A storage tank solves the water problem and creates a pumping problem. The tank sits where the rain falls or the delivery truck can reach, which is rarely where the beds, rows, or sprinklers are, and gravity alone gives a trickle that no sprinkler will turn with. Gardeners searching for the best surface irrigation pumps for pumping from remote storage tanks need a pump that lives above ground beside the tank, primes itself after the first fill, lifts water out of the tank, and pushes it down a long line at useful pressure.
Every pump below is a surface pump in the strict sense: it sits dry beside or above the water, draws through a suction hose dropped into the tank, and is built for irrigation duty. The sprinkler pumps, led by the Red Lion RL-SPRK100, move the largest volumes at sprinkler pressure. The jet pumps trade some flow for higher pressure and finer control, which suits drip lines and long, rising runs.
Two numbers decide whether a pump and a tank work together: suction lift, the height the pump can pull water up from the tank surface to its inlet, and the flow it still delivers at the pressure your sprinklers or emitters need. Every product section below quotes both from the maker's or retailer's page, and the buying guide shows how to match them to a real tank on a real slope, because a pump chosen on headline flow alone is the commonest disappointment in tank irrigation.
Quick verdict
For most tank setups the Red Lion RL-SPRK100 is the anchor pick: 1 HP, up to 63 GPM, about 45 psi, and self-priming to 25 feet of lift, which covers a pump sitting well above a tank's low water line. The Everbilt EFLS15CI-HD moves even more water, up to 4,020 GPH through a cast iron housing, for bigger sprinkler zones. Where the line runs long or uphill and pressure matters more than volume, the Red Lion RJS-100-PREM jet pump's 71 psi ceiling earns its place, and the Goulds GT10 IRRI-Gator is the heavy-duty cast iron option built to reprime reliably season after season.
| Product | Key spec | Best for |
|---|---|---|
| Red Lion RL-SPRK100 Sprinkler Pump | 1 HP, 63 GPM max, 45 psi, self-priming to 25 ft | Most tank-to-sprinkler setups |
| Everbilt 1-1/2 HP Cast Iron Lawn Sprinkler Pump EFLS15CI-HD | 1.5 HP, up to 4,020 GPH, lift up to 20 ft | Large zones and long sprinkler runs |
| Pentair Flotec FP5182 Thermoplastic Sprinkler Pump | 2 HP, 69 GPM, 2 in ports, 115/230V | Highest flow for multi-head zones |
| Flotec FP5242 1.5 HP Cast Iron Sprinkler Pump | 1.5 HP, 55 GPM max, max lift 25 ft, drain port | Tanks in cold climates needing winter drain-down |
| Goulds GT10 IRRI-Gator Self-Priming Centrifugal Pump | 1 HP, 53 GPM, reprimes to 25 ft lift, cast iron | Hard-working permanent installations |
| Red Lion RJS-100-PREM 1 HP Jet Pump | 1 HP, max 71 psi, 16.4 GPM at 40 psi, pressure switch | Drip lines and long rising pipe runs |
| Pentair Flotec FP5172 Thermoplastic Sprinkler Pump | 1.5 HP, 67 GPM, 1.5 in ports, 115/230V | Mid-size zones wanting thermoplastic lightness |
How we chose
The first filter was position: only pumps designed to sit above the water and draw through a suction line were considered, which is the arrangement a storage tank demands. Submersible models were set aside, because a tank owner who can drop a pump inside the tank has a different and simpler problem. The second filter was priming behaviour. Every pump here is listed as self-priming, most with the honest qualifier that it self-primes after an initial fill, and each section states the lift figure the maker publishes.
The third filter was duty. Irrigation from a tank means long runs at steady pressure, so the list favours cast iron or reinforced thermoplastic sprinkler and jet pumps with published flow at pressure, dual voltage motors, and housings that drain for winter. Specs come from the maker and retailer pages in the sources file, quoted as listed; where a figure is a maximum at zero lift, the section says so, because tank owners live at the other end of the curve.
