Key takeaways
- Compare centrifugal pumps for multi-zone lawn irrigation by flow at working pressure, head, suction lift and port size, across six verified models listed here.
What's inside
As an Amazon Associate I earn from qualifying purchases. This post may contain affiliate links at no extra cost to you.
A lawn split into several zones rarely fails because a pump is too weak on paper. It fails because the pump was chosen by a single headline number, usually horsepower or a maximum flow figure, while the zone that actually runs needs a specific flow at a specific pressure, after lift, pipe friction, and fittings have taken their share. When those losses are ignored, one zone runs well, the next zone runs thin, and heads at the far end of a line barely reach their intended radius. The fix starts before any model is chosen: add up the flow of the largest zone, note the pressure those heads need to operate as the maker intends, and then read pump tables at that pressure rather than at the most flattering point on the curve.
That is the approach used here for anyone comparing the best centrifugal irrigation pumps for multi zone lawn irrigation for a property where zones run one at a time from a well, lake, pond, or cistern. Every model below is a centrifugal irrigation pump from a line built for lawn sprinkling, and every figure comes from a page that lists flow at stated pressures and lifts. Maximum head figures are treated as ceilings, not as working points, because a pump delivers very little flow near its ceiling. A model that still delivers strong flow at 30 or 40 PSI, at a modest suction lift, is far more useful for zone work than a model with a taller ceiling and a thin flow figure where the sprinklers actually operate.
The six pumps in this guide span 1-1/2 to 2 horsepower in most cases, with one larger 2 horsepower Sta-Rite model included for higher pressure work, and they differ in port size, voltage, impeller material, and how their flow holds up as pressure rises. Those differences matter more than brand preference. A pump with a 2-inch suction can be easier to feed from a surface source, a pump that holds flow well at 40 PSI suits zones that need more pressure, and a dual-voltage motor can simplify wiring where a dedicated 230-volt circuit is not yet in place. Read the tables in that order, zone first and model second, and the shortlist usually narrows on its own.
Quick verdict
For most multi-zone lawns, the Goulds GT20 is the strongest starting point because the maker lists 86 GPM at 20 PSI and strong flow figures that stay high as pressure rises, with 1-1/2 inch connections on both sides. For a Franklin Electric option with a very flat flow curve across the working range, the Turf Boss FTB2CI lists 70 GPM at 20 PSI, 69 GPM at 30 PSI, and 65 GPM at 40 PSI at a 5-foot lift, which suits zones that need pressure as much as volume. Where a zone needs higher pressure from a cast iron Sta-Rite build, the DS2HG lists 64 GPM at 20 PSI and still lists flow at 50 PSI. The Red Lion RL-SPRK200 offers a 2-inch intake and a listed 65 GPM at 30 PSI for properties that prefer larger suction plumbing. The two 1-1/2 horsepower models, the Sta-Rite DS2HF and the Red Lion RL-SPRK150, suit smaller zone loads where their flow at 30 PSI matches the largest zone without paying for unused capacity.
None of these pumps should be sized by maximum flow alone. The Goulds and Franklin tables and the Sta-Rite and Red Lion tables all show the same pattern: flow falls as discharge pressure rises, and it falls further as suction lift grows. Match the largest zone first, confirm the electrical supply second, and check port sizes against the plumbing already planned.
| Product | Key spec | Best for |
|---|---|---|
| Goulds GT20 IRRI-Gator | 86 GPM at 20 PSI at 5 ft lift, heads to 128 ft as a ceiling | Best for larger zones needing high flow |
| Franklin Turf Boss FTB2CI | 65 GPM at 40 PSI at 5 ft lift, 1-1/2 x 1-1/2 in ports | Best for zones needing pressure and flow |
| Sta-Rite DS2HG | 53 GPM at 30 PSI at 5 ft lift, 2 x 2 in ports | Best for higher pressure zone work |
| Red Lion RL-SPRK200 | 65 GPM at 30 PSI at 5 ft lift, 2 in intake | Best for larger suction plumbing runs |
| Sta-Rite DS2HF | 45 GPM at 30 PSI at 5 ft lift, 2 in suction | Best for mid-size zones on 115/230 V |
| Red Lion RL-SPRK150 | 44 GPM at 30 PSI at 5 ft lift, max pressure 44 PSI | Best for smaller zones on dual voltage |
How we chose
The first filter was pump type. Only centrifugal pumps built and listed for lawn sprinkling or irrigation were considered, which in practice meant the Goulds GT IRRI-Gator line, the Franklin Electric Turf Boss line, the Sta-Rite DS line, and the Red Lion RL-SPRK line. Jet pumps, transfer pumps, and general utility pumps were left out, even when their headline flow looked attractive, because their tables are written for different duties and their pressure behaviour at sprinkler loads is different.
