Updated Th11 25, 2026· 20 min read

Key takeaways

  • Compare centrifugal irrigation pumps for greenhouse bench watering, with listed flow at pressure, suction lift, horsepower and port sizes from each maker page.

As an Amazon Associate I earn from qualifying purchases. This post may contain affiliate links at no extra cost to you.

Greenhouse bench watering runs on a repeating pattern. A pump sits beside a tank or cistern, draws water through a short suction line, and pushes it into a manifold that feeds one bench zone at a time. A zone might carry drip lines laid along the bench, small spray stakes, or a short overhead line, and the pump starts and stops many times a day as the timer moves from zone to zone. That pattern calls for steady flow at moderate pressure, a suction side that holds water between cycles, and ports that match the pipe already running down the bench rows.

That is the job behind any shortlist of best centrifugal irrigation pumps for watering greenhouse benches. The six models below come from three long-running centrifugal lines: the Franklin Electric Turf Boss, the Sta-Rite Pro-Storm DS3, and the Goulds GT IRRI-Gator. Each one is a named, specific model, and each figure in this guide comes from a maker brochure, a maker specification sheet, or a retailer page that lists that model by number. The angle here is sizing by duty point rather than by headline flow: what matters at a bench is the flow a pump still delivers at the pressure a filter, a regulator, and a zone of emitters actually need, at the suction lift the tank layout imposes.

Bench systems also differ from open field sprinkling in one important way. A lawn zone draws a large, steady volume through a handful of heads, while a bench zone of drip lines draws a smaller volume for a longer time. A pump that looks oversized on a flow chart may still be the right pick if its curve stays strong at 30 or 40 PSI, because that is where a bench manifold with a filter and a pressure regulator tends to run. The sections below explain how the group was chosen, what each model lists, and how to match flow, lift, voltage, and port size to a bench layout before ordering.

Quick verdict

For most greenhouse bench setups, the Franklin Electric Turf Boss FTB15CI is the balanced starting point: the retailer page lists it as a 1.5 horsepower self-priming centrifugal pump with a cast iron casing, 1.5 inch suction and discharge, dual voltage operation, and a listed flow of 65 gallons per minute at 20 PSI with a 5 foot suction lift, still holding 48 gallons per minute at 40 PSI at the same lift. Growers with a smaller house or fewer zones can step down to the Goulds GT10, which lists 53 gallons per minute at 20 PSI and the same matched 1.5 inch ports in a 1 horsepower package.

At the higher flow end, the Sta-Rite DS3HG and the Goulds GT30 serve larger manifolds. The DS3HG lists 72 gallons per minute at 20 PSI with a 5 foot lift and uses a 2 inch suction and 2 inch discharge, while the GT30 lists 105 gallons per minute at 20 PSI with a 5 foot lift from a 3 horsepower motor. The Franklin FTB2CI and the Sta-Rite DS3HF fill the middle ground, and the main early filter across the whole group is voltage: most of these models switch between 115 and 230 volts, while the GT30 in single phase is 230 volt only, so the available circuit should be confirmed before any other detail is weighed.

Product Key spec Best for
Franklin Electric Turf Boss FTB15CI 65 GPM at 20 PSI, 5 foot lift, 1.5 HP Best for balanced bench zone watering
Goulds GT10 IRRI-Gator 53 GPM at 20 PSI, 5 foot lift, 1 HP Best for smaller houses and fewer zones
Sta-Rite DS3HF Pro-Storm 64 GPM at 20 PSI, 5 foot lift, 1.5 HP Best for 2 inch suction layouts
Franklin Electric Turf Boss FTB2CI 70 GPM at 20 PSI, 5 foot lift, 2 HP Best for longer bench runs at pressure
Sta-Rite DS3HG Pro-Storm 72 GPM at 20 PSI, 5 foot lift, 2 HP Best for 2 inch suction and discharge
Goulds GT30 IRRI-Gator 105 GPM at 20 PSI, 5 foot lift, 3 HP Best for large multi-zone greenhouses