Red Lion RL-SPRK100 Sprinkler Pump
- Power: 1 HP, 115/230V dual voltage
- Flow: up to 63 GPM maximum
- Pressure: up to 44-45 psi
- Priming: self-priming to 25 ft lift
- Ports: 2 in intake, 1.5 in discharge
- Housing: cast iron
The RL-SPRK100 is the pump this guide is built around because its published figures line up with what a tank actually asks. Self-priming to 25 feet of lift means the pump can sit on a stand above the tank, or on the ground beside a tall tank, and still pull water up and over reliably after the first fill. Up to 63 GPM at a maximum near 45 psi is sprinkler territory: enough to run a pair of medium rotors or a healthy drip zone with a regulator, delivered through a 2 inch intake that does not starve the pump at full draw.
Cast iron construction suits a pump that lives outdoors beside a tank, and the dual voltage motor lets it run from a standard outlet now and a heavier circuit later if the setup grows. Red Lion lists this as a lawn irrigation sprinkler pump, which is precisely the duty cycle a storage tank imposes: long, steady runs rather than short bursts. Set it on a level pad, keep the suction hose short and fat, fit a foot valve in the tank, and it will start each session primed and ready.
Pros:
- Self-priming to 25 ft covers tall tank placements
- 63 GPM and 45 psi suit real sprinkler zones
- Cast iron housing for outdoor life
- Dual voltage motor gives wiring flexibility
Cons:
- Maximum flow is quoted at low lift, so expect less at height
- Cast iron weight makes it a fit-and-leave pump
- No built-in pressure tank or switch in the listing
Everbilt 1-1/2 HP Cast Iron Lawn Sprinkler Pump EFLS15CI-HD
- Power: 1.5 HP, 115/230V with change switch
- Flow: up to 4,020 GPH
- Lift: up to 20 ft
- Priming: self-primes after initial fill
- Housing: cast iron
- Warranty: 1 year listed
When the tank feeds a big sprinkler zone, flow is the currency, and the Everbilt EFLS15CI-HD brings the largest headline figure in this guide: up to 4,020 gallons per hour from a 1.5 HP motor in a cast iron housing. The retailer page lists lift up to 20 feet and self-priming after the initial fill, which together describe a pump happy to sit beside a ground-level tank and pull from near the bottom as the level drops through the season.
The cast iron body is the right material for a pump that will live outside under a lean-to beside the tank, shrugging off knocks and weather that crack lighter housings. The dual voltage change switch keeps installation simple on either a household circuit or a heavier line. Treat the flow figure as a maximum, as with every pump here: at the top of its lift range with sprinklers demanding pressure, delivered flow will be lower, but the margin this pump starts with is exactly what a large zone needs. The one year warranty listed is the shortest here, which is worth weighing against the output.
Pros:
- Highest flow figure in this guide at up to 4,020 GPH
- Cast iron housing suits permanent outdoor siting
- Self-primes after the initial fill
- Simple voltage change switch
Cons:
- One year warranty is the shortest listed here
- Lift ceiling of 20 ft is lower than the Red Lion
- Large motor wants a healthy circuit at start-up
Pentair Flotec FP5182 Thermoplastic Sprinkler Pump
- Power: 2 HP, 115/230V, preset to 230V
- Flow: up to 69 GPM
- Ports: 2 in suction and discharge
- Housing: fiberglass reinforced thermoplastic
- Priming: self-priming after initial fill
The FP5182 is the output leader among the thermoplastic pumps: 2 HP and up to 69 GPM through full 2 inch ports, in a fiberglass reinforced thermoplastic housing that will never rust beside a damp tank. That combination suits the biggest tank-fed zones in this guide, the kind running three or four sprinkler heads at once, where port size becomes the limit long before motor power does.
Thermoplastic earns its place at a tank for a second reason: tanks sweat, splash at filling, and sit in weather, and a housing that cannot corrode removes one whole category of ageing. The motor arrives preset to 230V per the listing, so plan the circuit accordingly or have the voltage changed at installation. As with its smaller siblings, it self-primes after the initial fill and wants a foot valve and a short, wide suction line to show its best behaviour. For a large, permanent tank system that must move serious water, this is the high-output option.
