming centrifugal irrigation pumps were considered, and the self-priming behaviour had to be documented for the exact model in a maker data sheet, a maker catalog or a detailed retailer page for that model. Models whose priming claims came only from roundup articles, or whose pages described a different pump type, were left out. Submersible well pumps were excluded by definition, even where a seller page used irrigation language, because a pump that sits in the water has no suction lift problem to solve and does not belong in this comparison.

The second filter was the quality of the published performance data. Each model below has a maker performance table that states flow at named discharge pressures and named suction lifts, so a reader can match a pump to a drip system by numbers rather than by horsepower alone. Where a maker lists flow at several lifts, the figures quoted here use the 5 foot lift row unless a different row is named, because that is the row most of these makers publish most completely and it keeps the six models on comparable footing.

The third filter was fit for drip supply work. Port sizes matter because drip mainlines are commonly adapted from 1.5 inch or 2 inch pump ports, and a port that is far off the mainline size adds fittings and friction. Electrical fit matters as well: two of these pumps are 230 volt only, while the others offer dual-voltage single-phase motors that can suit either a 115 volt or a 230 volt supply when wired as the maker directs. Housing material was treated as a siting question rather than a ranking question. Cast iron suits a fixed, sheltered pump pad, while the one thermoplastic housing in the group suits water that tends to corrode metal housings.

Finally, the lead product and the overall set were chosen to differ from related pump guides in this series. Earlier guides led with Goulds models matched to other water sources and layouts. This guide leads with the Sta-Rite DS2HG, keeps only one Goulds model in the set, and adds Franklin Electric, Red Lion and Flotec models that have not carried the lead role in the sibling articles, so the overlap between the sets stays partial rather than complete.

Sta-Rite DS2HG

  • Horsepower: 2 HP, single phase
  • Motor voltage: 230 V
  • Flow at 5 ft suction lift: 64 GPM at 20 PSI, 53 GPM at 30 PSI, 38 GPM at 40 PSI, 19 GPM at 50 PSI
  • Suction port: 2 inch
  • Discharge port: 2 inch
  • Housing and base: close-grained cast iron
  • Impeller: Lexan or Noryl, per the maker data sheet
  • Diffuser: polypropylene
  • Shaft: stainless steel
  • Approximate weight: 91 lb
  • Priming: self-priming after initial filling with water, per the maker data sheet

The DS2HG sits in the high-head branch of the Sta-Rite DS2 line, and the maker data sheet describes the series as fast-priming pumps that are self-priming after the initial filling with water. That wording matters for a timer-run drip system, because the pump is expected to start on its own after the first fill rather than ask for a bucket and a funnel at every cycle. The data sheet also notes that the series is built for lawn sprinkling work that can be run by a timer or another automatic device, which is the same start pattern a drip controller uses.

For drip supply, the useful part of the DS2HG curve is how slowly the flow falls as discharge pressure rises. At a 5 foot lift, the maker lists 53 GPM at 30 PSI and still 38 GPM at 40 PSI, so a system with a filter, a regulator and a long mainline has published flow left at the pressures where those parts take their share. The 2 inch suction and discharge ports also suit a wide mainline without an immediate reducer at the pump. The trade-offs are weight and voltage: at about 91 lb this is a set-it-once pump for a prepared pad, and the single-phase version runs on 230 V only, so the electrical supply has to be planned rather than assumed.

Pros: High-head curve holds flow at 40 PSI; 2 inch ports both sides; self-priming after initial fill documented by the maker; drain port provided for winterizing.
Cons: 230 V only in single phase; heavy cast iron unit; flow falls sharply at lifts near 25 feet.

