  • Six centrifugal irrigation pumps compared for filling raised garden tanks, with listed head, flow at working pressure, suction lift, ports and motor notes.

As an Amazon Associate I earn from qualifying purchases. This post may contain affiliate links at no extra cost to you.

Filling a raised garden tank looks simple from the ground. A hose goes up, water goes in, and the tank is ready to feed beds and rows by gravity later. The pump doing that work faces a harder job than a pump feeding sprinklers on flat ground, because every foot of height between the water source, the pump, and the tank inlet adds to the load. A pump that moves a strong stream across a lawn may slow to a thin trickle when it has to push water upward into a tank, and a pump chosen only for its highest flow figure may leave a large tank filling far longer than planned.

That is why this guide to the best centrifugal irrigation pumps for filling elevated garden tanks starts with head, not with horsepower alone. Head is the height, expressed in feet, that a pump can push water against. Flow is how much water moves in a given time, usually listed in gallons per minute. The two figures work against each other: as the required head rises, the flow a centrifugal pump delivers falls. The makers publish both figures, and the useful reading is not the largest number on the page. The useful reading is the flow the product page lists at the pressure or lift that matches your own tank, pipe run, and source.

Six pumps are covered here, all true centrifugal irrigation models from established pump lines. They include three sizes from the Goulds GT IRRI-Gator line, a Franklin Electric Turf Boss model, a Sta-Rite Pro-Storm DS3 model, and a Red Lion sprinkler pump model. Each one is a specific model, with its own listed motor size, port sizes, flow figures, and head or pressure limits. Read the sections in order if you are sizing a system from scratch, or go straight to the model whose listed head range fits a tall tank stand and a long pipe run.

Quick verdict

For most raised tank setups with a moderate rise, the Goulds GT15 offers a balanced set of listed figures: a 1.5 horsepower motor, a listed maximum flow of 64 gallons per minute, and a listed shut-off head of 121 feet. That shut-off figure is a ceiling, not a working flow point, and the section below explains what it means in practice. For a taller stand or a longer uphill run, the Goulds GT20 and the Sta-Rite DS3HF give higher listed flow at working pressure, while the Franklin Turf Boss FTB2CI lists strong flow at higher discharge pressures. The Goulds GT10 is the smaller option for a shorter rise and a smaller tank. The Red Lion RL-SPRK200 is the wide-port option, with a 2 inch intake that suits a large suction line from a pond, cistern, or ground level storage tank.

None of these pumps should be chosen from the headline flow alone. Match the tank height, the suction lift from the source, and the friction in the pipe run against the flow each maker lists at a stated pressure or lift. A pump with room to spare in its listed head range will fill a tank in a steady, predictable way. A pump working right at the top of its range will fill it slowly, and may not fill it at all if the figures were read too loosely.

Product Key spec Best for
Goulds GT15 IRRI-Gator 1.5 HP, 64 GPM maximum flow, 121 ft shut-off head Raised tanks with a moderate rise
Goulds GT20 IRRI-Gator 2 HP, up to 86 GPM at 20 PSI and 5 ft lift Larger tanks and longer uphill runs
Goulds GT10 IRRI-Gator 1 HP, up to 53 GPM at 20 PSI and 5 ft lift Smaller tanks with a shorter rise
Franklin Electric Turf Boss FTB2CI 2 HP, 70 GPM at 20 PSI and 5 ft lift Tank filling that also feeds pressurised lines
Sta-Rite DS3HF Pro-Storm 1.5 HP, 64 GPM at 20 PSI and 5 ft lift Setups needing a 2 inch suction port
Red Lion RL-SPRK200 2 HP, 76 GPM maximum flow, 49 PSI maximum pressure Large suction lines from ponds or cisterns

How we chose

The starting point was type. Only centrifugal irrigation pumps were considered, because that is the pump type named in the topic and the type built for moving larger volumes of water for lawn and garden irrigation, water transfer, and tank filling. Jet pumps, submersible well pumps, small utility pumps, and battery transfer pumps were left out, even when their listings used irrigation language. A model had to be a named, specific product in a current pump line, not a generic listing with no model number.

The second filter was listed head and pressure information. Filling a raised tank is a head task before it is a flow task, so a model needed published figures that let a reader judge the upward push: a shut-off head, a maximum head for the line, a maximum pressure, or flow figures stated at set discharge pressures and suction lifts. Models with only a single maximum flow figure and no pressure or lift context were passed over, because that single figure says little about filling a tank set above the pump.