How we chose

The first filter was pump type. Only centrifugal irrigation and sprinkler pumps were kept, and each kept model had to be documented as a centrifugal pump for that exact model on the page opened for it. The Franklin page describes the 1 to 2 horsepower Turf Boss as a close-coupled, self-priming centrifugal sprinkler pump. The Sta-Rite specification sheet heads the DS3 line as self-priming centrifugal. The Goulds brochure heads the GT IRRI-Gator line as self-priming centrifugal pumps. Jet pumps, diaphragm pumps, small transfer pumps, and submersible models were set aside, because bench watering needs the steady, higher volume flow this pump family is built to deliver.

The second filter was a specific model number with a full set of planning numbers on one opened page. Each kept model lists a flow figure tied to a stated pressure and suction lift, a horsepower, a voltage, suction and discharge sizes, and a housing material. Models with no flow figure, no port sizes, or no voltage on an opened page were left out. Where a line lists a maximum flow and a separate table of flow at pressure, the table figure is the one used for sizing here, because a bench system runs at a duty point, not at the open end of a curve.

The third filter was difference from the companion guide on the automatic priming version of this topic. That guide leads with a different pump and uses a different set, so this guide was built from three other model families and leads with the Franklin FTB15CI. Two models here come from the Turf Boss line, two from the Sta-Rite DS3 line, and two from the Goulds GT line, which gives a grower three separate answers to the same bench problem rather than six variations of one casing.

The fourth filter was fit for bench work rather than for lawn work alone. Every model here can feed a manifold, a filter, a pressure regulator, and a timer controlled set of zones, which is how bench systems are usually plumbed. Sprinkler head counts that some pages print were treated only as a rough flow reference, since a bench zone of drip lines draws water very differently from a lawn head. Finally, recalled models named in the program rules were excluded without exception, and no model was added on the strength of a review roundup alone; each one rests on a maker brochure, a maker specification sheet, or a retailer page opened for this guide.

Franklin Electric Turf Boss FTB15CI

  • Horsepower: 1.5 HP, single phase
  • Pump type: the retailer page lists a close-coupled, self-priming centrifugal sprinkler pump
  • Flow: 65 GPM at 20 PSI and 63 GPM at 30 PSI, at a 5 foot suction lift, as listed in the performance table
  • Flow at higher pressure: 48 GPM at 40 PSI at a 5 foot suction lift
  • Suction lift: up to 25 feet, as listed
  • Voltage: 115/230 volt, as listed in the ordering table
  • Ports: 1.5 inch FNPT suction and 1.5 inch FNPT discharge
  • Housing and impeller: cast iron casing, Modified PPO impeller, with a 304 stainless steel impeller version also listed
  • Maximum water temperature: 120 degrees Fahrenheit, as listed
  • Weight: 57 pounds, as listed in the ordering table

The FTB15CI leads this guide because its listed curve lines up with the middle of the greenhouse range. Bench zones rarely need the full open flow of a pump; they need flow that holds up after a filter and a regulator take their share of pressure. A listed 48 gallons per minute at 40 PSI, at a modest 5 foot lift, describes a pump that can push a bench zone through that hardware without running at the edge of its chart. The matched 1.5 inch ports suit the manifold pipe many bench systems already use, and the page notes back pull-out service access, which lets the pump end be serviced while the fixed plumbing stays in place. The dual voltage motor matters in real headhouses, where the circuit near the tank may be 115 volt even when the rest of the building runs heavier loads.

Pros: Strong listed flow at 40 PSI, matched 1.5 inch ports, dual voltage motor, and back pull-out service access.

Cons: Cast iron casing is heavy at 57 pounds, the suction line must stay airtight to hold prime, and flow falls as suction lift grows toward the listed limit.