The second filter was evidence. Each model had to have a page that lists model-specific flow at stated discharge pressures, along with horsepower, voltage, and port sizes. A family headline such as a maximum flow for a whole range was not enough on its own. Where a maker lists a full grid by suction lift, that grid was preferred, because multi-zone systems are often fed from a source below the pump and lift changes the result. Where a page lists flow at 5 feet of lift, the figures in this article are quoted at that lift so models can be compared on a like basis.
The third filter was the multi-zone angle, handled only through listed flow at pressure. A zone is a set of heads that run together, so the pump has to deliver the combined flow of that set at the pressure those heads need. This article does not assign a number of zones to any pump, and it does not assign a head count where the maker does not list one, because zone size depends on nozzle choice, pipe length, and layout. Instead, each product section states the flow the maker lists at 20, 30, and where available 40 PSI, so a reader can compare those figures directly with the flow of their own largest zone.
The fourth filter was limits stated plainly. Maximum head is reported as a ceiling. Maximum pressure is reported as a limit, not as a working pressure. Suction lift limits are reported as listed, and flow figures are always tied to the lift and pressure in the source table. Electrical details were also part of the choice, since a 230-volt-only model and a dual-voltage model lead to different installation plans even when their flow figures look close.
Goulds GT20 IRRI-Gator
- Horsepower: 2 HP, single phase
- Voltage: 230 V
- Flow listed: up to 86 GPM at 20 PSI at a 5 ft suction lift
- Family limits: capacities to 110 GPM at a 5 ft lift, heads to 128 ft as a ceiling, maximum working pressure 125 PSI
- Connections: 1-1/2 in NPT suction and 1-1/2 in NPT discharge
- Construction: cast iron casing with electro-coat finish, glass-filled Noryl impeller
- Motor: NEMA standard open drip-proof, 3500 RPM, approximate weight 65 lb
The GT20 sits at the top of this list because its listed flow at low pressure is the highest among the 2 horsepower models with 1-1/2 inch ports, and the Goulds family table places it well above the 1 and 1-1/2 horsepower versions from the same line. For a multi-zone lawn, that matters when the largest zone is a wide open area with many heads running together and the pressure demand is moderate. The back pull-out design the maker lists also matters for ownership, since service can be carried out without disturbing the suction or discharge piping, which is a practical point on a permanent installation that runs on a timer all season. Buyers should confirm the 230-volt supply before choosing this model, because unlike the smaller GT15, the single-phase GT20 is listed at 230 volts only, and that requirement should be settled before plumbing is planned around it.
Pros: Highest listed flow at 20 PSI in this group, cast iron casing, service design that leaves piping in place
Cons: 230-volt only in single phase, 1-1/2 inch ports may need adapters on larger suction runs
Franklin Turf Boss FTB2CI
- Horsepower: 2 HP
- Flow listed at 5 ft lift: 70 GPM at 20 PSI, 69 GPM at 30 PSI, 68 GPM at 35 PSI, 65 GPM at 40 PSI, 53 GPM at 45 PSI, 35 GPM at 50 PSI
- Connections: 1-1/2 x 1-1/2 in FNPT
- Maximum suction lift: 25 ft as listed for the Turf Boss line
- Maximum water temperature: 120 degrees F
- Construction: cast iron case, modified PPO hydraulics with an optional 304 stainless steel impeller build
- Service: back pull-out design, speed 3600 RPM
The FTB2CI stands out for how flat its flow curve stays across the pressures that matter for sprinkler zones. Many pumps lose a large share of their flow between 20 and 40 PSI, while the product page lists this model moving from 70 GPM at 20 PSI to 65 GPM at 40 PSI at the same 5-foot lift. For a property where zones differ, some close to the pump and some at the end of longer runs with more friction, that steadiness makes planning easier, because the pump does not fall away as soon as a zone needs real pressure. The full grid on the product page also shows how lift changes the picture, with flow at 40 PSI listed at 58 GPM at a 10-foot lift and 48 GPM at a 15-foot lift, which is exactly the kind of detail a buyer with a source well below the pump needs before committing.