The third filter was the suction side. Many gardeners draw from a ground level source such as a pond, a cistern, a shallow well, or a lower storage tank, then push up to the raised tank. The product page lists a suction lift figure for each model here, and most list a self-priming design. Priming was not treated as a requirement in the automatic sense. Each model still needs a correct first fill and a suction line that holds water, and the individual sections note where the maker describes that first prime. What mattered was that the listed lift gave enough room for a source set below the pump.

Construction and service points were the fourth filter. Cast iron casings appear across this group, along with named impeller materials such as glass-filled Noryl, modified PPO, and thermoplastic. Back pull-out service designs appear on the Goulds and Franklin models, which means the maker lists servicing without disturbing the pipework. Port sizes were recorded exactly as listed, because a 2 inch suction port and a 1.5 inch suction port lead to different plumbing plans.

Finally, every figure in this article comes from a product page or maker document for that exact model. Flow figures are quoted with the pressure or lift the maker attaches to them. Where a maker lists a maximum head, that figure is described as a ceiling. At or near the ceiling, flow falls toward zero, so a working tank fill needs a pump whose listed range sits comfortably above the total head of the installation.

Goulds GT15 IRRI-Gator

  • Horsepower: 1.5 HP, single phase
  • Voltage: 115/230 volts, listed at 21.6/10.8 amps
  • Maximum flow: 64 gallons per minute
  • Shut-off head: 121 feet
  • Flow at head: 63 GPM at 5 feet of head, 59 GPM at 10 feet, 54 GPM at 15 feet, 49 GPM at 20 feet, 39 GPM at 25 feet
  • Suction and discharge: 1.5 inch NPT on both sides
  • Casing: cast iron; impeller: Noryl; seal: carbon-ceramic mechanical seal
  • Motor: open drip-proof, 48J frame, built-in thermal overload protection
  • Maximum water temperature: 140 degrees F

The GT15 sits in the middle of the Goulds GT line, and its listed figures suit a raised tank of moderate height fed from a source near the pump. The product page lists a maximum flow of 64 gallons per minute and a shut-off head of 121 feet. Shut-off head is the point at which the pump pushes against so much resistance that flow stops, so 121 feet is a ceiling for the model, not a height at which it delivers 64 gallons per minute. The flow-at-head figures on the same page make the real picture clearer: flow holds at 63 gallons per minute at 5 feet of head, then steps down as head rises, reaching 39 gallons per minute at 25 feet of head. A tank inlet 15 or 20 feet above the pump, plus pipe friction, still leaves useful flow on those listed figures.

The maker describes the GT line as self-priming, single-stage centrifugal pumps for lawn sprinkling and general water transfer, with a cast iron casing and a back pull-out design for servicing without disturbing the piping. For tank filling, that service point matters over several seasons, because a pump that fills a tank daily through a growing season will need its seal and impeller inspected at some point. The 1.5 inch ports on both sides keep the plumbing simple, and the dual voltage motor gives a choice of supply where a 230 volt circuit is not already in place near the tank.

Pros: Listed flow stays strong through the head range most raised tanks need; dual voltage motor; cast iron casing with back pull-out service design
Cons: Heavy cast iron build needs a firm, level base; 230 volt running gives the listed amp draw its lower figure, so wiring should be planned before purchase

Goulds GT20 IRRI-Gator

  • Horsepower: 2 HP, single phase
  • Voltage: 230 volts, listed at 13.9 full load amps
  • Flow: up to 86 GPM at 20 PSI with a 5 foot suction lift; up to 80 GPM at 30 PSI and 65 GPM at 40 PSI on maker performance figures for the line
  • Line capacities: heads to 128 feet for the GT line, maximum working pressure 125 PSI
  • Suction and discharge: 1.5 inch NPT on both sides
  • Casing: cast iron with electro-coat finish; impeller: glass-filled Noryl
  • Motor: NEMA standard 3500 RPM open drip-proof, built-in overload with automatic reset on single-phase models
  • Weight: 65 pounds listed for the GT20

The GT20 is the step up in the same Goulds line for a larger tank, a taller stand, or a longer run of pipe between source and tank. The maker lists up to 86 gallons per minute at 20 PSI with a 5 foot suction lift for the 2 HP model, compared with up to 63 gallons per minute for the 1.5 HP model at the same stated point. That gap is the reason to choose this size: at a working pressure, rather than at a headline maximum, the GT20 moves more water, so a big tank spends less time filling and the pump spends less time running per fill.

