Key takeaways
- Two-wire submersible pumps that fit a 5-inch casing, compared on listed head and flow: Franklin Tri-Seal, Grundfos SQ, Myers Predator Plus, Flint and Walling.
What's inside
As an Amazon Associate I earn from qualifying purchases. This post may contain affiliate links at no extra cost to you.
A 5-inch well casing is an in-between size. It is wider than the standard 4-inch casing most modern submersible pumps are built around, yet far narrower than the 6-inch casings of high-volume agricultural wells. The good news hidden in that odd size is clearance: any 4-inch-class pump, and even slimmer 3-inch pumps, drop into a 5-inch casing with room to spare for the drop cable and cable guard, which makes installation and future retrieval noticeably easier than in a tight 4-inch well. This guide compares the best 2 wire submersable water pumps for 5 well casings, meaning pumps whose starting components live inside the motor, so there is no control box to mount, wire or replace at the surface.
Two-wire construction matters most on exactly the wells that tend to have 5-inch casings: older installations, replacements and rural properties where the original control box is missing, corroded or simply one more failure point nobody wants. A 2-wire pump runs from the breaker through a pressure switch, and when something stops working the fault list is shorter. The five pumps below are all maker-listed 2-wire models with published performance tables, and all five measure 3.9 inches or less across, so each one fits a 5-inch casing with clearance rather than by force.
The set spans the realistic demand range for a house, cabin or small farm on a 5-inch well: a half-horsepower Flint & Walling for shallow, modest demand, three 1-horsepower workhorses from Franklin Electric and Myers, and a slim 3-inch Grundfos that adds electronic protection no conventional motor offers. Every figure in the product sections comes from the maker's own catalog, data booklet or retailer listing of that maker's data.
Quick verdict
The Franklin Electric Tri-Seal 10FA1S4-2W230 is the default pick for a typical home on a 5-inch casing: a 1 horsepower, 10 GPM-class 2-wire pump with a 434-foot shut-off head and strong delivery through normal household depths. The Grundfos 15 SQ10-250 is the technology pick, a 3-inch pump with a permanent-magnet motor, soft start and built-in dry-run and voltage protection. The Myers Predator Plus 2ST102-12PLUS-P4 brings stainless construction and a sand-tolerant floating impeller design, the Franklin 3200 Series 7FR1S4-2W230 is the slim 3.75-inch option for wells that have narrowed with age, and the Flint & Walling 4F07G07305 covers shallow wells and lighter demand at 3/4 horsepower.
| Product | Key spec | Best for |
|---|---|---|
| Franklin Electric Tri-Seal 10FA1S4-2W230 | 1 HP, shut-off 434 ft, 283 ft at 10 GPM | The default home pick for depth and flow |
| Grundfos 15 SQ10-250 | 1 HP, 287 ft at 15 GPM, 2.9 in diameter | Built-in protection and soft start |
| Myers Predator Plus 2ST102-12PLUS-P4 | 1 HP, 13 stages, 3-7/8 in diameter | Stainless build for sandy, aggressive water |
| Franklin Electric 3200 Series 7FR1S4-2W230 | 1 HP, shut-off 586 ft, 3.75 in diameter | Deep settings in a slim body |
| Flint & Walling 4F07G07305 | 3/4 HP, 7 GPM, max pressure 430 ft | Shallow wells and modest household demand |
How we chose
The first requirement was a genuine 2-wire build, confirmed in the maker's own model table rather than inferred from a product name. Each pick below appears in its maker's catalog with the wire count printed beside the model number, and each runs without a control box. Three-wire versions of several of these pumps exist and were deliberately passed over, because the whole point of this list is the simpler installation.
The second requirement was fit. A pump for a 5-inch casing should leave working clearance around the cable guard, so every pick measures 3.9 inches or less in maximum diameter. That ruled in the standard 4-inch-class pumps and the 3-inch Grundfos, and it is worth stating plainly that no true 5-inch pump class exists in these catalogs; 5-inch wells are served by 4-inch and 3-inch pumps, and the extra inch becomes installation room.
The third requirement was a published performance table deep enough to size against a real well: shut-off head, delivery at household pressures across a range of depths, and the electrical figures. All five makers print that data, and the figures quoted below are theirs.
Finally, the set was balanced by depth and demand. A 5-inch casing shows up on wells from 60 feet to several hundred, so the list runs from a 3/4 horsepower pump whose strength is shallow work to 1 horsepower models with shut-off heads past 400 and 500 feet.