Pros: Flow holds up very well from 20 to 40 PSI, full lift grid published, back pull-out service access
Cons: Heavier class of pump to handle during installation, output drops notably at higher lifts
Sta-Rite DS2HG
- Horsepower: 2 HP, single phase
- Voltage: 230 V
- Flow listed at 5 ft lift: 64 GPM at 20 PSI, 53 GPM at 30 PSI, 38 GPM at 40 PSI, 19 GPM at 50 PSI
- Connections: 2 in suction and 2 in discharge
- Family limits: high head models deliver up to 145 ft of head as a ceiling, with capacities to 95 GPM
- Construction: close-grained cast iron body and base, Lexan or Noryl impeller, polypropylene diffuser, stainless steel shaft
- Motor: heavy-duty motor listed for continuous operation, 3450 RPM, approximate weight 91 lb
The DS2HG is the higher pressure option among the Sta-Rite models here. The maker lists flow at 50 PSI, a point several other models in this guide do not reach in their published tables, which makes this model worth a close look for zones on ground that rises away from the pump or for heads that need more pressure to reach their stated radius. Its 2-inch discharge is also larger than the 1-1/2 inch discharge found on several rivals, which can suit a main line sized for lower friction loss. The trade-off is weight and power supply: at 91 lb it is a two-person lift for most installers, and the single-phase version is listed at 230 volts. As with the other high head figures in this article, the 145-foot figure for the family is a ceiling, and the working choice should be made from the flow table at the pressure the zone needs.
Pros: Listed flow at 50 PSI, 2-inch suction and discharge, cast iron construction with stainless shaft
Cons: Heavy at 91 lb, flow at 40 PSI is lower than the Franklin 2 HP model
Red Lion RL-SPRK200
- Horsepower: 2 HP
- Voltage: 230 V, 10.9 A at 230 V
- Flow listed at 5 ft lift: 76 GPM at 10 PSI, 75 GPM at 20 PSI, 65 GPM at 30 PSI, 47 GPM at 40 PSI
- Maximum pressure: 49 PSI, maximum flow 76 GPM
- Connections: 2 in FNPT intake and 1-1/2 in FNPT discharge
- Construction: rugged cast iron casing and pump base, high efficiency thermoplastic impeller and diffuser
- Priming: the maker lists easy priming to 25 ft, with no additional priming required after the initial fill
The RL-SPRK200 gives buyers a different plumbing starting point, with a 2-inch intake paired to a 1-1/2 inch discharge. A larger suction side can help where the run from a lake, pond, or shallow well is long, since suction-side friction is harder for a pump to overcome than discharge-side friction. Its listed flow at 30 PSI, 65 GPM, matches the Franklin 2 horsepower model at 40 PSI, which puts it in the same working class for a large zone at moderate pressure. The ceiling to keep in mind is pressure rather than flow: the maker lists a maximum pressure of 49 PSI, so a zone design that needs sustained pressure close to that figure leaves little margin. For zones designed in the 20 to 35 PSI range, the listed figures are strong and the model is a straightforward fit.
Pros: 2-inch intake for suction runs, 65 GPM listed at 30 PSI, cast iron casing
Cons: Maximum pressure of 49 PSI limits high pressure zones, 230-volt only
Sta-Rite DS2HF
- Horsepower: 1-1/2 HP, single phase
- Voltage: 115/230 V
- Flow listed at 5 ft lift: 55 GPM at 20 PSI, 45 GPM at 30 PSI, 31 GPM at 40 PSI
- Connections: 2 in suction and 1-1/2 in discharge
- Family limits: high head models deliver up to 145 ft of head as a ceiling, with capacities to 95 GPM
- Construction: close-grained cast iron body and base, Lexan or Noryl impeller, polypropylene diffuser, stainless steel shaft
- Motor: heavy-duty motor listed for continuous operation, 3450 RPM, approximate weight 79 lb
The DS2HF is the mid-size Sta-Rite option, and its appeal is the combination of a 2-inch suction, dual voltage, and enough listed flow for a mid-size zone without stepping up to a 2 horsepower motor. At 30 PSI and a 5-foot lift the maker lists 45 GPM, which covers many residential zones built around moderate nozzle sizes, provided the pipe run is not unusually long. The lift grid is also useful reading: at a 15-foot lift the listed flow at 30 PSI falls to 39 GPM, and at a 25-foot lift it falls to 32 GPM, so a deeper source should be sized with those lower figures rather than the 5-foot row. A drain port is listed for winterizing, a small detail that matters in cold climates where a pump house is not heated.