The line figure of heads to 128 feet needs the same careful reading as the GT15 shut-off figure. It marks the top of the range for the line, a ceiling where flow is minimal, not a promise of strong flow at that height. The working decision should rest on the flow at 20, 30, and 40 PSI. If a tank stand, a slope, and pipe friction together call for pressure near the top of that stated range, the listed flow at 40 PSI is the figure to plan around. The GT20 runs on 230 volts only in single phase, so the electrical plan is simpler but less flexible than the smaller dual voltage models. A dedicated circuit near the pump location is part of the installation, not an afterthought.

Pros: Highest listed flow at working pressure in the Goulds group here; same 1.5 inch ports as the smaller GT models; built-in overload with automatic reset listed for single-phase models
Cons: 230 volt only in single phase; heaviest of the three Goulds models listed here, at 65 pounds

Goulds GT10 IRRI-Gator

  • Horsepower: 1 HP, single phase
  • Voltage: 115/230 volts, listed at 16/8 full load amps
  • Flow: up to 53 GPM at 20 PSI with a 5 foot suction lift
  • Line capacities: heads to 128 feet for the GT line; capacities to 110 GPM at 5 foot suction lift across the line
  • Suction and discharge: 1.5 inch NPT on both sides
  • Casing: cast iron with electro-coat finish; impeller: glass-filled Noryl
  • Motor: NEMA standard 3500 RPM open drip-proof
  • Weight: 52 pounds listed for the GT10
  • Maximum working pressure: 125 PSI for the line

The GT10 is the smallest of the three Goulds models in this guide, and it fits the smaller end of the raised tank job: a modest tank on a low stand, a short pipe run, and a source close to the pump. The maker lists up to 53 gallons per minute at 20 PSI with a 5 foot suction lift for the 1 HP model. For a tank of a few hundred gallons with a short rise, that listed flow fills in a reasonable run time without moving up to a larger motor and a heavier unit.

The limits should be read plainly. With less flow at working pressure than the GT15 or GT20, the GT10 has less room when the tank is tall, the run is long, or friction losses grow because of elbows and smaller pipe. It shares the same 1.5 inch suction and discharge ports, the same cast iron casing approach, and the same self-priming design description as its larger siblings, so the plumbing plan and service approach carry across the line. The dual voltage motor is a practical point for a garden building or outbuilding where the available supply may be 115 volts. Choosing the GT10 is a sizing decision, not a compromise on type: it is the right scale when the total head of the system is genuinely low.

Pros: Dual voltage motor suits more garden power supplies; same ports and casing style as the larger GT models; lightest Goulds model in this guide
Cons: Lowest listed flow at working pressure in this guide; less head room for tall stands or long runs

Franklin Electric Turf Boss FTB2CI

  • Horsepower: 2 HP, single phase
  • Voltage: 230 volts
  • Flow at 5 foot suction lift: 70 GPM at 20 PSI, 69 GPM at 25 PSI, 69 GPM at 30 PSI, 68 GPM at 35 PSI, 65 GPM at 40 PSI, 53 GPM at 45 PSI, 35 GPM at 50 PSI
  • Shut-off pressure: 52 PSI at a 5 foot lift, 45 PSI at a 25 foot lift
  • Suction lift: up to 25 feet listed for the self-priming design
  • Suction and discharge: 1.5 inch FNPT on both sides
  • Case: cast iron; hydraulic components: modified PPO, with a stainless steel impeller version in the line
  • Speed: 3600 RPM; maximum water temperature: 120 degrees F
  • Service: back pull-out design; integral 1 inch NPT priming plug and built-in drain plug

The Turf Boss FTB2CI stands out in this group for how flat its listed flow curve stays as pressure rises. At a 5 foot suction lift, the maker lists 70 gallons per minute at 20 PSI and still lists 65 gallons per minute at 40 PSI, with flow holding into the higher pressure steps before falling at 50 PSI. For tank filling, that shape matters when the tank inlet is high and the system also needs pressure at the end of the fill, for example where the same pump feeds a raised tank and a pressurised line at different times. The flow does not fall away early, so the fill rate near the top of a tall tank stays closer to the rate at the start.

