Key takeaways
- Compare submersible well pumps for multi-zone lawn irrigation by flow at pressure, head, horsepower and discharge size, from Grundfos, Goulds and Franklin.
What's inside
As an Amazon Associate I earn from qualifying purchases. This post may contain affiliate links at no extra cost to you.
Running several lawn zones from a private well is a flow-at-pressure problem before it is a horsepower problem. A zone is a group of sprinkler heads that run together, and each head needs a set flow at a set pressure at the head itself. Add up the heads in the largest zone, add the lift from the pumping water level in the well, add the pressure the heads need converted into feet of head, and add friction in the drop pipe and the main line. The pump that fits is the one whose published curve still delivers that flow at that total head. A pump with a large maximum flow figure can still fall short on a deep well, and a pump with a very high maximum head can still deliver too little water once pressure is included. That is why the best submersible well pumps for multi zone lawn irrigation are chosen from curves and output tables, not from a single headline number.
One reading rule applies to every model below. A maximum head figure is the shut-off point, the head at which flow reaches zero. No water reaches a sprinkler at shut-off, so that number is a ceiling for comparison, not a working point. The useful figures are the flow the maker lists at a stated head, or the gallons per minute the maker lists at a stated depth and pressure switch setting. Zone counts follow from those figures. If a pump delivers 20 gallons per minute at the pressure a zone needs, and each zone draws 10 gallons per minute, the arithmetic points to two zones of that size running one at a time in sequence, not to a fixed number of zones stamped on the pump. Change the head size, the pressure, the depth to water, or the pipe run, and the workable zone layout changes with it.
The six pumps below cover a useful spread for zoned lawn watering. Flows range from a 22 gallon per minute class up to a maker-listed maximum of 35 gallons per minute, horsepower runs from 1 to 2, and discharge sizes are 1-1/4 inch or 1-1/2 inch. Two models are 3 inch pumps for narrow casings, and the rest are 4 inch pumps. Wiring differs too, from a 2-wire pump with electronics built into the motor to 3-wire pumps that need a separate control box. Read the largest zone in your own layout against each curve, and let that comparison, rather than the order on this page, decide the short list.
Quick verdict
For many zoned lawns, the Grundfos 22 SQ15-220 is the strongest starting point because the maker lists 22 gallons per minute at 240 feet of head and a published output of 24.7 gallons per minute at 100 feet of depth on a 50 PSI switch setting, in a 3 inch, 2-wire package that needs no control box. The Goulds 25GS15 suits owners who want a 25 gallon per minute class pump end with a floating impeller stack and a field serviceable build. The Red Lion RL22G10-3W2V is the simpler 1 HP option in the 22 gallon per minute class, with a control box included as the maker lists. The Hallmark Industries MA0419X-12A carries the largest flow figure here, 35 gallons per minute as the product page lists, for shallow to mid-depth wells with big zones. The VEVOR 2 HP deep well pump pairs a 31.7 gallon per minute maximum with a 450 foot maximum head. The Franklin Electric Series V in its 25 gallon per minute, 1-1/2 HP build suits deeper settings where flow at pressure still matters, with published output at both 30 and 50 PSI.
| Product | Key spec | Best for |
|---|---|---|
| Grundfos 22 SQ15-220 | 22 GPM at 240 ft of head, 1-1/2 HP, 3 inch | Narrow wells with several mid-size zones |
| Goulds 25GS15 | 25 GPM class, 1-1/2 HP, 9 stages, 4 inch | Larger zones on a serviceable pump end |
| Red Lion RL22G10-3W2V | 22 GPM max flow, 1 HP, shut-off 260 ft | Straightforward 22 GPM class installs |
| Hallmark Industries MA0419X-12A | 35 GPM, 2 HP, 400 ft head as listed | Big zones needing high maximum flow |
| VEVOR 2 HP Deep Well Submersible Pump | 31.7 GPM max, 2 HP, 450 ft max head | High-flow deep well irrigation supply |
| Franklin Electric Series V 25 GPM 1-1/2 HP | Shut-off 289 ft, 195 ft of head at 26 GPM | Deeper wells feeding zoned systems |
How we chose
The first filter was type. Every model here is a submersible well pump, a sealed pump and motor unit that sits below the water in the casing and pushes water up the drop pipe. Surface pumps, jet pumps, and booster pumps were left out, because the keyword asks for submersible well pumps and because the sizing maths for a pump that pushes from depth differs from a pump that pulls or boosts at the surface. Models also had to be specific, named products with published figures, sold for well service, and the figures used here come only from pages opened for this article: maker material, a technical brochure, an owner manual, and retailer product pages.