Pros: Dual voltage motor, 2-inch suction, published lift grid for planning deeper sources
Cons: Flow at 40 PSI drops to 31 GPM, heavy for a 1-1/2 HP model at 79 lb
Red Lion RL-SPRK150
- Horsepower: 1-1/2 HP
- Voltage: 115/230 V, 18.6 A at 115 V and 9.3 A at 230 V
- Flow listed at 5 ft lift: 71 GPM at 10 PSI, 60 GPM at 20 PSI, 44 GPM at 30 PSI, 15 GPM at 40 PSI
- Maximum pressure: 44 PSI, maximum flow 71 GPM
- Connections: 2 in FNPT intake and 1-1/2 in FNPT discharge
- Construction: rugged cast iron casing and pump base, high efficiency thermoplastic impeller and diffuser
- Priming: the maker lists easy priming to 25 ft, with no additional priming required after the initial fill
The RL-SPRK150 is best understood as a moderate pressure pump. Its listed flow at 10 and 20 PSI is generous for a 1-1/2 horsepower model, and at 30 PSI it still lists 44 GPM, close to the Sta-Rite DS2HF at the same pressure. The sharp drop to 15 GPM at 40 PSI is the key limit, and it should rule this model out for zones that genuinely need 40 PSI at the heads after losses. For flatter properties with shorter runs, where the working pressure at the pump can stay near 30 PSI, that limit may never be reached in normal zone operation. Dual voltage is a practical plus here, since the motor can be wired for either supply, which helps when a pump is replaced and the existing circuit is already in place.
Pros: Dual voltage, strong listed flow at 10 to 30 PSI, 2-inch intake
Cons: Flow falls sharply at 40 PSI, maximum pressure of 44 PSI is the lowest in this group
Buying guide
Start with the largest zone, not with the pump. Walk the zone that has the most heads or the largest nozzles and add up the flow those heads use at their intended operating pressure. That total, in gallons per minute, is the minimum flow the pump must deliver, and it must deliver it at pressure, not at an open discharge. Then add the pressure the heads need, the pressure lost to friction in the main line and laterals, the lift from the water surface to the pump, and any rise from the pump to the highest head in the zone. Only after that total is clear does a pump table become useful, because the table lets a buyer find the row that matches the real lift and read across to the real pressure.
Read maximum figures with care. A maximum flow figure is measured at very low pressure and says little about sprinkler work. A maximum head figure is a ceiling reached as flow approaches zero, so it should never be treated as a working point. The figures that decide a purchase are the middle rows: flow at 30 PSI and flow at 40 PSI at the lift closest to the actual installation. In this guide, the Franklin FTB2CI holds its flow unusually well across that range, the Goulds GT20 leads at 20 PSI, the Sta-Rite DS2HG still lists flow at 50 PSI, and the Red Lion RL-SPRK150 drops sharply at 40 PSI. Those shapes are more informative than any single headline number.
Consider suction conditions early. A pump fed from a tank at the same level has an easier job than a pump lifting water from a lake surface or a shallow well below it. Every table in this guide shows flow falling as lift rises, sometimes by a large margin between a 5-foot row and a 25-foot row. Keep the suction run as short and as large in diameter as the port allows, limit fittings on the suction side, and use the lift row that matches the installation rather than the most favourable row. Where the source is a surface supply, a strainer and a foot valve or check arrangement should be planned as part of the system, following the pump maker instructions for that model.
Match ports to the plumbing plan. Models here use 1-1/2 inch, 2 inch, or mixed port sizes. A larger suction port does not by itself create more flow, but it can reduce suction friction on a longer run, and a larger discharge can suit a main line sized to keep friction down across a big property. Adapters are available for most combinations, yet each extra fitting adds loss, so a pump whose ports match the planned pipe sizes is usually the cleaner installation. Note the discharge size as well as the suction size, since several models pair a 2-inch intake with a 1-1/2 inch discharge.
Settle the electrical supply before ordering. Two models here are 230-volt only in the versions listed, while others offer 115/230-volt dual voltage motors. Amperage differs by voltage, and a dual-voltage motor still needs to be wired and configured for the supply actually used. A dedicated circuit, correct breaker sizing, and grounding should be handled to local code, and three-phase versions, where a line offers them, suit properties that already have three-phase service rather than homes that would need it added. Motor protection features listed by a maker, such as built-in overload protection on some lines, are worth noting but do not replace correct circuit protection.