Franklin Electric Tri-Seal 10FA1S4-2W230
- Build: 1 HP, 10 GPM class, 230 V, 2-wire (no control box)
- Head: 283 ft at 10 GPM; shut-off head 434 ft
- Output on a 30 PSI switch: 14 GPM at 80 ft depth, 13 GPM at 100 and 120 ft, 12 GPM at 140 and 160 ft
- Diameter: 3.90 in maximum across the cable guard; discharge 1-1/4 in NPT
- Stages: patented Tri-Seal floating stage design, 300-series stainless hubs, scalloped impellers, thermoplastic diffuser
- Check valve: removable, spring-loaded; maximum water temperature 120 degrees F
- Certifications and cover: UL 778, NSF/ANSI 61 for the pump end and NSF/ANSI 372; 12-month warranty
The Tri-Seal is Franklin Electric's floating-stage design, and the 10FA1S4-2W230 is its 1 horsepower, 10 GPM-class build with a stainless discharge head. The floating stages are the point of the design: each stage rides with a small amount of movement instead of being locked solid, which is how the maker addresses the downthrust wear that deep, high-head running puts on a pump end. The published numbers are strong for a 1 horsepower unit, holding 283 feet of head at the full 10 GPM rating and reaching a 434-foot shut-off.
On a household pressure switch the delivery holds up well through the depths most 5-inch wells present: 14 gallons per minute at an 80-foot pumping level on a 30 PSI cut-in, and still 12 gallons per minute at 160 feet. In a 5-inch casing the 3.90-inch body leaves a comfortable annulus for the drop cable, and the maker's install notes ask for the pump to sit at least 5 feet off the well bottom, standard practice that the extra casing room makes easy to honor.
The compromises are a 12-month warranty, the shortest cover on this list, and a clean-water brief: the listing's certifications suit potable household supply, and the pump belongs in a developed well rather than one still producing drilling sediment.
Pros: Strong head at full rated flow; floating stages aimed at downthrust wear; stainless discharge head; fits with real clearance and carries potable-water certifications.
Cons: 12-month warranty is the shortest here; 230 V only in this build; output figures assume a developed, clean well.
Grundfos 15 SQ10-250
- Build: 1 HP, 230 V, 2-wire plus ground; MS 3 permanent-magnet motor with built-in electronics
- Head: 287 ft at the rated 15 GPM; shut-off head 421 ft
- Output on a 30 PSI switch: 18.2 GPM at 140 ft depth, 15.8 at 200 ft, 13 at 240 ft, 10.3 at 280 ft
- Output on a 50 PSI switch: 16.4 GPM at 140 ft, 13.7 at 200 ft, 11.4 at 240 ft, 7.8 at 280 ft
- Diameter: 2.9 in; length within the family's 29.1 to 37.0 in range; discharge 1-1/4 in NPT
- Protection: dry-run, over- and under-voltage (cuts out below 150 V and above 315 V), overload, locked rotor and over-temperature, all built in
- Starting: soft start of about 3 seconds, no limit on starts per hour; built-in check valve; 5 ft 14 AWG motor cable with plug
- Setting: up to 500 ft below static level; water pH 5 to 9, up to 86 degrees F; warranty 24 months from installation, at most 30 months from manufacture
The SQ is the outlier here in the best way. At 2.9 inches in diameter it is a 3-inch pump, so in a 5-inch casing it drops in with more clearance than anything else on this list, and its permanent-magnet motor carries electronics that conventional 2-wire pumps simply do not have: soft starting that ramps up over about three seconds, dry-run protection, and voltage protection that cuts the motor out below 150 volts and above 315 volts and restarts it when the supply recovers. The maker is equally clear about the flip side: never connect a capacitor, a control box or an external drive to this motor.
Performance is rated at a nominal 15 GPM, higher than the other pumps here, and the sizing tables show 18.2 gallons per minute at a 140-foot depth on a 30 PSI switch. That output, in a pump light enough for one person to handle, makes it a strong choice for deeper 5-inch wells, for generator-backed properties where the soft start eases the load, and for voltage-unstable rural supplies.
The constraints are water quality and temperature: clean water, pH 5 to 9, no warmer than 86 degrees F, and a setting at least 20 inches below the pumping water level. The polyamide impellers and chambers also mark it as a clean-water machine, with tungsten carbide and ceramic bearings doing the wear work.