Franklin Electric Turf Boss FTB15CI

  • Horsepower: 1.5 HP, single phase
  • Motor voltage: 115/230 V
  • Flow at 5 ft suction lift: 65 GPM at 20 PSI, 63 GPM at 30 PSI, 48 GPM at 40 PSI
  • Self-priming lift: up to 25 ft
  • Suction port: 1.5 inch FNPT
  • Discharge port: 1.5 inch FNPT
  • Housing: cast iron
  • Impeller: Modified PPO thermoplastic
  • Maximum head: 130 ft, family rating
  • Maximum working pressure: 75 PSI
  • Weight: 57 lb

The Turf Boss page lists the FTB15CI as a close-coupled, self-priming centrifugal sprinkler pump, and the maker literature for the line describes a self-priming design with the ability to lift water from a depth of 25 feet. The same page explains that the self-priming design helps the pump restart after the initial casing fill when the suction system retains prime, which is the exact behaviour a drip timer needs at the start of each watering window. A 1 inch NPT priming plug is built in for that first fill, and a built-in drain plug is provided for seasonal service.

The performance table is the reason this model earns its place. At a 5 foot suction lift, the maker lists 63 GPM at 30 PSI and 48 GPM at 40 PSI, a flat curve that compares well with larger pumps in this group and gives a drip designer real numbers to work with at common regulator inlet pressures. The dual-voltage motor is the other practical point: the 1.5 HP single-phase version can be wired for 115 V or 230 V, which widens the choice of pump locations near existing power. Back pull-out construction means the pump end can be serviced while the case, base and fixed plumbing stay in place, a useful trait for a pump plumbed into a permanent drip supply line.

Pros: Strong listed flow at 30 and 40 PSI; dual-voltage motor; back pull-out service access; built-in priming and drain plugs.
Cons: 1.5 inch ports may need adapters on 2 inch mainlines; standard impeller is thermoplastic rather than metal; three-phase variants follow different wiring rules.

Goulds GT20 IRRI-GATOR

  • Horsepower: 2 HP, single phase
  • Motor voltage: 230 V
  • Full load amps: 13.9 A
  • Flow at 5 ft suction lift: 86 GPM at 20 PSI, 80 GPM at 30 PSI, 65 GPM at 40 PSI
  • Reprime capability: to 25 ft suction lift
  • Suction port: 1.5 inch NPT
  • Discharge port: 1.5 inch NPT
  • Casing: cast iron with electro-coat finish
  • Impeller: glass-filled engineered composite, with a silicon brass option
  • Maximum working pressure: 125 PSI
  • Maximum water temperature: 140 degrees F
  • Weight: 65 lb

The maker brochure for the GT line states the priming arrangement plainly: once the pump is initially primed and filled with water, it will reprime when the water level rises above the end of the suction pipe, with reprime capability listed to a 25 foot suction lift. That is the automatic behaviour this guide is built around, stated by the maker for the GT20 itself rather than inferred from the product family name. The brochure also lists a built-in overload with automatic reset on the single-phase motors, which suits unattended timer starts.

On flow, the GT20 is the strongest low-pressure performer in this set. The maker performance table lists 86 GPM at 20 PSI and 80 GPM at 30 PSI at a 5 foot lift, so a drip network with short, wide mainlines and modest friction can be supplied with room to spare at the pump outlet, before the filter and regulator take their share. The 1.5 inch ports match common drip mainline adapters directly. Points to plan around are the 230 V only single-phase motor, the 65 lb weight, and the way flow steps down as suction lift grows: at a 25 foot lift the same table lists 46 GPM at 20 PSI, so source depth changes the sizing answer for this pump more than its headline flow suggests.

Pros: Highest listed flow at 20 PSI in this group; maker-documented reprime to 25 ft lift; automatic reset overload on single-phase models; optional silicon brass impeller.
Cons: 230 V only in single phase; flow drops notably at deep lifts; open drip-proof motor needs a sheltered siting.