The second filter was irrigation relevance. A zoned lawn system usually needs more flow than a single household tap group, so the set leans toward the 22 to 35 gallon per minute classes rather than the small 5 and 7 gallon per minute classes that serve cottages and single homes. Each model had to publish enough curve or output information to judge it at pressure, not only a maximum flow at no head. Where a maker publishes output at a 30/50 PSI pressure switch by depth to water, that table was given weight, because it maps closely onto how a zoned system with a pressure tank and a controller actually runs.
The third filter was spread. The set mixes 3 inch and 4 inch pumps, 2-wire and 3-wire motors, thermoplastic and stainless discharge heads, and horsepower from 1 to 2, so that a reader with a narrow casing, an existing control box, or a deep static level can each find a starting point. No model on the recall list for this programme appears here, and no model was kept if its published figures could not be read clearly enough to state without guessing. Where sources disagreed on a figure, the more conservative retailer or brochure figure was used and the conflict kept out of the article rather than averaged.
A final note on method. Depths in the output tables are depths to the pumping water level, not the total well depth and not the pump setting depth, and the makers state that pipe friction is not included in those tables. A real layout adds friction for the drop pipe, the main line, elbows, valves, and the lateral lines, plus any rise from the wellhead to the highest head. The comparisons below therefore rank pumps against each other on published figures; the final size for a given yard still needs the zone maths in the buying guide.
Grundfos 22 SQ15-220
- Rated flow: 22 GPM nominal, working range 7 to 33 GPM, as the product page lists
- Head at rated flow: 240 ft at 22 GPM
- Maximum head: 348 ft at zero flow, the shut-off point where flow reaches zero
- Output at 50 PSI: 24.7 GPM at 100 ft depth to water, 20.4 GPM at 140 ft, 15.1 GPM at 180 ft, as the product page lists
- Motor: 1-1/2 HP MS 3 permanent-magnet motor, 200-240 V, 60 Hz, 2-wire plus ground
- Discharge: 1-1/2 inch NPT
- Well size: 3 inch minimum casing
- Construction: stainless steel sleeve, floating impellers on tungsten carbide and ceramic bearings, built-in check valve
- Protection: dry-run, overvoltage and undervoltage, overload, and over-temperature protection built into the motor, as the product page lists
The 22 SQ15-220 leads this set because its published numbers stay strong where zoned systems actually work. At a 50 PSI switch setting, the product page lists 27.7 gallons per minute at 60 feet to water and 24.7 at 100 feet, which covers the draw of two mid-size rotor zones or one large zone with room to spare, run in sequence by the controller. The 1-1/2 inch discharge suits the larger main lines that those flows call for, and the soft start, with a run-up of about three seconds as the maker lists, is gentle on pressure tanks and switches that cycle many times a day across zones. Because the motor electronics are built in, there is no control box to mount or match, and the pump runs from the breaker through a pressure switch. The trade-offs are the 3 inch format itself, which caps flow compared with the largest 4 inch pumps, and the clean water limits the maker lists, pH 5 to 9 and up to 86 degrees, which a sandy or warm well should be checked against before ordering.
Pros: Strong flow at pressure on published tables, no control box needed, fits 3 inch casings, built-in motor protection as listed.