Think about service and seasonal care. Back pull-out designs, listed for the Goulds and Franklin models here, allow service without cutting into the piping, which matters after several seasons when a seal or impeller needs attention. A drain port, listed for the Sta-Rite DS models, simplifies winterizing where freezing temperatures reach the pump. In any climate, a pump should be mounted level, protected from flooding, and given ventilation around the motor. Keep the area around the pump clear so fittings can be reached, and keep a record of the model, voltage setting, and the zone flow figures used for sizing, since that record makes later troubleshooting far simpler.
Finally, plan the controller and zone valves alongside the pump. A multi-zone system normally runs one zone at a time, so the pump is sized for the largest single zone rather than for all zones at once. If two zones could ever be opened together by a controller setting or a manual valve, the combined flow becomes the sizing figure and the pump choice changes. Pressure regulation at the zone level, where heads require it, should be handled in the zone design rather than by forcing the pump to run against a partly closed valve for long periods, which wastes energy and adds heat. A pressure gauge on the discharge, installed where it can be read during a zone run, gives the owner a simple way to confirm that the installed system behaves as the tables predicted.
FAQ
How do I size a centrifugal pump for several lawn zones?
Size for the largest single zone. Add up the flow of every head that runs together in that zone at its intended pressure, then find a pump whose published table delivers at least that flow at that pressure and at a suction lift close to the installation. Zones that run one at a time do not need their flows added together.
Why does flow fall so much between 20 PSI and 40 PSI on some models?
Flow and pressure trade against each other on every centrifugal pump curve. As discharge pressure rises, the pump moves less water. The tables here show the size of that trade clearly: the Red Lion RL-SPRK150 lists 60 GPM at 20 PSI and 15 GPM at 40 PSI, while the Franklin FTB2CI lists 70 GPM at 20 PSI and 65 GPM at 40 PSI at the same lift. That difference in curve shape is a central reason to compare models at working pressure.
Is a higher maximum head figure always better for a multi-zone system?
No. Maximum head is a ceiling reached near zero flow, so it describes a limit rather than a working condition. A pump with a lower ceiling but stronger listed flow at 30 or 40 PSI will usually run a sprinkler zone better than a pump with a taller ceiling and weaker flow at those pressures. Use the ceiling only to confirm that the system total head stays within the pump range.
Does suction lift really change which pump I should buy?
Yes. Published grids show flow falling as lift increases, and the drop can be large. The Sta-Rite DS2HF lists 45 GPM at 30 PSI at a 5-foot lift and 32 GPM at the same pressure at a 25-foot lift. A buyer with a deep source should size from the row that matches that depth, or choose a larger model so the required flow is still available at the real lift.
Should I choose 115/230-volt dual voltage or a 230-volt model?
Choose the model that matches the supply that can be provided at the pump location. Dual voltage models in this guide include the Sta-Rite DS2HF and the Red Lion RL-SPRK150, which can be wired for either supply. The Goulds GT20, Sta-Rite DS2HG, and Red Lion RL-SPRK200 are listed at 230 volts in the versions covered here, so they need that supply to be planned from the start.
Can one pump run two zones at the same time?
Only if the pump table shows enough flow for the combined demand of both zones at the required pressure, with lift and friction included. In most residential multi-zone layouts, zones are sequenced by the controller and run one at a time, which keeps the required flow to the size of the largest zone. Opening two zones together without sizing for it usually drops pressure and shortens head throw across both zones.
Conclusion
A multi-zone lawn rewards the buyer who sizes from the zone outward. The Goulds GT20 leads this group on listed flow at 20 PSI for large, moderate pressure zones. The Franklin Turf Boss FTB2CI offers the steadiest listed flow through 40 PSI, which suits mixed zones and longer runs. The Sta-Rite DS2HG reaches into higher pressure work with flow still listed at 50 PSI, while the DS2HF gives a dual-voltage, mid-size alternative with a published lift grid. The Red Lion RL-SPRK200 pairs a 2-inch intake with strong flow at 30 PSI, and the RL-SPRK150 suits smaller zones where working pressure stays near 30 PSI. Whichever model is chosen, the deciding evidence is the same: flow at the pressure and lift of the actual installation, read from the maker table, with maximum head treated only as a ceiling.