Pros:
- 69 GPM through 2 in ports for multi-head zones
- Thermoplastic housing cannot rust by the tank
- 2 HP motor holds pressure at high draw
- Self-priming after the initial fill
Cons:
- Preset to 230V, so wiring needs planning
- Output is wasted on small drip-only setups
- Thermoplastic wants shading from direct sun for longest life
Flotec FP5242 1.5 HP Cast Iron Sprinkler Pump
- Power: 1.5 HP, 115/230V
- Flow: 55 GPM maximum, 42 GPM at 10 ft lift and 30 psi
- Lift: maximum 25 ft
- Pressure: maximum 47 psi
- Housing: cast iron
- Feature: drain port for winterising listed
The FP5242 stands out for a detail that tank owners in cold climates will appreciate immediately: the retailer listing notes a drain port for winterising. A pump beside an outdoor tank faces the same freeze risk as the tank itself, and a housing that drains fully through a proper port survives winters that crack pumps emptied only by tipping and hoping. That single feature, on a 1.5 HP cast iron sprinkler pump, makes it the cold-climate pick in this guide.
Its performance figures are quoted with unusual honesty on the page: 55 GPM maximum, and 42 GPM at 10 feet of lift against 30 psi, which is exactly the kind of working-point figure a tank owner should shop by. Maximum pressure of 47 psi and lift to 25 feet cover most tank placements, from a ground tank on a pad to a raised tank on a low stand. Cast iron weight keeps it planted, and the dual voltage motor keeps the wiring options open.
Pros:
- Drain port listed for proper winterising
- Working-point flow quoted at real lift and pressure
- Cast iron housing, 25 ft maximum lift
- 47 psi ceiling suits sprinklers and drip with a regulator
Cons:
- Heavier than the thermoplastic Flotec models
- Maximum figures still fall as lift rises
- No pressure switch listed for automatic demand use
Goulds GT10 IRRI-Gator Self-Priming Centrifugal Pump
- Power: 1 HP, 115/230V
- Flow: up to 53 GPM
- Priming: self-priming centrifugal, reprimes to 25 ft lift
- Ports: 1.5 in NPT
- Weight: 52 lb
- Housing: cast iron
The GT10 IRRI-Gator is the professional's entry in this guide, a self-priming centrifugal pump from a maker whose name is on pump houses everywhere, and its key listed virtue is repriming: the retailer page states it reprimes to 25 feet of lift, which is the behaviour that matters when a tank system sits idle between waterings and the suction line inevitably loses a little of its charge. A pump that recovers its prime on its own saves the walk to the tank with a jug of water at the start of every session.
Output of 53 GPM from 1 HP through 1.5 inch ports suits a medium sprinkler zone or a long drip network, and the 52 pound cast iron build tells you this is a bolt-it-down installation rather than a portable tool. Goulds pumps are also supported by a wide parts network, which matters for a machine expected to work a decade beside a tank. It costs more than the big-box names here, and the guide makes no apology for including it: for a permanent tank installation, repriming reliability is worth paying for once.
Pros:
- Reprimes to 25 ft lift after idle periods
- Cast iron build and 52 lb planted feel
- Strong parts and service network
- 53 GPM suits medium zones well
Cons:
- Premium price against big-box rivals
- Weight rules out portable use
- 1.5 in ports cap the largest zones
Red Lion RJS-100-PREM 1 HP Jet Pump
- Power: 1 HP, 115/230V, 13/6.5 A
- Pressure: maximum 71 psi
- Flow: 16.4 GPM at 40 psi
- Priming: self-priming to 25 ft
- Ports: 1.25 in suction, 1 in discharge FNPT
- Housing: cast iron, with 30/50 psi pressure switch
Not every tank feeds sprinklers. Where the tank supplies drip lines, soaker runs, or a long pipe climbing to a high garden, pressure is worth more than raw flow, and the RJS-100-PREM is the pressure pick: a cast iron jet pump listing a 71 psi maximum and 16.4 GPM delivered at 40 psi, with a 30/50 psi pressure switch that starts and stops it on demand. That switch changes the whole feel of a tank system: open a valve at the far bed and the pump answers, close it and the pump rests.