Cons: Clean water limits apply, 3 inch format caps maximum flow, drop cable and pressure tank are separate purchases.
Goulds 25GS15
- Series flow: 25 GPM at best efficiency, flow range 8 to 33 GPM, as the technical brochure lists
- Motor required: 1-1/2 HP
- Stages: 9 stages
- Discharge: 1-1/4 inch NPT
- Well size: 4 inch minimum
- Water end: 15.3 inches long, 9 pounds for the water end, as the brochure lists
- Construction: cast 303 stainless steel discharge head with built-in check valve, stainless casing, floating impeller stack, as the brochure lists
- Rotation: counterclockwise viewed from the discharge end, 3450 RPM class curves at 60 Hz
The 25GS15 is the traditional serviceable option in this set. The brochure describes a floating impeller stack, a design the maker presents as its sand handling approach, with impellers and diffusers in glass filled engineered composites and a hex shaft for positive drive. For a zoned system, the useful reading is the 25 gallon per minute best efficiency point inside an 8 to 33 gallon per minute range: a controller running zones near that point keeps the pump near the part of its curve the maker designed it around, rather than at the thin ends of the range. Nine stages on a 1-1/2 HP motor give the lift for mid-depth wells, and the water end is field serviceable with left hand threads as the brochure lists, which matters on farms and large lots where a local pump shop handles repairs. Buyers should note that the brochure figures describe the water end and its required motor, so the complete pump price and wiring depend on the CentriPro motor and, for 3-wire single phase units, the control box the brochure says is required with those units.
Pros: 25 GPM best efficiency point suits large zones, floating impeller stack as listed, field serviceable water end, stainless discharge head and casing.
Cons: Motor and control box selection add steps, 4 inch casing minimum, curve reading needed for exact flow at a given head.
Red Lion RL22G10-3W2V
- Maximum flow: 22 GPM, as the owner manual lists
- Maximum head: 260 ft shut-off, the point where flow reaches zero
- Motor: 1 HP, 3-wire, 230 V, 10.4 amps, as the manual lists
- Discharge: 1-1/4 inch FNPT, thermoplastic discharge head on the RL series
- Well size: 4 inch diameter and greater wells, to depths of 250 ft as the manual describes the range
- Control box: included with this 3-wire model, as the manual marks with its includes-control-box note
- Series: RL series, offered in 12 and 22 GPM models as the manual lists
The RL22G10-3W2V is the plain, mid-power entry in the 22 gallon per minute class. Its 1 HP motor draws 10.4 amps on 230 volts as the manual lists, a step down in electrical demand from the 1-1/2 and 2 HP models here, while the 260 foot shut-off ceiling still covers many mid-depth wells once pressure and friction are added, provided the flow at the working head meets the largest zone. That last clause is the honest limit of the published table: the manual gives maximum flow and shut-off for this model rather than a full set of flow-at-depth figures in the section read, so a buyer with a deep pumping level should ask the dealer for the full curve before committing. The included control box removes one matching task, and the manual sets out clear setting rules that suit irrigation wells, including keeping the pump at least 5 feet from the bottom of the well and above the screen or perforations unless cooling flow past the motor is assured. For shallow to mid-depth wells with moderate zones, that simplicity is the appeal.
Pros: 1 HP electrical demand, control box included as listed, clear setting guidance in the manual, 22 GPM class flow.
Cons: Thermoplastic discharge head rather than stainless, published table lacks flow-at-depth rows for this model, 3-wire install needs the box mounted in a protected spot.