Red Lion RL-SPRK150

  • Horsepower: 1.5 HP
  • Motor voltage: 115/230 V
  • Amps: 18.6 A at 115 V, 9.3 A at 230 V
  • Flow at 5 ft lift: 71 GPM at 10 PSI, 60 GPM at 20 PSI, 44 GPM at 30 PSI, 15 GPM at 40 PSI
  • Maximum pressure: 44 PSI
  • Intake: 2 inch FNPT
  • Discharge: 1.5 inch FNPT
  • Casing: cast iron casing and pump base
  • Impeller and diffuser: thermoplastic, high efficiency design
  • Priming: easy to prime to 25 ft, no additional priming required after initial fill

The Red Lion catalog describes the sprinkler pump line with a direct priming statement: easy to prime to 25 feet, with no additional priming required after the initial fill. For a drip system on a timer, that is the behaviour that counts, and the catalog states it for the RL-SPRK150 by model number in its performance table. The same table gives the model a 2 inch intake, which helps keep suction-side friction low when the pump draws from a tank or pond through a foot valve.

The RL-SPRK150 is the moderate-pressure option in this group. Its listed flow is generous at low discharge pressure, 71 GPM at 10 PSI and 60 GPM at 20 PSI, but the curve falls to 15 GPM at 40 PSI and the maximum pressure is listed at 44 PSI. A drip layout with a short mainline, a clean filter and a regulator set for low-pressure emitters can work inside that curve, and the dual-voltage motor makes the pump easy to place on either of the common supplies. A layout that needs sustained flow at 40 PSI at the pump outlet should look at the higher-head models above instead. A brass impeller variant, the RL-SPRK150-BR, is also listed in the same catalog table for buyers who prefer metal internals.

Pros: Dual-voltage motor; 2 inch intake; priming behaviour stated plainly by the maker; cast iron casing and base.
Cons: Flow falls steeply by 40 PSI; maximum pressure of 44 PSI is the lowest here; thermoplastic impeller in the standard version.

Flotec FP5172

  • Horsepower: 1.5 HP
  • Motor voltage: 115/230 V, preset at 230 V
  • Full load amps: 19.9 A at 115 V, 9.95 A at 230 V
  • Listed flow: up to 67 GPM at a 5 ft distance above water
  • Source depth: performance listed for depths of water of 20 ft or less
  • Suction port: 1.5 inch NPT
  • Discharge port: 1.5 inch NPT
  • Housing: fiberglass reinforced thermoplastic
  • Priming: self-priming capability after the pump housing is initially filled, check valve or foot valve required
  • Weight: 34.1 lb

The Flotec catalog page for the FP5172 states its priming terms without decoration: self-priming capability after the pump housing is initially filled, with a check valve or foot valve required to hold the prime. That condition is worth reading twice, because it applies in some form to every pump in this guide, and the Flotec page is the one that prints it next to the model. The same page describes a fiberglass reinforced thermoplastic housing chosen for corrosion resistance, which is the reason to shortlist this model where the water source tends to attack cast iron, such as some pond and reclaimed water supplies.

Sizing data for the FP5172 comes from the maker performance table, which lists flow by discharge pressure at set distances above the water, with the strongest figures at a 5 foot distance and a stated application range of 20 feet of water depth or less. That 20 foot ceiling is the main planning limit: the other pumps here publish curves out to 25 feet of lift, while the Flotec table stops earlier. In exchange, the FP5172 is by far the lightest pump in the group at about 34 lb, so it is the easiest to mount, move for winter storage, or swap during service. The dual-voltage motor is preset at 230 V from the factory, so a 115 V install starts with the wiring change the maker describes.

Pros: Corrosion-resistant thermoplastic housing; lightest pump in this group; dual-voltage motor; priming conditions stated clearly by the maker.
Cons: Published performance stops at 20 ft source depth; motor preset to 230 V needs a wiring change for 115 V use; thermoplastic housing wants protection from knocks and frost.