Goulds GT10 IRRI-Gator

  • Horsepower: 1 HP, single phase
  • Pump type: the maker brochure lists the GT line as self-priming centrifugal pumps
  • Flow: 53 GPM at 20 PSI and 43 GPM at 30 PSI, at a 5 foot suction lift, as listed in the performance table
  • Flow at higher pressure: 29 GPM at 40 PSI at a 5 foot suction lift
  • Priming: the brochure lists a self-priming design that reprimes after the initial prime, with reprime capability to 25 feet of suction lift
  • Voltage: 115/230 volt for the 1 HP single phase model, as listed
  • Ports: 1.5 inch NPT suction and 1.5 inch NPT discharge
  • Housing and impeller: cast iron casing, glass-filled engineered composite impeller as standard
  • Seal: carbon and ceramic faces with Buna elastomers, as listed in the brochure
  • Maximum water temperature: 140 degrees Fahrenheit, as listed for the line
  • Weight: 52 pounds, as listed

The GT10 is the smaller house option in this group, and its appeal is proportion. A single greenhouse with a handful of bench zones does not need a 2 or 3 horsepower pump, and an oversized pump short-cycles against a regulator and wastes capacity the layout cannot use. The GT10 lists enough flow at 20 and 30 PSI for one bench zone at a time, in a 1 horsepower package with the same 1.5 inch ports as its larger siblings, so the plumbing plan stays simple. The brochure wording on priming is careful: once the pump is initially primed and filled with water, it will reprime when the water level rises above the end of the suction pipe. That suits a tank fed setup where the level moves through the day, provided the first prime is done by hand and the suction line is built airtight.

Pros: Right-sized 1 HP motor for smaller houses, matched 1.5 inch ports, dual voltage, and detailed reprime wording from the maker.

Cons: Flow at 40 PSI is the lowest in this group, the first prime must be done by hand, and larger manifolds will outgrow it.

Sta-Rite DS3HF Pro-Storm

  • Horsepower: 1.5 HP, single phase
  • Pump type: the maker specification sheet lists the DS3 line as self-priming centrifugal
  • Flow: 64 GPM at 20 PSI and 53 GPM at 30 PSI, at a 5 foot suction lift, as listed in the performance table
  • Priming: the sheet lists single-body-fill priming to 25 foot lifts
  • Voltage: 115/230 volt, with single phase motors shipped from the factory set at 230 volt, as noted on the sheet
  • Ports: 2 inch suction and 1.5 inch discharge
  • Housing and impeller: close-grained cast iron body and seal plate, Noryl impeller, reinforced polypropylene diffuser
  • Shaft: one-piece threaded 300 grade stainless steel, as listed
  • Extra: drain port provided for winterizing, as listed
  • Weight: 58 pounds, as listed

The DS3HF answers a different plumbing question from the two models above it. Its suction side is 2 inch while the discharge stays at 1.5 inch, a pairing that suits a longer suction run from a tank set a little farther from the pump pad, since a wider suction line loses less flow to friction on the way in. The listed flow nearly matches the FTB15CI at both 20 and 30 PSI, so the choice between them is mostly about suction layout, service habits, and which voltage setting the motor ships with. The sheet is plain that single phase motors leave the factory set at 230 volt, so a grower wiring to a 115 volt circuit should plan to change that setting before the first start. The drain port is a small detail with real value in an unheated house at the end of the season.

Pros: 2 inch suction suits longer suction runs, listed flow matches the group leaders, cast iron body, and a drain port for winterizing.

Cons: Motor ships set at 230 volt, the mixed port sizes may need an adapter on the suction side, and at 58 pounds it is a two person lift for most growers.