Hallmark Industries MA0419X-12A
- Maximum flow: 35 GPM, as the product page lists
- Head: 400 ft, as the product page lists, read as the maximum head at the shut-off end of the curve
- Motor: 2 HP, 230 V, 60 Hz
- Construction: stainless steel housing, as the product page lists
- Well size: 4 inch, as the product page lists in its title specification
- Type: deep well submersible pump
The MA0419X-12A carries the largest maximum flow figure in this set, and that shapes its role. A 35 gallon per minute maximum does not mean 35 gallons per minute at working pressure on a deep well, because flow falls as head rises toward the 400 foot maximum, but on shallow to mid-depth wells it gives headroom for the biggest residential zones, such as a long rotor zone or a group of large nozzles that would starve a 12 or 15 gallon per minute pump. The 2 HP motor on 230 volts is the electrical price of that headroom, and the circuit, wire size over a long run, and pressure switch rating all need to suit a 2 HP load. Stainless construction is listed by the retailer, and the 4 inch format matches the most common drilled well casing size. Buyers should confirm the full performance curve and the discharge size with the seller before ordering, because the retailer page read for this article states the headline figures without a curve table, and zone sizing deserves the curve, not the headline.
Pros: Largest maximum flow in this set, 2 HP lift, stainless housing as listed, standard 4 inch format.
Cons: Headline figures without a published curve on the page read, 2 HP electrical demand, working flow at pressure must be confirmed from the curve.
VEVOR 2 HP Deep Well Submersible Pump
- Maximum flow: 31.7 GPM, as the maker lists
- Maximum head: 450 ft, the shut-off point where flow reaches zero
- Motor: 2 HP, stainless steel motor housing as the maker lists
- Protection rating: IP68, as the maker lists
- Cord: 9.84 ft cord, for standard 115 V outlets as the product page lists
- Use as listed: deep well pumping and large-scale irrigation among the uses the maker names
The VEVOR entry is the high-head, high-flow value format in this group. The maker lists a maximum head of 450 feet alongside the 31.7 gallon per minute maximum, and as with every model here those two maxima do not occur together: the working point sits on the curve between them, and the deeper the pumping level and the higher the pressure, the lower the delivered flow. For zoned lawn use, that still leaves a useful envelope for mid-depth wells running one zone at a time, and the maker names irrigation directly among its uses. The stainless motor housing and IP68 rating are the construction points the page lists. Two practical checks matter before ordering. First, the page describes a corded pump for standard 115 volt outlets, which is unusual at 2 HP, so the exact model variant, voltage, and amp draw should be confirmed on the listing variant being bought. Second, the page read gives maxima rather than a flow-at-head table, so a buyer sizing several zones should request the curve and size from it.
Pros: High maximum head and flow figures, stainless motor housing as listed, IP68 rating, maker names irrigation use.
Cons: No flow-at-head table on the page read, voltage and variant need careful confirmation, short cord as listed.
Franklin Electric Series V 25 GPM 1-1/2 HP
- Nominal flow class: 25 GPM, one of four ranges the product page lists from 10 to 25 GPM
- Maximum head for this class and power: 289 ft shut-off, the point where flow reaches zero
- Head at flow: 195 ft at 26 GPM, 264 ft at 17 GPM, as the product page lists for the 25 GPM class at 1-1/2 HP
- Output at 30 PSI: 30 GPM at 80 ft depth to water, 28 at 100 ft, 26 at 120 ft, 24 at 140 ft, 21 at 160 ft, as the product page lists
- Output at 50 PSI: 25 GPM at 80 ft, 23 at 100 ft, 21 at 120 ft, 17 at 140 ft, as the product page lists
- Discharge: 1-1/4 inch NPT
- Motor: Franklin Electric 4 inch submersible motor, assembled, 115/230 V single phase in 2-wire or 3-wire builds as listed
- Construction: thermoplastic or 300 series stainless steel discharge head and motor bracket, removable spring-loaded check valve, as the product page lists
The Series V in its 25 gallon per minute, 1-1/2 HP build is the deep-well planner's pick in this set, because Franklin publishes both curve points and switch-setting output. At 50 PSI, the page lists 21 gallons per minute even at 120 feet to water, which is the sort of figure that keeps a mid-size zone at pressure on a well where shallower-rated pumps have already faded. The maker also notes where its curve readings and printed tables differ slightly on some classes, a level of candour that helps a careful buyer trust the printed output rows used here. Builds come in 2-wire form, which runs without a control box, and 3-wire form, which needs the matched box the page lists by horsepower. The diameter across the cable guard is 3.90 inches as listed, so a true 4 inch casing is the minimum in practice, and the maker sets a maximum water temperature of 120 degrees with proper flow. For a zoned system on a deeper well, this is the model whose published figures let a buyer do the full zone maths without asking for extra documents.