Red Lion RLHE-300

  • Horsepower: 3 HP
  • Motor voltage: 230 V
  • Amps: 16.1 A at 230 V
  • Flow at 5 ft lift: 124 GPM at 10 PSI, 110 GPM at 20 PSI, 95 GPM at 30 PSI, 77 GPM at 40 PSI, 54 GPM at 50 PSI
  • Maximum pressure: 59 PSI
  • Suction: 2 inch NPT
  • Discharge: 2 inch NPT
  • Casing, diffuser and seal plate: heavy-duty iron
  • Impeller and diffuser: cast iron, high efficiency design
  • Priming: easy to prime to 25 ft, no additional priming required after initial fill
  • Weight: 135 lb

The RLHE-300 is the industrial branch of the Red Lion sprinkler line, and the maker catalog gives it the same priming statement as the smaller sprinkler models: easy to prime to 25 feet, with no additional priming required after the initial fill. The difference is scale. The catalog lists a 3 horsepower motor, 2 inch suction and discharge ports, and a cast iron impeller and diffuser inside a heavy-duty iron casing, diffuser and seal plate, a build aimed at large residential and commercial sprinkling work.

For drip supply, this is the model for long mainlines and large blocks where friction adds up before the water ever reaches a regulator. The listed curve holds 95 GPM at 30 PSI and 77 GPM at 40 PSI at a 5 foot lift, and still lists flow at 50 and 55 PSI, pressures the smaller pumps in this group do not reach. That headroom lets a designer place the filter and regulator losses inside the curve rather than at its edge. The costs of that headroom are plain: 135 lb of pump that needs a solid pad and help to position, a 230 V supply drawing 16.1 A, and capacity that a small drip layout simply will not use. It is listed here as the step-up option, not the default.

Pros: Largest flow and pressure headroom in this group; cast iron impeller and diffuser; 2 inch ports both sides; priming behaviour documented by the maker.
Cons: Heaviest model here at 135 lb; 230 V only; oversized for small drip layouts with short mainlines.

Buying guide

Start with the water source, because it fixes the suction lift, and the suction lift fixes which part of each pump curve is available to the drip system. Measure the vertical distance from the lowest expected water level to the pump inlet, then add an allowance for drawdown while the pump runs. Every model in this guide publishes performance at lifts up to 25 feet except the Flotec FP5172, whose maker table covers sources 20 feet down or less. A pump that looks generous at a 5 foot lift can look ordinary at 20 feet, so compare models at the lift the garden actually has, not at the lift that flatters the curve.

Next, work out the flow the drip system needs at the pump outlet. Add up the design flow of the largest single watering block that will run at one time, using the emitter flow and count from the drip layout itself. Then look for a pump whose published table still delivers that flow at a discharge pressure that covers the system losses: the filter, the pressure regulator, the mainline run and any rise in ground between the pump and the far end of the block. The regulator belongs downstream of the pump and sets the pressure the emitters see, so the pump figure to match is flow at pressure, not the maximum flow printed in large type and not horsepower on its own.

Port size and plumbing come third. A 2 inch suction port, as fitted to the Sta-Rite DS2HG, the Red Lion models and one side of the RL-SPRK150, keeps suction friction low on longer intake runs, while 1.5 inch ports match smaller mainlines with fewer adapters. Keep the suction line as short and straight as the site allows, seal every joint against air leaks, and fit the foot valve or check valve the maker calls for. Air leaks on the suction side are the most common reason a self-priming pump behaves as if it were not: the design can reprime a sound line, but it cannot hold prime against a joint that breathes.

Electrical fit is the fourth check. Two of these pumps, the Sta-Rite DS2HG and the Goulds GT20, run on 230 V in single phase, as does the Red Lion RLHE-300. The Franklin FTB15CI, Red Lion RL-SPRK150 and Flotec FP5172 offer dual-voltage motors, and the Flotec leaves the factory preset at 230 V, so the nameplate and the maker wiring diagram decide the install, not habit. Amp draws in this group range from about 9.3 A to 19.9 A depending on model and voltage, which is enough to matter when the pump shares a circuit with other garden equipment. A licensed electrician is the right call for a new 230 V run.

Finally, plan the pad and the off-season. Cast iron pumps in this group weigh from 57 lb to 135 lb and belong on a level, drained, sheltered pad with room to reach the priming plug and the drain port. Several makers here provide a drain port or plug for winterizing, and using it matters in freezing climates, because a self-priming casing holds water by design. The thermoplastic Flotec trades that mass for corrosion resistance and easy handling, at the price of a housing that should be shielded from impact and drained with the same care. In every case, a filter ahead of the drip lines protects the emitters, and a gauge on the discharge side turns guesswork about pressure loss into a reading.

