Updated Th11 25, 2026· 18 min read

Key takeaways

  • Compare centrifugal irrigation pumps for moving rainwater between barrels by flow at a stated pressure, listed suction lift, port size, and voltage options.

As an Amazon Associate I earn from qualifying purchases. This post may contain affiliate links at no extra cost to you.

Moving rainwater from a full barrel to an empty one sounds simple until the barrels sit apart, the receiving barrel stands on a raised base, or the water still has to feed a hose or a small irrigation line after the transfer. A hand bucket works for a few gallons. For repeated transfers, a centrifugal irrigation pump placed between the barrels does the carrying, drawing from the source barrel through a suction line and pushing through a discharge line into the receiving barrel. The useful questions are narrow ones: how much flow the maker lists at a stated pressure, how much suction lift the pump lists, what port sizes it uses, and what voltage its motor needs.

That narrow focus shapes this guide to the best centrifugal irrigation pumps for moving rainwater between barrels. None of the picks below earns its place from a headline flow figure alone. Each one is read at a stated pressure and, where the page gives it, at a stated suction lift, because a pump moving water out of a barrel is working against lift on the intake side and against hose length and height on the outlet side. A figure quoted with no pressure attached says little about what arrives at the far barrel.

Rainwater also brings its own conditions. Barrels collect leaf fragments, roof grit, and fine sediment that settles near the bottom, so intake placement and a strainer matter as much as motor size. The pumps below are irrigation and water transfer models with cast iron or stainless housings, listed priming behaviour, and port sizes from 1 inch to 2 inches on the intake. Some are fixed installations that suit a permanent barrel bank. One is a small portable unit that suits moving a modest amount of water and then going back into storage.

Quick verdict

For most barrel-to-barrel setups, the Red Lion RL-SPRK150 is the practical lead pick. The product page lists 71 gallons per minute at 10 PSI and 44 gallons per minute at 30 PSI, a 2-inch intake that suits a short, wide suction line from a barrel, and a dual voltage motor that arrives set for 230 volts and can be switched to 115 volts. The Goulds GT15 IRRI-Gator suits a fixed installation where service access matters, with 63 gallons per minute listed at 20 PSI and a 5-foot suction lift. The Franklin Electric Turf Boss FTB15CI lists a similar output with a back pull-out service design and a shut-off figure stated by lift. The Sta-Rite DS3HF Pro-Storm lists the strongest flow at 20 PSI in this group, at 64 gallons per minute with a 5-foot lift. The Goulds GT20 IRRI-Gator is the step up for longer runs and larger barrel banks, listing 86 gallons per minute at 20 PSI and a 5-foot lift. The Wayne PLS100 is the small, portable option, with output listed in gallons per hour against discharge head rather than in gallons per minute at a pressure.

Product Key spec Best for
Red Lion RL-SPRK150 44 GPM at 30 PSI, 2-inch intake Best for most barrel transfers
Goulds GT15 IRRI-Gator 63 GPM at 20 PSI, 5-foot lift Best for fixed barrel banks
Franklin Electric Turf Boss FTB15CI 65 GPM at 20 PSI, 5-foot lift Best for serviceable fixed setups
Sta-Rite DS3HF Pro-Storm 64 GPM at 20 PSI, 5-foot lift Best for higher head runs
Goulds GT20 IRRI-Gator 86 GPM at 20 PSI, 5-foot lift Best for larger barrel banks
Wayne PLS100 660 gallons per hour at 40 feet of head Best for small portable transfers

How we chose

The first filter was type. Only centrifugal irrigation and sprinkler pumps with a specific model name and a published performance table or performance figures were considered. General utility pumps with no stated flow at a pressure, and models with no listed suction behaviour, were left out, because barrel work depends on both. A pump that cannot draw from a barrel set below or beside it, or that loses its prime whenever it stops, turns a simple transfer into repeated manual work.

The second filter was how the flow figure is stated. Preference went to models where the maker or the product page lists flow at a stated pressure, and ideally at a stated suction lift as well. The Goulds, Franklin Electric, and Sta-Rite tables all pair flow with discharge pressure and suction lift, which lets a reader see output fall as lift rises. The Red Lion page lists flow at 10 PSI and at 30 PSI. The Wayne manual lists output in gallons per hour against discharge head in feet, which is a different way of stating the same trade-off, and it is reported here in that form rather than converted into a pressure figure the maker did not state.