Franklin Electric Turf Boss FTB2CI

  • Horsepower: 2 HP, single phase
  • Pump type: the retailer page lists a close-coupled, self-priming centrifugal sprinkler pump
  • Flow: 70 GPM at 20 PSI and 69 GPM at 30 PSI, at a 5 foot suction lift, as listed in the performance table
  • Flow at higher pressure: 65 GPM at 40 PSI and 53 GPM at 45 PSI, at a 5 foot suction lift
  • Suction lift: up to 25 feet, as listed
  • Voltage: 230 volt, as listed in the ordering table
  • Ports: 1.5 inch FNPT suction and 1.5 inch FNPT discharge
  • Housing and impeller: cast iron casing, Modified PPO impeller, with a 304 stainless steel impeller version also listed
  • Line limits: maximum head of 130 feet and maximum working pressure of 75 PSI, as listed for the 1 to 2 HP line
  • Weight: 58 pounds, as listed in the ordering table

The FTB2CI is the pressure holder of the Franklin pair. Its listed curve barely moves between 20 and 40 PSI at a 5 foot lift, holding 65 gallons per minute at 40 PSI, which is the kind of flat performance that suits long bench runs, a filter that loads up slowly through the season, and zones at the far end of a house. That strength comes with a firmer electrical requirement: the ordering table lists the 2 horsepower single phase model at 230 volt, with no 115 volt option, so the circuit check comes first with this model. The casing, ports, and service layout match the FTB15CI, which makes the pair an easy step-up path: a grower who starts with the 1.5 horsepower model and later adds benches can move to this model without replumbing the pad.

Pros: Listed flow holds up well at 40 and 45 PSI, matched 1.5 inch ports, and the same pad layout as the smaller Franklin model.

Cons: 230 volt only in single phase, heavier power draw needs a circuit check, and the extra capacity is wasted on a small single-zone house.

Sta-Rite DS3HG Pro-Storm

  • Horsepower: 2 HP, single phase
  • Pump type: the maker specification sheet lists the DS3 line as self-priming centrifugal
  • Flow: 72 GPM at 20 PSI and 60 GPM at 30 PSI, at a 5 foot suction lift, as listed in the performance table
  • Flow at higher pressure: 45 GPM at 40 PSI at a 5 foot suction lift
  • Priming: the sheet lists single-body-fill priming to 25 foot lifts
  • Voltage: 115/230 volt, with single phase motors shipped from the factory set at 230 volt, as noted on the sheet
  • Ports: 2 inch suction and 2 inch discharge
  • Housing and impeller: close-grained cast iron body and seal plate, Noryl impeller, reinforced polypropylene diffuser
  • Line figures: high head models deliver up to 145 feet of head with capacities to 95 GPM, as listed for the line
  • Weight: 83 pounds, as listed

The DS3HG is the full 2 inch option in this guide, with both suction and discharge at 2 inch. That pairing suits a larger manifold that splits into several bench mains, where stepping a 2 inch discharge down through reducers at the pump would cost flow before the water reaches the first valve. Its listed flow at 20 PSI is the highest of the 2 horsepower models here, and it still lists 60 gallons per minute at 30 PSI at a 5 foot lift. The trade-offs are weight and wiring attention: at 83 pounds it is the heaviest model in this guide, and like its DS3HF sibling it ships set at 230 volt even though the motor can run at 115 volt. Plan the pad, the lift into place, and the voltage setting as part of the install, not as afterthoughts.

Pros: Full 2 inch ports suit larger manifolds, highest listed 20 PSI flow among the 2 HP models here, and dual voltage motor.

Cons: Heaviest model in this guide at 83 pounds, ships set at 230 volt, and 2 inch plumbing costs more to fit than 1.5 inch.

Goulds GT30 IRRI-Gator

  • Horsepower: 3 HP, single phase
  • Pump type: the maker brochure lists the GT line as self-priming centrifugal pumps
  • Flow: 105 GPM at 20 PSI and 92 GPM at 30 PSI, at a 5 foot suction lift, as listed in the performance table
  • Flow at higher pressure: 73 GPM at 40 PSI at a 5 foot suction lift
  • Priming: the brochure lists reprime capability to 25 feet of suction lift after the initial prime
  • Voltage: 230 volt only for the 3 HP single phase model, as listed
  • Ports: 1.5 inch NPT suction and 1.5 inch NPT discharge
  • Housing and impeller: cast iron casing, glass-filled engineered composite impeller as standard, with a silicon brass impeller option listed
  • Line limits: capacities to 110 GPM at a 5 foot suction lift and heads to 128 feet, as listed for the line
  • Weight: 76 pounds, as listed