Pros: Built-in dry-run and voltage protection no rival here matches; soft start suits generators; slimmest body on the list; strong output at depth; longest stated warranty window.
Cons: Clean-water limits are strict, including an 86 degree F ceiling; electronics forbid any external drive or box; 230 V only at this size; replacement motor cable is a specific part.
Myers Predator Plus 2ST102-12PLUS-P4
- Build: 1 HP, 230 V, single phase, 2-wire; 13 stages; Pentek XE Series motor
- Class: 10/12 GPM; discharge 1-1/4 in NPT
- Dimensions: 3-7/8 in maximum outside diameter; assembled length 29 in; weight 35 lb
- Construction: stainless steel shell, discharge and intake; acetal impellers; polycarbonate diffusers
- Staging: SignaSeal floating impeller system with a harder-than-sand ceramic wear surface
- Bearings and valve: self-lubricating Nylatron discharge bearing; internal spring-loaded check valve
- Listings: CSA; the series spans heads to 1,950 ft and capacities to 65 GPM across all its models
Myers builds the Predator Plus around one problem: sand. The SignaSeal staging system pairs floating impellers with a ceramic wear surface the maker describes as harder than sand, aimed at the lock-up and abrasion problems that gritty well water causes. The 2ST102-12PLUS-P4 is the 1 horsepower, 2-wire build in the 10/12 GPM class, with 13 stages in a 29-inch assembled pump that weighs 35 pounds.
The construction list is the most metal-heavy here: stainless shell, stainless discharge head and intake, and stainless hardware throughout, with the wear handled by acetal impellers and polycarbonate diffusers inside. At 3-7/8 inches across it is the widest pump on this list, and in a 5-inch casing that still leaves over an inch of total clearance, which is precisely the situation this keyword describes. The tapered cable guard ends are a small, practical touch the maker notes for keeping the pump from catching on the casing on the way down or up.
What the data sheet does not give is a model-specific capacity table in text form; performance is published as curves, so the honest figures for this pick are its class, stage count and construction rather than a depth table. Buyers sizing a very deep well against a hard number should read the maker's curve for this model before ordering.
Pros: Stainless construction aimed at aggressive water; floating impellers with a ceramic wear surface for sandy wells; internal check valve included; tapered cable guard eases installation.
Cons: Widest body here, so casing clearance is the tightest of the five; model performance is published as curves rather than a text table; 35 lb is a two-hand lift on a long drop.
Franklin Electric 3200 Series 7FR1S4-2W230
- Build: 1 HP, 230 V, 2-wire; stainless discharge head build in the 7 GPM class
- Head: 438 ft at 7 GPM; the 7 GPM 1 HP class shut-off head is 586 ft
- Output on a 30 PSI switch: 12 GPM at 100 and 120 ft depth, 11 GPM from 140 to 200 ft
- Output on a 50 PSI switch: 11 GPM at 100 ft, 10 GPM from 160 to 200 ft
- Diameter: 3.75 in maximum across the cable guard; discharge 1-1/4 in NPT
- Stages: floating stage design; hex rubber bearing and ceramic shaft sleeve pass sand; thermoplastic diffuser with 300-series stainless thrust and eye protection
- Check valve: removable, spring-loaded; maximum water temperature 120 degrees F
- Certifications and cover: UL 778, CSA 108, NSF/ANSI 61 for the pump end and NSF/ANSI 372; 12-month warranty
The 3200 Series exists for wells that have narrowed. Franklin designs every part of the pump end, cable guard included, to fall within the diameter of its 4-inch motor, giving a 3.75-inch maximum that slides past the encrustation and slight casing irregularities older wells develop. A 5-inch casing in good condition gives it generous room; a 5-inch casing that has scaled down over decades is exactly its home ground.
The 7FR1S4-2W230 is the 1 horsepower stainless-head 2-wire build in the 7 GPM class, and its hydraulics are tuned for depth: 438 feet of head at the rated 7 GPM and a class shut-off of 586 feet, the highest here. On a pressure switch it delivers 12 gallons per minute at a 100-foot pumping level and holds 11 gallons per minute out to 200 feet, which covers most household demand from genuinely deep settings. The hex rubber bearing and ceramic shaft sleeve are the maker's sand answer, letting abrasive particles pass rather than grinding the shaft.