Jet pumps earn their pressure by recirculating part of their flow through a jet assembly, which is why the volume figures look modest beside the sprinkler pumps. For drip irrigation that trade is ideal, since emitters sip rather than gulp, and the self-priming to 25 feet covers the same tank placements as the rest of the guide. Pair it with a small pressure tank if the listing's setup allows, keep the suction foot valve clean, and a remote tank starts behaving like a household tap at the end of the line.
Pros:
- 71 psi ceiling for long or rising lines
- Pressure switch gives on-demand operation
- 16.4 GPM at 40 psi is honest working-point data
- Self-priming to 25 ft like the sprinkler pumps
Cons:
- Flow too low for multi-head sprinkler zones
- Jet assembly adds parts that want clean water
- Smaller ports than the sprinkler pumps
Pentair Flotec FP5172 Thermoplastic Sprinkler Pump
- Power: 1.5 HP, 115/230V, preset to 230V
- Flow: up to 67 GPM
- Ports: 1.5 in
- Housing: fiberglass reinforced thermoplastic
- Priming: self-priming after initial fill, series rated for depths to water of 20 ft or less
The FP5172 is the middle path in the Flotec line: 1.5 HP, up to 67 GPM, and a fiberglass reinforced thermoplastic housing, sized for the tank owner whose zone is bigger than the Red Lion handles comfortably but who does not need the FP5182's 2 inch ports. The manual figures describe the series as performing at depths to water of 20 feet or less, which honestly frames its lift envelope for tank work: keep the pump within that vertical distance of the tank's low water line and it will deliver near its curve.
Like its siblings it self-primes after the initial fill and arrives preset to 230V, so the installation conversation starts with the circuit. The thermoplastic housing suits a damp tank-side slab and shrugs off the splashes of filling day. In a guide full of cast iron, this and the FP5182 make the case that the modern reinforced housing is a legitimate permanent choice, lighter to install and immune to the rust that slowly eats an outdoor iron pump from the outside in.
Pros:
- 67 GPM from a corrosion-proof housing
- Lighter to install than cast iron rivals
- Series performance honestly rated to 20 ft depth to water
- Self-priming after the initial fill
Cons:
- Preset to 230V from the factory
- Lift envelope smaller than the 25 ft pumps
- Thermoplastic prefers shade for longest service
Buying guide
Lift, head, and flow: reading a pump curve like a tank owner
Three figures decide everything, and headline flow is the least honest of them. Suction lift is the vertical distance from the tank's water surface, at its lowest working level, up to the pump inlet. Every pump here lists a lift figure between 20 and 25 feet, and flow falls as lift rises, so measure your worst case: tank nearly empty, pump on its stand. If that distance approaches the pump's ceiling, move the pump lower or choose the stronger lifter, because a pump at its limit primes slowly and delivers weakly.
On the discharge side, what matters is flow at pressure: the FP5242's listing, quoting 42 GPM at 10 feet of lift and 30 psi, is the model of how to read every pump here. Ask what the pump still delivers when your sprinklers are asking for their working pressure at the end of your longest line. A pump with a smaller headline number and a stronger mid-curve often waters better than a giant quoted only at zero lift.
The suction side decides whether the pump behaves
Most tank pump trouble is suction trouble. Keep the suction hose as short and as wide as the ports allow, drop it into the tank with a foot valve and strainer at its end, and seal every joint airtight, because a pinhole air leak on the suction side shows up as a pump that loses prime, surges, or rattles, and it is maddening to find. The foot valve holds the line's charge between sessions, which is what lets a self-priming pump start work quickly instead of grinding through a full reprime each time.
Set the strainer off the tank floor, where sediment collects, and check it whenever flow fades. Tank water carries algae, leaf fragments, and grit that well water never sees, and the strainer is the pump's only defence. A pump that has run dry because a strainer clogged can overheat quickly, so treat a fading sprinkler pattern at the far end as a message from the tank, not a fault in the pump.
Sprinkler zones or drip: match the pump family to the load
Sprinkler pumps and jet pumps solve different halves of the tank problem. Sprinkler pumps like the RL-SPRK100, the Everbilt, and the two Flotec models move large volumes at moderate pressure, which is what rotating heads consume. Jet pumps like the RJS-100-PREM move less water at higher pressure with a switch for on-demand use, which is what drip lines, long pipe runs, and rising ground consume.