The GT30 is the large house option, and it should be read as a capacity step rather than a default. Its listed flow at 20 PSI is about double the GT10 figure, and it still lists 73 gallons per minute at 40 PSI, which suits a greenhouse running several bench mains, longer houses where friction loss adds up, or a layout where two zones sometimes overlap. The surprise in its specification is the port size: suction and discharge stay at 1.5 inch, the same as the rest of the GT line, so a large manifold should be sized with that outlet in mind rather than assumed to be wider. The 3 horsepower single phase motor is 230 volt only, and a pump of this size belongs on a fixed pad with a planned circuit, a filter sized for its flow, and zones large enough to use what it delivers.

Pros: Highest listed flow in this group at every pressure shown, reprime capability to 25 feet, and the same service layout as the smaller GT models.

Cons: 230 volt only, 1.5 inch ports limit how the extra flow leaves the pump, and it is oversized for a single small house.

Buying guide

Start with the duty point, not the headline number. Add up what one bench zone draws at its planned pressure: the emitter or stake flow for the zone, at the pressure the regulator will hold. Then read each pump table at that pressure and at a suction lift close to the real one, which is the vertical distance from the water surface in the tank to the pump inlet, plus a margin for friction in the suction line. Every table in this guide shows flow falling as lift rises, so a pump chosen from its 5 foot lift figure will deliver less at a 15 or 20 foot lift. Choosing from the row that matches the actual lift avoids the most common sizing mistake.

Pressure deserves the same care. A bench system spends pressure in several places before water reaches a plant: the filter, the regulator, the main line, and the zone line all take a share. A pump that lists strong flow at 20 PSI but fades by 40 PSI may leave a far zone short once the filter loads up. The flatter curves in this group, such as the FTB2CI figure of 65 gallons per minute at 40 PSI, give more room for that slow change through a season. None of this calls for the largest pump by default; it calls for a pump whose listed flow at the working pressure clears the zone demand with modest room to spare.

Match the ports to the plumbing plan. Matched 1.5 inch ports, as on the Franklin models and the Goulds models, keep fittings simple and suit most bench manifolds. A 2 inch suction, as on both Sta-Rite models, helps when the suction run is longer or the lift is higher, because the wider line resists friction on the side of the system that can least afford it. A full 2 inch discharge, as on the DS3HG, suits a manifold that splits into several mains at once. Adapters can bridge a mismatch, but each reducer on the suction side is a place for an air leak, and air leaks are what break prime between cycles.

Check the electrical supply before falling for a flow figure. The 1 and 1.5 horsepower models here mostly offer 115 or 230 volt operation, while the GT30 and the FTB2CI in single phase are 230 volt only, and both Sta-Rite models ship set at 230 volt even when they can run at 115 volt. A pump wired for the wrong voltage, or a circuit sized for a smaller motor, turns a good pump into a nuisance. Read the voltage line on the page for the exact model, confirm the nameplate at install, and have a qualified electrician handle any circuit work.

Plan the suction side as carefully as the pump choice. Keep the suction line short, airtight, and sloping gently up toward the pump with no high loops that trap air. Fit the check valve or foot valve the maker calls for, keep the intake screened and clear of tank sediment, and set the pump on a solid, level pad where it can be drained at the end of the season. Models here list drain ports or casing drains for that job; use them, since water left in a cast iron casing through a hard freeze can crack the very housing that makes these pumps durable. A strainer or filter on the discharge side protects emitters, and it should be sized for the pump flow so the filter does not become the narrowest point in the system.

Finally, think about service over years, not weeks. Back pull-out designs, listed for the Franklin line and described in the Goulds brochure, let the pump end come apart for seal or impeller work without cutting the fixed plumbing. Mechanical seals are wear parts in every model here, and the makers list seal materials on the opened pages, which is a sign the parts path is documented. A grower who notes the exact model number, impeller material, and voltage setting at install will find any later parts order far simpler.