The shut-off pressure figures set the ceiling for this model: 52 PSI at a 5 foot lift, falling to 45 PSI at a 25 foot lift. Those are the points where flow stops, so a system whose total requirement sits near those pressures is beyond a sensible working range for this pump. Within range, the cast iron case, the back pull-out service design, and the built-in drain plug suit a permanent installation near a tank stand. The maker lists the Turf Boss line for lawn sprinkler systems and for moving water from a lake, pond, or cistern, which matches the common raised tank pattern of drawing from a low source and pushing upward. Water temperature is capped at 120 degrees F in the listing, lower than the Goulds figure, which matters only where sun-heated source water sits in dark storage through hot weather.

Pros: Listed flow holds up well at higher discharge pressures; back pull-out service design; priming plug and drain plug built in
Cons: 230 volt only in this size; listed maximum water temperature of 120 degrees F is the lowest in this guide

Sta-Rite DS3HF Pro-Storm

  • Horsepower: 1.5 HP, single phase
  • Voltage: 115/230 volts, factory set at 230 volts for single-phase motors in the series document
  • Flow: 64 GPM at 20 PSI with a 5 foot suction lift; 53 GPM at 30 PSI; 35 GPM at 40 PSI
  • Series head: high head models in the DS3 document deliver up to 145 feet of head with capacities to 95 GPM across the series
  • Priming: single-body fill priming to 25 foot lifts, listed at less than 5 minutes in the series document
  • Suction: 2 inch; discharge: 1.5 inch
  • Body and seal plate: close-grained cast iron; impeller: Noryl; diffuser: reinforced polypropylene
  • Shaft: one-piece threaded 300 grade stainless steel; base: 10 gauge steel
  • Weight: 58 pounds listed for the DS3HF

The DS3HF brings a different port layout to the group. The series document lists a 2 inch suction tapping and a 1.5 inch discharge tapping for this 1.5 HP model. A wider suction side suits a source line where keeping suction losses low matters, such as a longer draw from a pond or a lower tank, because the suction side of a centrifugal pump is where flow is easiest to lose. The listed flow of 64 gallons per minute at 20 PSI with a 5 foot lift matches the headline figure of the Goulds GT15, though the two pumps reach it with different port sizes and different internal parts.

The series document describes high head models delivering up to 145 feet of head with capacities to 95 GPM across the series. That is a series range, not a figure for the DS3HF alone, and it should be read as a ceiling for the family rather than a working point for this model. The working figures for the DS3HF are the flow steps at 20, 30, and 40 PSI, and they fall more steeply than the Franklin figures at higher pressure. Plan a tall tank fill around the 30 and 40 PSI steps. The document also lists single-body fill priming to 25 foot lifts, a drain port for winterising, and wearing parts that can be reached without disturbing piping or mounting, all practical points for a pump house or sheltered tank base that is serviced each season.

Pros: 2 inch suction port helps keep suction losses down; cast iron body with stainless steel shaft; service access without disturbing piping, as listed in the series document
Cons: Listed flow falls more steeply at 40 PSI than the Franklin model; single-phase motors ship set at 230 volts, so the voltage setting needs checking before first use

Red Lion RL-SPRK200

  • Horsepower: 2 HP
  • Voltage: 230 volts only, 10.9 running amps
  • Maximum flow: 76 gallons per minute
  • Flow at pressure: 76 GPM at 10 PSI, 64 GPM at 30 PSI
  • Maximum pressure: 49 PSI
  • Suction lift: 25 feet, with priming described as a one-time fill after which no further priming is listed as needed
  • Intake: 2 inch female NPT; discharge: 1.5 inch female NPT
  • Casing: cast iron; impeller and diffuser: thermoplastic, glass-filled in the product description
  • Motor: capacitor-run PSC design, thermally protected
  • Weight: 63 pounds; listed dimensions 21.85 by 11.42 by 10.2 inches

The RL-SPRK200 is the second model here with a 2 inch intake, and its listed figures are framed around pressure steps that are easy to plan with. The product page lists up to 76 gallons per minute at 10 PSI and 64 gallons per minute at 30 PSI, with a maximum pressure of 49 PSI. That maximum pressure is the ceiling for the model. A raised tank system whose total head, once friction and the tank inlet height are added, calls for pressure close to 49 PSI will see flow fall sharply, so the sensible planning figures are the 10 and 30 PSI steps, with room left above them.