Mixed systems are common: a sprinkler pump for the lawn zones and a valved branch with a pressure regulator for the drip beds is a sound pattern, while asking one jet pump to run four rotors is not. Count your heads, add their listed flows at working pressure, and choose the pump whose curve still covers that total at your lift. The arithmetic takes ten minutes and decides whether the system delights or disappoints for a decade.
Siting, shelter, and winter at the tank
A surface pump wants a level, drained pad, a short suction run, and a roof. A simple lean-to or pump cover keeps rain off the motor and sun off a thermoplastic housing, while leaving air room around the cooling fins. Keep the electrical run in proper outdoor conduit with a protected outlet, and put an isolation valve and a drain point at the pump so servicing does not mean emptying the line back into the tank.
Winter repeats the hose lesson at higher stakes: a pump housing holding water can crack in a freeze. Drain the pump through its plug or port, as the FP5242's listed drain port makes easy, drain the suction line, and leave drain plugs out with the ports screened against insects. Come spring, refit, refill the prime, and the system returns without the split housing that greets owners who skipped the ten minute drain-down.
FAQ
How far above the tank can a surface pump sit?
Within its listed lift, measured from the water surface at the tank's lowest working level to the pump inlet. The pumps here list 20 to 25 feet, but flow and priming ease fall as you approach the ceiling, so a placement within roughly two thirds of the listed figure is the comfortable working zone. If the tank is tall or the pump must sit high, lower the pump rather than hoping: a small excavated pad or a low stand beside the tank is cheaper than a bigger pump.
Why does my pump keep losing its prime between waterings?
Almost always the suction side. A foot valve that leaks back, a suction joint drawing air, or a strainer seal past its best will let the line drain toward the tank while the pump rests, and the next start begins with air instead of water. Work through the suction path joint by joint, renew the foot valve, and confirm the suction hose has no high loop where air can gather. Pumps listed as repriming, like the Goulds GT10, forgive small losses, but no pump should have to reprime from dry every session.
Can one of these pumps run drip irrigation from a tank?
Yes, with the right family and a regulator. Drip emitters want modest flow at low, steady pressure, which suits the jet pump here, the RJS-100-PREM, with its pressure switch and 71 psi ceiling feeding a regulator set to the emitters' rating. A sprinkler pump can also feed drip through a regulator and a valve, but its large flow at low demand can cycle and surge without a pressure tank in the line. Filter the tank water before the drip manifold either way, because tank sediment blocks emitters faster than almost anything else.
Do I need a foot valve and a strainer in the tank?
Yes to both. The foot valve holds the suction line's water between sessions so the pump starts primed, and the strainer keeps tank debris, algae, and sediment out of the pump's impeller and seals. Hang the strainer clear of the tank floor, where the worst sediment settles, and clean it whenever the far sprinklers fade. Skipping the foot valve turns every start into a full reprime; skipping the strainer trades a cheap screen for pump wear.
How do I winterise a pump that lives beside an outdoor tank?
Disconnect the power, open the pump's drain plug or port and the line drains, and let every part of the housing empty, tipping the pump if the maker allows to clear low pockets. Leave the drains open, screen the ports against insects, and store any removed plugs in a bag tied to the pump so spring reassembly is quick. The FP5242 in this guide lists a drain port for exactly this job. A housing drained in autumn is the difference between a spring start and a cracked casting.
Conclusion
A remote tank rewards the pump that respects its two hard facts: the water starts below the pump, and the garden is further away than it looks. The Red Lion RL-SPRK100 leads this guide because its 25 foot self-priming lift and 63 GPM at sprinkler pressure fit the widest range of real tank placements. The Everbilt and the Flotec FP5182 move more water for bigger zones, the FP5242 adds the winter drain port cold climates need, the Goulds GT10 reprimes like a professional tool, the RJS-100-PREM turns a tank into an on-demand pressure supply for drip and rising lines, and the FP5172 covers the middle ground in a housing that cannot rust. Measure your lift, count your heads, seal the suction side, and the tank stops being remote in every sense that matters.
Write Your Review