Updated Th11 24, 2026· 14 min read

Key takeaways

  • Compare the best water pumps for 5 well casings, with 4-inch-class submersible models from Myers, Sta-Rite, Franklin Electric, Flint and Walling and VEVOR.

As an Amazon Associate I earn from qualifying purchases. This post may contain affiliate links at no extra cost to you.

A 5-inch well casing sounds roomy until the pump has to share it. A standard 4-inch-class submersible pump measures about 3-7/8 inches across, which leaves roughly an inch and an eighth of open ring inside a 5-inch casing. That ring has to carry the power cable and its guard, the torque arrestor, and, most importantly, a steady flow of water moving up past the motor so the motor stays cool. Pick a pump that is too fat, too long for the setting depth, or mismatched to the well's yield, and the installation fights you at every step. This guide compares the best water pumps for 5 wellcasings on the figures that decide that fit: outside diameter, flow class, horsepower, stage count, wiring, and the materials the maker lists for the wet end.

All five picks are 4-inch-class submersibles in the 10-gallon-per-minute household class, apart from one high-flow outlier that suits shallow, high-yield wells. Four of them come from established American pump brands with published data sheets, and one is a value import sold under its maker's model number. Where sources disagreed on a figure, the maker's own data sheet or manual won, and the disputed number was left out.

The shared theme is clearance discipline. Every pump here is at or under 4 inches in diameter, so each one leaves a working annulus in a 5-inch casing for cooling flow and hardware. The differences are in how each maker builds the pump: floating impellers against fixed staging, two-wire against three-wire motors, and stainless shells against engineered thermoplastic.

Quick verdict

For most 5-inch casings, the Myers Predator Plus 2ST102-12PLUS-P4 is the balanced pick: a 1-horsepower, 13-stage, two-wire pump in the 10-to-12-gallon class with a stainless shell and a floating impeller design that tolerates sand. The Sta-Rite HS Series S10P4HS10221 is its closest rival, with the same SignaSeal staging system in a slightly shorter body. The Franklin Electric 3200 Series is the pick when clearance is tightest, because its reduced 3.75-inch diameter is the slimmest here. The Flint and Walling 4F10S10301 suits owners who prefer a three-wire motor with an above-ground control box. The VEVOR 4SSM5/8 is the high-flow option for shallow wells, moving far more water per minute but filling the casing almost completely.

Comparison table

Product Key spec Best for
Myers Predator Plus 2ST102-12PLUS-P4 3-7/8 in diameter, 1 HP, 13 stages, 2-wire Most 5-inch casings needing a sand-tolerant 10 GPM pump
Sta-Rite HS Series S10P4HS10221 3-7/8 in diameter, 1 HP, 13 stages, 28-3/4 in long Installations wanting a shorter pump body
Franklin Electric 3200 Series (10 GPM, 1 HP) 3.75 in diameter, 618 ft shut-off head Tight casings and deeper settings
Flint and Walling 4F10S10301 Commander S 3-7/8 in diameter, 1 HP, 3-wire, 470 ft max depth Owners who prefer an external control box
VEVOR Deep Well Pump 4SSM5/8 4 in diameter, 1.5 HP, 37 GPM max flow Shallow, high-yield wells needing volume

How we chose

The first filter was diameter. A pump for a 5-inch casing must be a 4-inch-class unit or smaller, and the maker's stated diameter had to come from a data sheet, catalog, or manual page that could be opened and read, not from a roundup. Every pick below states its diameter in its own literature: 3-7/8 inches for the Myers, Sta-Rite, and Flint and Walling, 3.75 inches for the Franklin Electric, and a full 4 inches for the VEVOR.

The second filter was a published performance identity: a named flow class, horsepower, stage count, and voltage, so the pump can be matched to a well's depth and yield on paper before anyone lowers it into the casing. Pumps whose listings gave only marketing language, with no data sheet or manual behind them, were dropped.

The third filter was construction detail. Submersible pumps live or die by their staging and bearings, so each pick had to state its impeller and diffuser materials, its discharge size, and its motor type. All five discharge through a 1-1/4 inch NPT outlet, which keeps the comparison honest: the differences are in diameter, wiring, staging design, and flow, not in plumbing.

Finally, models already used in the sibling guide to pumps for 5-inch well casings were excluded, so this list is built from a different set of pumps: no Grundfos SQ, no Goulds GS, no Red Lion RL series, and no Hallmark models appear here.