Pros: Published output at both 30 and 50 PSI by depth, strong flow at depth, choice of 2-wire or 3-wire builds, stainless or thermoplastic head options.
Cons: 3-wire builds need a separate matched control box, 3.90 inch diameter leaves little room in a tight 4 inch casing, premium Franklin pricing tier in general retail.
Buying guide
Start with the largest zone, not the whole yard. List the heads in that zone and add the flow each head needs at its rated pressure, using the head maker's chart. Rotors, sprays, and drip lines on the same well often belong in separate zones because their pressures and run times differ, and mixing them forces a compromise pressure that suits none of them well. The zone total, in gallons per minute at the pressure the heads need, is the flow the pump must still deliver after lift and friction. If the largest zone draws more than any candidate pump delivers at the working head, the fix is to split the zone, not to oversize the pump blindly, because an oversized pump cycling against a small zone shortens switch and tank life.
Next, build the total head figure in three parts. Part one is lift: the vertical distance from the pumping water level, which is the level the water drops to while pumping, not the static level and not the pump depth, up to the wellhead. Part two is pressure: multiply the pressure wanted at the tank or at the zone valve, in PSI, by 2.31 to get feet of head. Fifty PSI, a common switch cut-out, is about 116 feet of head on its own, which is why depth plus pressure quickly reaches 200 feet or more. Part three is friction in the drop pipe, main line, fittings, valves, and laterals at the zone flow. Add the three parts, then find that head on each candidate pump's curve and read the flow. The pump fits when the flow at that head meets or modestly exceeds the largest zone.
Read maximum figures with care. Maximum flow is measured at little or no head, and maximum head is the shut-off point where flow reaches zero, so neither number describes watering. A pump listed at 35 gallons per minute and 400 feet will deliver neither figure in a yard; it will deliver some flow between them that only the curve states. This is also why two pumps with the same horsepower can suit different wells. Stage count, impeller design, and the flow class of the water end shape the curve, so a 1-1/2 HP pump built for 25 gallons per minute behaves differently from a 1-1/2 HP pump built for 10 gallons per minute pushed to high head.
Match the discharge and the main line to the flow. Flows in the low twenties and above call for the 1-1/4 inch or 1-1/2 inch discharges these pumps carry, and for main lines sized so friction stays low at zone flow. A long run in an undersized main can add enough friction head to move the working point far down the curve. Where a layout has one distant zone far from the wellhead, size the pump for that zone's total head, not for the nearest zone, or the distant zone will run at low pressure and uneven coverage.
Sort out wiring before ordering. A 2-wire pump, such as the Grundfos SQ models and the 2-wire Franklin builds, runs without a control box and simplifies the install. A 3-wire pump needs its matched control box, which adds a part but puts the starting components above ground where they can be serviced without pulling the pump. Confirm voltage, amp draw, and wire size for the full cable run from the panel to the motor at the setting depth, using the maker's cable table where one is published. Several makers also set a minimum distance off the bottom of the well and above the screen, and those setting rules protect motor cooling, because a submersible motor is cooled by water moving past it.
Think about the well itself as part of the system. The well's yield must meet the zone flow for the full run time, or the pumping level falls, head rises, flow drops, and the pump can draw the well down to its intake. A zone that runs for an hour at 20 gallons per minute needs a well that sustains that rate, not only a pump that can produce it at the starting level. Sand content matters too. Makers describe their sand handling approaches differently, from floating impeller stacks to specific bearing materials, and a sandy well should steer the choice toward the designs whose makers address abrasive wear directly, plus a properly developed well and a setting above the screen.