Red Lion lists this model for residential and commercial lawn and turf sprinkling, handling up to 21 sprinkler heads with half-inch fittings in a zone, which gives a sense of its volume class even though tank filling is a different duty. For a tank, the steady point is the 64 gallons per minute listed at 30 PSI: a large tank fills at a useful rate as long as the total head stays in that part of the curve. The motor runs on 230 volts only and does not come with a cord arrangement for a standard outlet, so the installation calls for a wired circuit, planned with a qualified electrician where local codes require one. The cast iron casing and 63 pound weight point to a fixed installation on a firm base beside the source or below the tank, rather than a pump that is moved between jobs.

Pros: Wide 2 inch intake with clear flow figures at stated pressures; thermally protected motor; cast iron casing for a fixed installation
Cons: Maximum pressure of 49 PSI is the lowest ceiling in this guide; 230 volt only, with wiring planned as part of the installation

Buying guide

Start with total head, because that single calculation decides most of the choice. Total head for filling a raised tank has three parts. The first is the vertical distance from the surface of the source water to the inlet at the top of the raised tank, since the pump must push water through that full rise. The second is the suction side: the vertical distance from the source surface up to the pump, which the makers list as suction lift, with 25 feet as the listed limit on several models here. Keep the pump as low and as close to the source as the site allows, because suction lift spent on placement is lift that cannot be spent on the tank. The third part is friction loss in the pipe, valves, elbows, and fittings, which grows with longer runs, smaller pipe, and more bends. Add the three parts together before looking at any flow figure.

Then read flow at the pressure that matches that total head. Makers state flow in different ways: at a set head in feet, at a discharge pressure in PSI, or at a stated suction lift. As a rough conversion, one PSI corresponds to about 2.31 feet of head, so a system needing 46 feet of head is asking for roughly 20 PSI from the pump before any extra margin. Compare that requirement with the listed steps for each model. The Goulds GT15 lists flow at set head figures directly. The Franklin, Sta-Rite, and Red Lion models list flow at set pressures and a 5 foot lift. Pick the step at or just above your requirement and use that flow to estimate fill time: tank capacity in gallons divided by that flow gives minutes of running, before allowing for the slowdown as conditions change.

Treat every maximum as a ceiling. Maximum head, shut-off head, shut-off pressure, and maximum pressure all describe the point where the pump can push no further and flow falls to zero or near zero. A pump listed with a shut-off head of 121 feet will not fill a tank whose inlet sits 115 feet above the source at any useful rate. It will strain at the edge of its range. A sound rule from the listed figures is to keep the total head of the system well inside the published range, in the part of the curve where the maker still lists a solid flow figure. If your calculation lands between two listed steps, plan around the lower flow figure, not the higher one.

Port size and pipe size work together. Models here list either 1.5 inch suction and discharge ports, or a 2 inch suction with a 1.5 inch discharge. The suction side deserves the larger, straighter run wherever possible, with few elbows and a foot valve or check valve arrangement that holds prime between fills, as the Red Lion page describes for its intake line. Reducing the suction line below the listed port size, or adding tight bends close to the pump, adds losses that show up as slower filling and harder priming. The discharge side running up to the tank should be supported along the stand so its weight does not hang on the pump casing, and it should enter the tank in a way that avoids splashing losses and air being drawn back down the line when the pump stops.

Electrical supply is part of sizing, not a detail for later. Two of the 2 HP models here are 230 volt only, and the smaller Goulds and Sta-Rite models list dual voltage motors, with the Sta-Rite series document noting that single-phase motors ship set at 230 volts. Check the nameplate setting against the supply before the first start, and have wiring and grounding done to local code. A pump that fills a large tank may run for an extended stretch, so the circuit, the wire run to an outbuilding, and the motor protection listed for the model all matter. Several models list built-in thermal overload protection or a thermally protected motor; that protection is a safeguard for the motor, not a substitute for correct voltage.

Think about the fill cycle as a whole system. A raised tank often fills, rests, and feeds the garden by gravity, then fills again. Decide how the pump will know when to start and stop: a float switch in the tank, a timer, or manual running all appear in garden setups, and the pump choice should suit the pattern. A model with a back pull-out service design, listed on the Goulds and Franklin pumps, makes seal and impeller service simpler in a fixed installation. A built-in drain plug, listed on the Franklin model, and a drain port, listed in the Sta-Rite document, make winter draining simpler where freezing weather reaches the pump house. In warm districts, shade and ventilation around the motor matter more, along with the listed maximum water temperature where source water sits in sun.