The third filter was priming and lift. Moving water between barrels usually means the pump sits above the water line in the source barrel, at least once that barrel is partly emptied. Models that list self-priming behaviour or reprime capability to a stated lift were favoured for fixed setups. The one portable model in the list does not claim that behaviour, and its section says so plainly: the maker instructs the user to fill the pump and the suction hose before starting, and to use a foot valve to hold prime. That honesty matters more than a long feature list.

Materials and service formed the fourth filter. Rainwater is not harsh, but barrels stand outdoors, pumps sit in damp corners, and grit passes through. Cast iron casings with a corrosion resistant finish, thermoplastic or Noryl impellers, and designs that allow service without cutting the plumbing were favoured. Port size was the fifth filter: a 2-inch intake or a 1.5-inch intake suits a short suction line with less restriction, while a 1-inch portable suits hose work at lower volume. Voltage was the last check, since several of these motors are dual voltage and arrive set for 230 volts, a detail that decides whether the pump runs at all on the supply available.

No model was credited with a fill time for any barrel. Fill time depends on the actual lift, the hose length, the fittings, and how far the source barrel has emptied, none of which a product page can know. The figures below are the listed figures, stated with their conditions, and nothing more.

Red Lion RL-SPRK150

  • Horsepower: 1.5 HP
  • Voltage: 115/230 volts, factory set at 230 volts
  • Flow listed: up to 71 GPM at 10 PSI; 44 GPM at 30 PSI
  • Maximum pressure listed: 44 PSI
  • Intake: 2-inch female NPT; discharge: 1.5-inch female NPT
  • Housing: cast iron; impeller: glass-filled thermoplastic
  • Priming: the product page lists priming to 25 feet and no additional priming after the initial fill
  • Weight listed: 63 pounds

The RL-SPRK150 leads this list because its intake and its priming notes fit barrel work well. A 2-inch intake is wider than the suction port on most of the other models here, and a short, wide suction line is what a barrel setup wants: the pump draws from a bulkhead fitting low on the source barrel or from a reinforced hose dropped over the rim, and a wider line offers less resistance over that short run. The product page lists flow at two pressures rather than a single peak number, so a reader can see the drop from 71 gallons per minute at 10 PSI to 44 gallons per minute at 30 PSI and plan around the lower figure when the receiving barrel stands higher or the hose run is long. The page also states that no additional priming is required after the initial fill, which suits a pump that starts and stops many times across a season of transfers. The dual voltage motor adds flexibility, with the clear warning on the page that the pump voltage must be set to match the source voltage.

Pros: Wide 2-inch intake for a short suction line; flow listed at two pressures; no additional priming listed after the initial fill; dual voltage motor.
Cons: Heavy at 63 pounds, so it suits a fixed spot rather than carrying between barrels; factory voltage setting must be changed for a 115-volt supply; check valve and strainer are not included.

Goulds GT15 IRRI-Gator

  • Horsepower: 1.5 HP, single phase
  • Voltage: 115/230 volts
  • Flow listed: 63 GPM at 20 PSI with a 5-foot suction lift
  • Connections: 1.5-inch NPT suction and 1.5-inch NPT discharge
  • Motor: NEMA standard open drip-proof, 3,500 RPM
  • Casing: cast iron with electro-coat finish; impeller: glass-filled Noryl
  • Reprime capability listed: to 25 feet of suction lift
  • Weight listed: 60 pounds

The GT15 is the fixed installation pick from the IRRI-Gator line. The maker lists capacities for the line to 110 gallons per minute at a 5-foot suction lift and heads to 128 feet, and those are line ceilings rather than this model output. For the GT15 itself, the performance table lists 63 gallons per minute at 20 PSI with a 5-foot lift, falling as lift and pressure rise, which is the honest way to read any barrel transfer: output is strongest while the source barrel is full and the pump sits close to it. The back pull-out design matters in a permanent barrel bank, because the maker lists that servicing can be done without disturbing the suction or discharge piping. The reprime figure also matters here. Once initially primed, the pump is listed as capable of reprime to 25 feet of suction lift, well beyond the depth of any barrel, so the practical limit in this use is keeping the suction line airtight rather than the lift itself.