FAQ

How much flow does a greenhouse bench zone actually need?

It depends on the zone. Add the rated flow of every emitter, drip line section, or spray stake on the zone at its planned pressure, and that total is the zone demand. Then compare that total with the pump figure at the same pressure and at a realistic suction lift, not with the maximum flow printed for the line. The models here list between 53 and 105 gallons per minute at 20 PSI with a 5 foot lift, which covers most single-zone bench layouts with room to spare; a zone that draws more than the pump lists at its working pressure should be split into two zones.

Does self-priming mean the pump needs no setup on the suction side?

No. On the pages opened for this guide, the priming wording is conditional. Goulds lists a design that reprimes after the pump is initially primed and filled with water. Sta-Rite lists single-body-fill priming to 25 foot lifts. Franklin lists a self-priming design with lift from a depth of 25 feet. In each case the pump housing is filled at the first start, the suction line must stay airtight, and a check valve or foot valve holds water in the line between cycles. A suction side that leaks air will lose prime no matter which wording the page carries.

Which voltage should a greenhouse pump use?

Either can work, and the right answer is the circuit that already exists near the pump pad, matched to a model that lists that voltage. Dual voltage models in this guide include the FTB15CI, the GT10, and both Sta-Rite models, though the Sta-Rite motors ship set at 230 volt. The FTB2CI and the GT30 are 230 volt only in single phase. Larger motors generally suit 230 volt supply, and any new circuit or change should be handled by a qualified electrician who can size wire and protection for the motor draw.

Is a bigger pump safer for a growing greenhouse?

Not by itself. A pump far larger than the zone demand runs against a regulator, cycles more often, and can push a filter or a zone line harder than intended. The GT30 in this guide lists about double the GT10 flow at the same pressures, which suits a house that will genuinely add benches and mains. A grower planning one or two added zones is usually better served by the mid-size models, whose listed flow at 30 and 40 PSI already leaves headroom for a modest expansion.

How should these pumps be prepared for winter?

Drain the casing through the drain port or casing drain the maker provides, following the manual for the exact model. Both Sta-Rite models list a drain port for winterizing, and the Goulds brochure lists casing drain openings. Disconnect or drain exposed lines, keep the motor dry, and store any removed parts with a note of the model number and voltage setting so spring setup is straightforward. Water left in a cast iron casing through freezing weather can damage the housing.

Can one of these pumps draw from a rainwater tank?

The applications on the opened pages include water transfer and supply from tanks and cisterns, and the suction lift figures here, up to 25 feet as listed, describe how far below the pump the water surface can sit. A rainwater tank set beside the pump pad, with a short airtight suction line, a screened intake held off the tank floor, and a filter before the bench manifold, fits the way these pumps are meant to work. Water quality still matters: sediment and debris shorten seal and impeller life, so the intake screen and filter are part of the pump plan, not extras.

Conclusion

The right centrifugal pump for greenhouse benches is the one whose listed flow at the real working pressure and the real suction lift clears the largest zone demand with modest room to spare. The Franklin FTB15CI earns the lead here on the strength of its listed flow at 40 PSI, its matched 1.5 inch ports, and its dual voltage motor. The Goulds GT10 covers smaller houses in the same port size, the two Sta-Rite DS3 models answer layouts that need a 2 inch suction or a full 2 inch discharge, the FTB2CI holds flow at pressure for longer runs, and the GT30 stands ready for large multi-zone houses. Confirm the voltage, build the suction side airtight, size the filter for the flow, and any of these six can anchor a bench watering system for season after season of timer driven cycles.

A
admin88
We compare specs, warranty terms, long-term owner feedback and street pricing before anything earns a spot. Rankings are never paid.
Affiliate disclosure. As an Amazon Associate we earn from qualifying purchases at no extra cost to you. Prices accurate as of the date shown.