Myers Predator Plus 2ST102-12PLUS-P4

  • Diameter: 3-7/8 in
  • Flow class: 10 to 12 GPM class, 1 HP
  • Stages: 13
  • Wiring: 2-wire, 230 V
  • Length and weight: 29 in assembled, 35 lb
  • Shell, discharge and intake: stainless steel
  • Impellers and diffusers: acetal impellers, polycarbonate diffusers
  • Motor: Pentek XE
  • Discharge: 1-1/4 in NPT

The Predator Plus is Pentair's sand-handling household submersible, and its data sheet leads with the SignaSeal staging system: a ceramic wear surface paired with a floating impeller design, so the acetal impellers can move slightly instead of grinding against the diffusers when the well produces fine sand. In a 5-inch casing that matters twice over, because a pump that tolerates grit keeps its clearances, and clearances are what the cooling flow depends on. The series behind this model spans heads to 1,950 feet and capacities to 65 gallons per minute, and this build sits in the middle of it: 1 horsepower, 13 stages, two-wire 230-volt power, so no control box is needed at the surface.

At 29 inches long and 35 pounds, it is a manageable one-person lower with a helper at the wellhead, and the stainless shell, discharge head, and intake screen suit wells where corrosion has marked older pumps. The maker lists the pump as CSA listed. For a typical 5-inch casing serving a house, this is the specification sheet that asks the fewest compromises.

Pros:

  • Floating impeller SignaSeal staging tolerates sandy water
  • Two-wire motor removes the surface control box
  • Stainless shell, discharge, and intake

Cons:

  • Mid-length body at 29 in needs a straight casing run
  • Two-wire design means motor starting gear is down the well

Sta-Rite HS Series S10P4HS10221

  • Diameter: 3-7/8 in
  • Flow class: 10 GPM, 1 HP
  • Stages: 13
  • Wiring: 2-wire, 230 V
  • Length and weight: 28-3/4 in, 34-1/2 lb
  • Shell: stainless steel
  • Staging: SignaSeal with acetal impellers
  • Motor: Pentek XE
  • Discharge: 1-1/4 in NPT

The Sta-Rite HS Series, sold under the Signature 2000 Stainless name, shares its core technology with the Myers above: the same SignaSeal staging, the same acetal impellers, and the same Pentek XE motor family, because both brands sit inside the same Pentair stable. The S10P4HS10221 build is a 10-gallon-per-minute, 1-horsepower, 13-stage, two-wire pump, and its distinguishing figure is length: at 28-3/4 inches it is the shortest of the three Pentair-style pumps here, a quarter inch shorter than the Myers and noticeably easier to swing into a casing with a tight pitless arrangement.

The stainless shell is the other half of its identity. Sta-Rite positions the HS line as its corrosion-resistant household series, and the data sheet keeps the specification tight: 3-7/8 inch diameter, 34-1/2 pounds, 1-1/4 inch NPT discharge. Owners choosing between this and the Myers are really choosing between two near-identical data sheets from sister brands; availability and the installing dealer's preference usually settle it, and either pump leaves the same healthy annulus in a 5-inch casing.

Pros:

  • Shortest body of the Pentair-style picks at 28-3/4 in
  • SignaSeal staging with acetal impellers
  • Stainless shell for corrosion-prone wells

Cons:

  • Specification nearly identical to the Myers, so cross-shopping saves little
  • Two-wire motor, so no surface control box option

Franklin Electric 3200 Series (10 GPM, 1 HP build)

  • Diameter: 3.75 in, including the cable guard
  • Flow class: 10 GPM, 1 HP
  • Shut-off head: 618 ft
  • Stages: 19 in the plastic 2-wire build per the maker brochure
  • Wiring: 2-wire or 3-wire, 115 V or 230 V
  • Length and weight: 35.2 in, 36 lb in the brochure build
  • Bearing: hex rubber bearing with ceramic shaft sleeve
  • Discharge: 1-1/4 in NPT

The 3200 Series is Franklin Electric's answer to a specific problem: casings where a standard 3-7/8 inch pump is a tighter squeeze than the installer wants. Every part of the pump end, cable guard included, stays within the motor diameter, giving a true 3.75-inch maximum. In a 5-inch casing that buys an extra eighth of an inch of annulus all the way around, which is meaningful room for the cable and for cooling flow in a casing that is slightly out of round or carrying mineral scale.

The trade is length: the 10-gallon, 1-horsepower build runs 19 stages and about 35.2 inches overall, the longest pump in this guide, and its shut-off head of 618 feet is the deepest rating here. The floating stage design uses an acetal impeller with a modified PPO diffuser, a removable spring-loaded check valve, and a hex rubber bearing with a ceramic shaft sleeve. The maker rates it for water up to 120 degrees Fahrenheit and lists UL 778, CSA, and NSF 61 and 372 compliance. Deep, slightly tight 5-inch casings are exactly its home ground.