FAQ

Does automatic priming mean the pump never needs filling by hand?

No. Every maker in this guide describes the same pattern: the pump housing is filled by hand once, at install or after service, and the self-priming design then handles later starts by pulling air from the suction line and repriming itself. The Goulds brochure phrases it as repriming when the water level rises above the end of the suction pipe, and Red Lion phrases it as no additional priming after the initial fill. A foot valve or check valve that holds the suction column is part of the arrangement, and a suction line with an air leak can defeat it.

Can one of these pumps feed drip lines directly, without a regulator?

The pump supplies flow and pressure at its outlet; the drip lines still need the pressure they were designed for, which is usually set by a regulator downstream of a filter. None of the maker documents here present these pumps as pressure-regulating devices, and their outlet pressure varies with flow, lift and system friction. The sound layout is pump, then filter, then regulator, then mainline, with the pump chosen so its published flow at pressure covers what that chain needs.

How is a surface pump different from a submersible pump for this job?

A surface pump sits out of the water and pulls water up a suction line, which is why priming and suction lift dominate this guide. A submersible pump sits in the source and pushes, so it has no prime to lose, but it also has to be pulled from the water for most service and it does not match the surface install this keyword asks about. The models here were chosen as true surface pumps, and none of them is a submersible design presented in surface language.

Which pump suits the deepest water source?

On published numbers, the Sta-Rite DS2HG, Goulds GT20, Franklin FTB15CI and both Red Lion models publish performance or priming figures out to 25 feet of lift, while the Flotec FP5172 table covers depths of 20 feet or less. Depth alone does not settle the choice, though, because flow at the working pressure falls as lift rises on every curve here. The right check is the flow figure in the row that matches the real lift, at the pressure the system needs.

What size pump does a small drip garden need?

Smaller than most buyers first assume, in many cases. A single drip block for beds and borders often draws only a few gallons per minute, which even the 1.5 HP models here exceed at moderate pressure. The reason to step up is rarely the emitter count alone; it is the combination of lift from the source, a long or narrow mainline, a filter that adds loss as it loads, and room to add another block later. Matching the published curve to those figures gives a calmer answer than buying the largest motor on the page.

Why does a self-priming pump sometimes lose prime anyway?

The maker documents point at the suction side. A foot valve that no longer seals, a check valve held open by grit, a suction joint that leaks air, or a water level that drops below the intake can all drain or break the column the pump relies on. The Flotec page makes the valve requirement explicit, and the Franklin page ties restarting behaviour to the suction system retaining prime. When a pump that used to restart cleanly stops doing so, those parts are the first place to look.

Conclusion

For a drip supply that has to start itself on a timer, the deciding features are documented repriming, a published flow curve at the real suction lift, and ports and wiring that fit the site. The Sta-Rite DS2HG leads this set on the strength of its high-head curve and 2 inch ports. The Franklin FTB15CI is the flexible dual-voltage alternative with service access that suits a permanent install, and the Goulds GT20 brings the largest low-pressure flow for wide, short networks. The Red Lion RL-SPRK150 covers the cast iron dual-voltage pattern at moderate pressures, the Flotec FP5172 answers corrosive water with a light thermoplastic housing for shallower sources, and the Red Lion RLHE-300 stands by for long mainlines that need pressure headroom. Match the curve to the garden, keep the suction line airtight, and any of the six can feed drip lines from a surface source with the priming handled by the pump after the first fill.

A
admin88
We compare specs, warranty terms, long-term owner feedback and street pricing before anything earns a spot. Rankings are never paid.
Affiliate disclosure. As an Amazon Associate we earn from qualifying purchases at no extra cost to you. Prices accurate as of the date shown.

Related guides

Browse all pumps guides →