Finally, plan the controls as a set. A pressure tank sized for the pump's flow reduces starts, a controller sequences zones one at a time so the pump sees a steady load, and a low-water or dry-run safeguard, built in on some models and added separately on others, protects the motor when the well cannot keep up. None of these parts changes the pump curve, but together they decide whether the pump spends its life near its best efficiency point or cycling at the edges of its range. Buy the pump whose published figures fit the largest zone at the real total head, and the rest of the system falls into place around it.
FAQ
How many zones can one of these pumps run?
The pump runs one zone at a time in a standard layout, and the number of zones in total depends on how the yard is divided, not on a zone rating on the pump. What the pump decides is the largest single zone it can feed at pressure. Divide the yard into zones at or below that flow, and the controller can sequence as many zones as the layout needs, provided the well yield sustains the total run time and the pump's starts per hour stay within what the maker allows.
What size pump does a multi-zone lawn system need?
Size by flow at total head, not by horsepower alone. Add the largest zone's flow at its head pressure, convert that pressure to feet at 2.31 feet per PSI, add lift from the pumping water level and pipe friction, then pick a pump whose curve still delivers the zone flow at that head. For many homes that lands in the 20 to 30 gallon per minute classes at 1 to 2 HP, as the models here show, but a shallow well with small zones can need less and a deep well with large rotor zones can need the higher head builds.
Does maximum head tell me how deep my well can be?
Not directly. Maximum head is the shut-off point, where flow reaches zero, so a working well must sit well inside that figure. The pump must lift water from the pumping level and still have head left for pressure and friction while delivering the zone flow. A pump with a 289 foot shut-off, for example, is read on its curve or output table at the actual depth and pressure, where the Franklin figures above list 21 gallons per minute at 120 feet to water on a 50 PSI setting.
Should I choose a 2-wire or 3-wire pump for irrigation?
Both work for zoned systems. A 2-wire pump keeps starting components in the motor and needs no control box, which suits a clean new install. A 3-wire pump uses an above-ground control box, so starting parts can be replaced without pulling the pump from the well. The choice rarely changes the curve; it changes install cost, service access, and which extra parts must be ordered, so decide it alongside the electrical run and who will service the system.
Can a bigger pump damage a zoned system?
A pump far larger than the largest zone can cause short cycling, pressure spikes at valve changes, and flow beyond what laterals were sized for, unless a tank, a pressure regulator, or a drive manages it. Matching the pump to the largest zone with modest headroom is the steadier approach. Where zones vary widely in size, some owners use a cycle stop valve or a variable drive, but those are system decisions to make with the pump curve in hand, not substitutes for sizing.
What well information should I gather before ordering?
Gather the casing diameter, the static water level, the pumping water level at a known flow if a driller's record gives it, the well yield, the depth of the screen or perforations, and any sand or water quality notes. Add the yard figures: the largest zone's head count and flow, the pressure those heads need, and the length and size of the main line. With those numbers, every curve and output table in this article can be applied directly, and a dealer can confirm the final model without guessing.
Conclusion
Multi-zone lawn watering from a well rewards careful reading more than big numbers. The pumps that serve it well publish their flow at pressure and at depth, and the six models here do that to different degrees: the Grundfos 22 SQ15-220 for narrow wells and strong output tables, the Goulds 25GS15 for a serviceable 25 gallon per minute water end, the Red Lion RL22G10-3W2V for a simpler 1 HP install, the Hallmark Industries MA0419X-12A and the VEVOR 2 HP pump for high maximum flow figures on shallower duties, and the Franklin Electric Series V 25 GPM build for deeper wells where output at 50 PSI decides the fit. Work the largest zone's maths, read each curve at the real total head, respect the shut-off point as a ceiling rather than a promise, and the chosen pump will feed its zones in sequence at the pressure the heads were designed for.
Write Your Review
No reviews yet. Be the first to share your experience!