Pros:

  • Slimmest diameter here at 3.75 in, cable guard included
  • Deepest shut-off head in the group at 618 ft
  • Both 2-wire and 3-wire builds offered

Cons:

  • Longest pump here at about 35.2 in
  • Length demands a straight, unobstructed casing

Flint and Walling 4F10S10301 Commander S

  • Diameter: 3-7/8 in maximum
  • Flow class: 10 GPM class, 1 HP
  • Wiring: 3-wire, 230 V, about 8.2 A
  • Performance point: 13 GPM at 100 ft of head
  • Maximum depth: 470 ft
  • Body: stainless steel
  • Impellers: Noryl
  • Discharge head: 1-1/4 in NPT, 304 stainless steel
  • Control box: required, sold separately

Flint and Walling builds the Commander S series in Indiana, and the 4F10S10301 is the traditionalist's pick in this group: a three-wire, 1-horsepower pump in the 10-gallon class that pairs with a surface control box, so the starting components live in the basement or pump house where they can be serviced without pulling the pump. The maker's catalog gives the series a 3-7/8 inch maximum diameter and a 304 stainless discharge head, and retailer specification pages for this model list a stainless body with Noryl impellers, a draw of about 8.2 amps at 230 volts, and a maximum setting depth of 470 feet.

Its published performance point, 13 gallons per minute at 100 feet of head, shows a pump that runs slightly above its nominal class at moderate depths, which suits 5-inch casing wells with a high static water level. The three-wire layout is the deliberate difference from the two-wire pumps above: one more conductor down the well, in exchange for a control box that a service technician can open, test, and replace in minutes.

Pros:

  • Three-wire design puts starting gear in a serviceable surface box
  • Stainless body and 304 stainless discharge head
  • Strong published point of 13 GPM at 100 ft

Cons:

  • Control box is a separate purchase
  • Three-wire cable run costs more than two-wire

VEVOR Deep Well Submersible Pump 4SSM5/8

  • Diameter: 4 in
  • Power: 1.5 HP, 1100 W, 230 V, 60 Hz
  • Maximum flow: 37 GPM
  • Maximum head: 276 ft
  • Stages: 8, thermoplastic impellers
  • Discharge: 1-1/4 in NPT
  • Cord: 33 ft
  • Rating: IP68, ETL listed, 3,450 rpm
  • Check valve: built in; external control box

The VEVOR is the outlier and should be chosen deliberately. Its 4-inch diameter is the largest here, and the maker's own manual states it suits casings of 4 inches or larger, which in a 5-inch casing leaves the slimmest annulus of any pick: about half an inch per side for the cable and cooling flow. In exchange it moves a great deal of water, up to 37 gallons per minute against a maximum head of 276 feet, from a 1.5-horsepower motor turning eight thermoplastic impeller stages. That profile fits a shallow, high-yield 5-inch well feeding irrigation or a large household draw, where the water level is high and the pump does not need depth.

The construction is stainless steel with an IP68 rating, a built-in check valve, and an external control box, and the maker lists ETL certification. The 33-foot factory cord is short for deeper settings and will usually need a proper splice kit. Treat this pump as a volume tool for shallow wells, and confirm the casing is clean and true before choosing the tightest fit in the group.

Pros:

  • Highest flow here at up to 37 GPM
  • Stainless body, IP68 rating, built-in check valve
  • 1.5 HP motor for shallow, high-demand wells

Cons:

  • Full 4 in diameter leaves the least cooling room in a 5 in casing
  • 276 ft maximum head rules out deep settings
  • Short 33 ft cord usually needs a splice

Buying guide

Start with the casing, not the pump. Measure or confirm the casing's true inside diameter and check for scale, a slightly oval section, or a repair coupling that narrows the bore. A nominal 5-inch casing in good condition accepts any pump in this guide; a scaled or dented one argues for the Franklin Electric 3200 Series and its 3.75-inch profile. Remember that the pump is not the only thing in the hole: the cable, cable guard, torque arrestor, and safety rope all share the annulus, and the motor needs water moving past it whenever it runs. The wider the leftover ring, the more forgiving the installation.

Match the pump to the well next. The setting depth, the static and pumping water levels, and the well's recovery rate decide the head and flow the pump must deliver. A 10-gallon-per-minute class pump with a shut-off head above 600 feet, like the Franklin build, covers deep household wells. A pump rated to 470 feet, like the Flint and Walling, covers most mid-depth wells. The VEVOR's 276-foot ceiling and 37-gallon flow only make sense where the water is shallow and plentiful; a high-flow pump in a low-yield well will cycle, draw the level down to the intake, and shorten its own life.