Finally, match the pump to the source water. These are clean water irrigation pumps. Sandy or gritty source water wears impellers and seals faster, and the makers list different impeller materials across the group, from glass-filled Noryl to modified PPO and thermoplastic, with a stainless steel impeller version in the Franklin line. A strainer or intake screen sized for the source, checked often through the season, protects any of them. If the source is a lower storage tank rather than a pond or well, the same head maths applies, with the surface level of that lower tank as the starting point for both suction lift and total rise.

FAQ

How high can a centrifugal pump push water into a raised tank?

The makers list that limit as maximum head, shut-off head, or maximum pressure, depending on the brand. It is a ceiling: at that point flow falls to zero or near zero. The working answer comes from the flow figures listed at set pressures or head steps below the ceiling. Add the vertical rise to the tank inlet, the suction lift, and pipe friction, then choose a model that still lists a solid flow at that total.

Does a bigger horsepower rating always fill a tank faster?

Not on its own. Fill speed is the flow the maker lists at the pressure or head your system needs. In this guide, the 2 HP Franklin model lists 65 gallons per minute at 40 PSI with a 5 foot lift, while the 1.5 HP Sta-Rite model lists 35 gallons per minute at the same pressure and lift. Compare models at the same stated pressure and lift, rather than by horsepower or by the single largest flow figure on the page.

Where should the pump sit between the source and the raised tank?

Low and close to the source is the pattern the listed figures favour. Suction lift is limited, with 25 feet listed as the maximum on several models here, and flow figures are often stated at a 5 foot lift. A pump placed near the source spends little of its range on suction and keeps the rest for pushing water up to the tank. A pump placed high above the source, or far from it, gives up flow before the upward push even begins.

Do these pumps need priming before filling a tank?

The makers describe self-priming designs, and several describe a first fill after which the pump reprimes or holds its prime. That still calls for a correct first fill of the casing, a suction line without air leaks, and a foot valve or check valve arrangement where the maker describes one. Priming is not instant or automatic on a dry, newly plumbed system, and the Sta-Rite document lists priming times of less than 5 minutes to 25 foot lifts for its series once the body is filled.

Can one of these pumps fill a tank and run sprinklers at the same time?

The listed figures are for the pump as a whole, so flow shared between a tank line and a sprinkler line is flow divided. Most garden setups fill the tank and water the garden at different times, often using the raised tank itself to feed beds by gravity while the pump rests. If both jobs must run together, size the pump from the combined flow at the pressure the higher job needs, using the listed steps, and expect a larger model from this group to be the realistic fit.

What pipe size should run from the pump up to the tank?

Match the discharge port the maker lists, which is 1.5 inches across this group, and keep the suction side at its listed size, 1.5 or 2 inches depending on the model. Avoid shrinking the suction line, keep bends few and gradual, and support the rising discharge pipe on the tank stand. Smaller pipe and extra elbows add friction loss, which adds to total head and lowers the flow the pump delivers at the tank.

Conclusion

Filling a raised garden tank is a head job first and a flow job second. The six models here, the Goulds GT10, GT15, and GT20, the Franklin Electric Turf Boss FTB2CI, the Sta-Rite DS3HF Pro-Storm, and the Red Lion RL-SPRK200, all publish the figures needed to judge that job: flow at stated pressures or head steps, suction lift, port sizes, and a ceiling in the form of a shut-off head or maximum pressure. Read the ceiling as a limit, plan around the working flow step that covers your total head, and leave room above your calculation for friction and for the slower flow near the top of a tall fill.

For a shorter rise and a smaller tank, the GT10 keeps the system simple. For the middle ground that many raised tanks occupy, the GT15 and the DS3HF offer similar listed flow with different port layouts. For a taller stand, a longer run, or a larger tank, the GT20, the FTB2CI, and the RL-SPRK200 bring higher listed flow at working pressure, with the Franklin holding its flow furthest into the higher pressure steps. Whichever model fits, the maths is the same: measure the rise, count the lift, allow for the pipe, and let the listed figures, read carefully, make the choice.