Pros: Flow listed with both pressure and suction lift; back pull-out service design; reprime capability listed to 25 feet; dual voltage single-phase motor.
Cons: Open drip-proof motor needs shelter from direct weather; 60 pounds suits a fixed mount; output falls as the source barrel empties and lift grows.

Franklin Electric Turf Boss FTB15CI

  • Horsepower: 1.5 HP, single phase
  • Voltage: 115/230 volts
  • Flow listed: 65 GPM at 20 PSI with a 5-foot suction lift; 48 GPM at 40 PSI at the same lift
  • Connections: 1.5-inch FNPT suction and 1.5-inch FNPT discharge
  • Case: cast iron; impeller: modified PPO on the standard build
  • Suction lift listed: self-priming to 25 feet
  • Maximum water temperature listed: 120 degrees F
  • Shut-off listed: 50 PSI at a 5-foot lift

The Turf Boss FTB15CI sits close to the GT15 on listed output and differs mainly in service details and in how completely its table is published. The product page gives a full grid by lift and pressure, so a reader can follow this model from 65 gallons per minute at 20 PSI and a 5-foot lift down to 29 gallons per minute at 20 PSI and a 25-foot lift. For barrel work the shallow end of that grid is the relevant part, and it is strong. The maker lists a back pull-out design that leaves the plumbing, base, and case in place during service, an integral 1-inch NPT priming plug, and a built-in drain plug for winterizing and servicing. That drain plug is a small detail with real value in a barrel system, since the pump and lines need draining before hard freezes. The shut-off figure is stated as a ceiling at a given lift, not as working pressure at the outlet, and it is reported that way here.

Pros: Full published grid by lift and pressure; built-in drain plug for winterizing; back pull-out service design; self-priming lift listed to 25 feet.
Cons: Suction and discharge piping, check valve, and controls are listed as ordered separately; fixed installation weight and size; output drops notably at higher lifts.

Sta-Rite DS3HF Pro-Storm

  • Horsepower: 1.5 HP, single phase
  • Voltage: 115/230 volts, shipped from the factory set at 230 volts
  • Flow listed: 64 GPM at 20 PSI with a 5-foot suction lift; 53 GPM at 30 PSI at the same lift
  • Pipe sizes: 2-inch suction and 1.5-inch discharge
  • Body and seal plate: close-grained cast iron; impeller: Noryl
  • Diffuser: reinforced polypropylene
  • Priming listed: single-body-fill priming to 25-foot lifts
  • Weight listed: 58 pounds

The DS3HF is the pick where the discharge run works against more head, for example when the receiving barrel stands on a raised base or the line climbs to an overhead inlet. The maker describes the Pro-Storm line as high head models, delivering up to 145 feet of head with capacities to 95 gallons per minute across the line, and again those are line figures rather than this model output at a barrel. The model table is the useful part: 64 gallons per minute at 20 PSI with a 5-foot lift, and still 54 gallons per minute at 20 PSI with a 25-foot lift, a smaller drop across lift than several rivals show. Its 2-inch suction matches the Red Lion on intake size, which helps keep the short suction run from a barrel from restricting flow. The maker also lists a drain port for winterizing and service access to normal wearing parts without disturbing piping or mounting.

Pros: Strong flow held across rising suction lift; 2-inch suction port; priming listed to 25-foot lifts; drain port for winterizing.
Cons: Single-phase motors ship set at 230 volts, so the setting must be checked before wiring; cast iron body needs a dry, sheltered mount; line head figures should not be read as this model output.

Goulds GT20 IRRI-Gator

  • Horsepower: 2 HP, single phase
  • Voltage: 230 volts only on the single-phase model
  • Flow listed: 86 GPM at 20 PSI with a 5-foot suction lift; 80 GPM at 30 PSI at the same lift
  • Connections: 1.5-inch NPT suction and 1.5-inch NPT discharge
  • Motor: NEMA standard open drip-proof, 3,500 RPM
  • Casing: cast iron with electro-coat finish; impeller: glass-filled Noryl
  • Reprime capability listed: to 25 feet of suction lift
  • Weight listed: 65 pounds

The GT20 is the step up within the same IRRI-Gator line as the GT15, and it is included for larger barrel banks rather than as a default. Where several barrels are manifolded together and the discharge run is long, the extra listed output gives room for the losses that hose length and fittings add. The maker lists 86 gallons per minute at 20 PSI with a 5-foot lift for this model, and 65 gallons per minute at 40 PSI at the same lift, so it holds flow at higher pressure better than the 1.5 HP models here. That matters when the transfer also has to push water onward into an irrigation line rather than simply into an open barrel. The trade-offs are plain: the single-phase model runs on 230 volts only, it is the heaviest pump in this group alongside its smaller sibling in design, and its capacity is more than a two-barrel setup can use. Buy it for a bank of barrels and a long run, not for a pair of barrels beside a downspout.