Choose the wiring deliberately. Two-wire pumps, the Myers, Sta-Rite, and the two-wire Franklin build, keep the starting components inside the motor: simpler cable, no box on the wall, but any starting failure means pulling the pump. Three-wire pumps, the Flint and Walling and the VEVOR pattern, move those components into a surface control box that can be opened and swapped in minutes. Neither is better in the abstract; the choice is between installation simplicity and service access.

Read the staging materials for your water. Sandy wells favor floating impeller designs with hard wear surfaces, the SignaSeal pattern shared by the Myers and Sta-Rite, or Franklin's floating stages. Corrosive water favors stainless shells and discharge heads. Every pump here discharges through 1-1/4 inch NPT, so the drop pipe and pitless adapter sizing stays constant across the group.

Finally, plan the whole string before ordering: pump, cable sized to the motor's amp draw and run length, a torque arrestor, check valve arrangement, and a pressure tank and switch matched to the flow class. A correctly sized pump in a 5-inch casing should run in long, calm cycles, not short bursts.

FAQ

Will a 4-inch pump overheat in a 5-inch casing?

The opposite arrangement is the concern. A 4-inch-class pump in a 5-inch casing has water flowing up past the motor whenever the pump runs, which is the cooling path these motors are built around. Overheating risk rises when a pump nearly fills its casing, as the 4-inch VEVOR does here, or when flow past the motor is blocked. Keeping the annulus clear and the intake unobstructed is what protects the motor.

How much clearance does a pump need around it?

There is no single figure every maker publishes, but the working logic is visible in this guide: standard 4-inch-class pumps measure 3-7/8 inches, leaving about 1-1/8 inches of total ring in a 5-inch casing for the cable, guard, torque arrestor, and cooling flow. The Franklin 3200 Series trims that to 3.75 inches for casings that are scaled or out of round. If a casing cannot accept a 3-7/8 inch pump with its cable guard fitted, the reduced-diameter design is the safer choice.

Should I choose a 2-wire or 3-wire pump?

Choose 2-wire for a simpler installation: the Myers, Sta-Rite, and two-wire Franklin builds need no surface control box. Choose 3-wire, like the Flint and Walling 4F10S10301, when service access matters, because the starting components sit in a box that can be opened and replaced without pulling the pump from the well. Both patterns are long-established; the motors in this guide are built for one pattern or the other, so decide before ordering cable.

What flow rate does a house on a 5-inch casing need?

Most houses run well on the 10-gallon-per-minute class that four of these five pumps occupy, provided the well itself can sustain that rate. The well's yield is the ceiling: a pump should be sized at or below what the well recovers. The VEVOR's 37-gallon maximum suits irrigation or unusually high demand from a strong, shallow well, not a typical household draw, and fitting it to a weak well invites drawdown and cycling.

How deep can these pumps be set?

The deepest rating here is the Franklin 3200 build's 618-foot shut-off head, followed by the Flint and Walling's 470-foot maximum depth. The VEVOR stops at 276 feet of head. Shut-off head is the absolute ceiling at which flow falls to zero, so the working setting should sit comfortably below it, with the pump's published curve checked against the well's total dynamic head.

Do I need a flow sleeve in a 5-inch casing?

A flow sleeve, also called a shroud, is used when water enters the well above the pump or the casing is much larger than the pump, so flow past the motor cannot be assumed. In a standard 5-inch casing with the pump set below the water's entry points, the natural upflow usually does the job. If the well's perforations sit above the pump, a sleeve is cheap insurance for any model in this guide.

Conclusion

A 5-inch casing rewards the standard 4-inch-class pump: enough room for cable and cooling flow, and a wide choice of proven designs. The Myers Predator Plus 2ST102-12PLUS-P4 is the default recommendation for its sand-tolerant floating staging and simple two-wire layout, with the Sta-Rite S10P4HS10221 a near-identical alternative in a shorter body. Tight or scaled casings point to the reduced-diameter Franklin Electric 3200 Series, service-minded owners to the three-wire Flint and Walling 4F10S10301, and shallow, high-yield wells to the high-flow VEVOR 4SSM5/8. Measure the casing, respect the well's yield, and any of the five will run cool and steady in the space a 5-inch casing gives it.

A
admin88
We compare specs, warranty terms, long-term owner feedback and street pricing before anything earns a spot. Rankings are never paid.
Affiliate disclosure. As an Amazon Associate we earn from qualifying purchases at no extra cost to you. Prices accurate as of the date shown.

Related guides

Browse all pumps guides →