Pros: Highest listed flow at 20 PSI in this group; holds 65 GPM at 40 PSI and a 5-foot lift; same service design as the GT15; reprime listed to 25 feet.
Cons: Single-phase model is 230 volts only; oversized for a simple two-barrel transfer; open drip-proof motor needs shelter.

Wayne PLS100

  • Horsepower: 1 HP
  • Power listed: 120 volts, 60 Hz, 15-amp minimum circuit
  • Output listed: 660 gallons per hour at 40 feet of discharge head; 550 at 60 feet; 390 at 80 feet; 210 at 100 feet
  • Suction and discharge: 1-inch NPT each
  • Volute: stainless steel; impeller: thermoplastic
  • Motor: single phase, fan cooled, continuous duty
  • Liquid temperature range listed: 40 to 120 degrees F
  • Priming: the manual instructs filling the pump and suction hose before starting

The PLS100 is the different shape of answer in this list. It is a portable pump for smaller transfers: topping up one barrel from another, moving water to a stock tank, or feeding a single sprinkler after a transfer. Its manual lists output against discharge head in feet rather than pressure, and the figures are modest, 660 gallons per hour at 40 feet of head, which is about 11 gallons per minute in plain arithmetic on the maker stated hourly figure. The manual also sets the placement rules that govern barrel use: keep the vertical distance from the water to the pump as small as possible and not over 20 feet, use a reinforced inlet hose because a regular garden hose can collapse on the suction side, seal every inlet connection against air leaks, and use a foot valve with a strainer to maintain prime. Unlike the self-priming models above, this pump is filled by hand before starting, so it suits occasional transfers rather than an unattended barrel bank. In return it runs on a standard 120-volt supply, carries easily between spots, and stores indoors, which the manual directs for this model.

Pros: Runs on 120 volts; portable and easy to store; stainless steel volute; output listed across a range of discharge heads.
Cons: Much lower output than the 1.5 HP models; not self-priming, so the pump and suction hose are filled before each start after prime is lost; intended for indoor use and storage, with protection needed outdoors.

Buying guide

Start with the suction side, because it decides whether a barrel transfer works at all. The pump has to draw water up and out of the source barrel. Every model above lists a suction lift figure or a placement limit, and all of them are far beyond the depth of a standard barrel when the pump sits beside the barrel at ground level. The real constraint is air. A suction line that leaks at a fitting draws air, loses prime, and drops output, a point both the Red Lion page and the Wayne manual make in their own words. Keep the suction run short, use the full port size rather than reducing it, seal threaded joints, and place the intake low in the barrel with a strainer that keeps leaf fragments and grit out of the impeller.

Next, read flow at a pressure, never as a lone peak. A barrel-to-barrel transfer over a short, level hose run needs little pressure, so a figure at 10 or 20 PSI is the relevant one. A transfer that climbs into a raised barrel, runs through a long hose, or continues into drip lines or sprinklers needs the figure at 30 or 40 PSI instead. Compare models at the same pressure and, where the table gives it, at the same lift. On that basis the 1.5 HP models in this list cluster closely, the GT20 stands apart on output, and the PLS100 belongs to a different, smaller class altogether. Choosing by the largest number on a box, without its pressure attached, is the most common way to buy the wrong pump for this job.

Then consider how the water leaves the source barrel. A bulkhead fitting near the bottom gives the pump a flooded, steady supply and lets the barrel empty almost fully, but it means modifying the barrel. A hose over the rim avoids any modification, yet it adds lift, invites air leaks at the rim bend, and can collapse if the hose is not reinforced on the suction side. The Wayne manual states that collapse risk directly for its pump, and the same physics applies to the larger models. Whichever route is chosen, a foot valve or check valve on the suction or discharge side helps the pump hold its prime between transfers, and several pages above list those parts as separate purchases, so budget the fittings as part of the setup rather than as an afterthought.

Voltage deserves a check before anything is ordered. Three of the fixed models here are dual voltage and arrive set for 230 volts. Run on the wrong setting, a motor will not perform to its listed figures and may be damaged. The GT20 single-phase model has no 115-volt option at all. The PLS100 is the only model here that simply plugs into a standard 120-volt circuit, which is part of its appeal for occasional use. Where a pump will run outdoors or in a damp barrel shelter, follow the maker instructions on grounding and on ground fault protection, keep the motor dry, and shelter open drip-proof motors from direct weather.

Finally, plan for the off season and for sediment. Rain barrels collect fine material that settles, so draw from slightly above the barrel floor rather than from the very bottom, and clean the strainer as part of routine care. Before freezing weather, drain the pump and lines: two models above list a dedicated drain plug or port for exactly this, and the portable model is directed to indoor storage. A pump that is drained, sheltered, and kept primed between uses will do this simple job for a long time, and none of that depends on buying the largest model in the list.

FAQ

Can these pumps empty a rain barrel completely?

Not fully, and no product page above claims otherwise. The intake has to stay submerged and clear of the sediment that settles at the barrel floor, so a small amount of water normally remains below the intake. Drawing from a low bulkhead fitting leaves less behind than a hose over the rim, but planning for a shallow remainder is more realistic than expecting a dry barrel.

Does the pump need to sit below the barrel?

No. The fixed models list self-priming behaviour or reprime capability to a stated lift, and the portable model lists a maximum vertical distance from the water. A pump beside the barrel at ground level works within all of those listed figures. What matters more is a short, airtight suction line, since air leaks, not a few feet of lift, are the usual cause of lost prime in this setup.

How long will a transfer between two barrels take?

No fill time is stated here, because no maker lists one for this use and the real time depends on lift, hose length, fittings, and how far the source barrel has emptied. The listed flow at a stated pressure gives a planning figure only: output at the start of a transfer, with a full source barrel and a short lift, will be higher than output near the end. Use the flow figure at the pressure closest to the actual run, and treat it as a guide to scale rather than a promise of minutes.

Is a 2-inch intake better than a 1.5-inch intake for barrels?

On a short suction run, a wider intake offers less resistance, and two models above list a 2-inch suction port. The benefit is real but modest at barrel distances. Port size matters more when the discharge run is long or the pump also feeds sprinklers. Matching the suction line to the full port size, without reducing it, matters more than the difference between these two sizes.

Can one of these pumps feed sprinklers after the transfer?

Several can, because they are sprinkler and irrigation pumps by design. The Red Lion page lists sprinkler head counts per zone at its stated pressures, and the Goulds, Franklin Electric, and Sta-Rite models are listed for lawn sprinkling and irrigation as well as water transfer. Check the flow at the pressure the sprinkler needs, not the flow at 10 PSI, and expect the barrel to empty far faster than it would through a barrel-to-barrel hose run.

What protection does rainwater grit need?

A strainer on the intake is the main answer, and the pages above point that way: the Red Lion instructions call for a strainer on the intake line, and the Wayne manual calls for a foot valve with a strainer and clear water free of sand, dirt, and scale. Keep the intake off the barrel floor, rinse the strainer when flow drops, and do not run any of these pumps dry.

Conclusion

Moving rainwater between barrels is a modest job that rewards modest, well-read specifications. The Red Lion RL-SPRK150 suits most setups with its wide intake, its flow listed at two pressures, and its priming behaviour after the initial fill. The Goulds GT15, Franklin Electric FTB15CI, and Sta-Rite DS3HF each suit a fixed barrel bank in slightly different ways: service access, a built-in drain, and stronger flow across lift. The Goulds GT20 is the choice only where a larger bank and a longer run justify its output and its 230-volt requirement. The Wayne PLS100 covers the small, occasional transfer and stores away afterwards. Whichever model is chosen, the result depends less on the motor than on the suction line: short, full-sized, airtight, and fitted with a strainer. Get that side right, read the flow figure at its stated pressure, and the transfer becomes the simple job it should be.

A
admin88
We compare specs, warranty terms, long-term owner feedback and street pricing before anything earns a spot. Rankings are never paid.
Affiliate disclosure. As an Amazon Associate we earn from qualifying purchases at no extra cost to you. Prices accurate as of the date shown.

Related guides

Browse all pumps guides →