The series spans 24 to 47.8 inches in length and 26 to 50 pounds across its 50 builds, so the exact build's size should be confirmed on the listing. Like the Tri-Seal, the warranty runs 12 months, and the maker's notes specify positive-sealing check valves only, with the pump set at least 5 feet off the bottom.
Pros: Slimmest 4-inch-class body here for narrowed or scaled casings; highest shut-off head on the list; sand-passing bearing design; stainless discharge head on this build.
Cons: 7 GPM class is tuned for depth over volume; 12-month warranty; the 50-build range means the exact model string must be matched when ordering.
Flint & Walling 4F07G07305
- Build: 3/4 HP, 230 V, 2-wire; 14 stages; 3,450 RPM, 60 Hz
- Class: 7 GPM, with a recommended operating range of 2 to 13 GPM
- Output at 40 PSI discharge pressure: 12.2 GPM at 20 ft depth, 11.3 at 60 ft, 10.3 at 100 ft, 9.2 at 140 ft, 8.0 at 180 ft, 6.3 at 225 ft, 5.3 at 250 ft
- Maximum pressure: 430 ft (186 PSI)
- Construction: Noryl resin impellers and diffusers, cast iron discharge and NEMA mounting ring, stainless suction screen, stainless hex drive shaft, powder-coated carbon steel shell
- Check valve: positive-sealing, removable; motor is the maker's lightning-protected NEMA standard motor
- Fit: built for 4 in diameter wells or larger
Flint & Walling's G Series is the traditional American answer in this list: a cast iron discharge head, Noryl impellers and diffusers, a stainless hex shaft and a powder-coated steel shell, driven by the maker's own lightning-protected motor. The 4F07G07305 is the 3/4 horsepower, 2-wire, 230-volt build in the 7 GPM class, and the maker's catalog prints its full capacity table, which makes sizing refreshingly direct: at a 40 PSI discharge pressure it delivers 12.2 gallons per minute against a 20-foot depth to water and still 8 gallons per minute at 180 feet.
That profile suits the shallower end of 5-inch wells: cabins, smaller homes and farm outbuildings where the water level sits within the first couple of hundred feet and demand is steady rather than large. The catalog's maximum pressure figure of 430 feet gives the pump headroom well past its comfort zone, and the recommended operating range of 2 to 13 GPM brackets normal household use.
The catalog is equally clear about the wiring split in this family: the same pump end appears in 3-wire form with a control box ordered separately, while this 2-wire build needs none. The powder-coated carbon steel shell is the one construction compromise to note against the stainless shells elsewhere on this list, in exchange for the most complete published table here.
Pros: Full maker capacity table makes sizing exact; strong shallow-depth output for its horsepower; lightning-protected motor; positive-sealing removable check valve.
Cons: Powder-coated carbon steel shell rather than stainless; 3/4 HP runs out of depth sooner than the 1 HP picks; Noryl impellers are a clean-water design.
Buying guide
Size the pump to the pumping water level, not the well depth. The figure that matters is the depth to water while the pump is running, plus the pressure the system needs at the surface: every PSI of switch pressure adds about 2.31 feet of head, so a 30/50 switch asks for roughly 69 to 116 feet on top of the lift, before pipe friction. Read each maker's table at that total. The Tri-Seal holding 12 GPM at 160 feet on a 30 PSI switch and the Grundfos holding 13 GPM at 240 feet describe different wells, and both are honest numbers from their makers.
Use the casing clearance deliberately. In a 5-inch casing, a 3.9-inch pump leaves room for the cable to run without chafing, and the slim bodies here, the 3.75-inch Franklin 3200 and the 2.9-inch Grundfos, leave more. That room is not wasted space: it is what lets a pump be pulled in ten years without a fight, and it gives some tolerance if the casing has scaled. Measure the pump across the cable guard, since that is the widest point on every model here.
Decide what 2-wire simplicity is worth to you. The trade for losing the control box is losing the box's replaceable start components: on a 2-wire pump the starting gear lives in the motor, so a starting failure is a pump pull rather than a surface repair. Against that, there is no box to corrode, flood or be wired wrongly, and the Grundfos shows where the category is heading, with protection electronics built into the motor itself. On wells with a history of voltage trouble, that built-in protection is a genuine sizing factor, not a luxury.
Match the pump to the water. Sandy wells point to the Myers SignaSeal staging or the Franklin 3200's sand-passing bearing. Clean, deep wells suit the Tri-Seal's floating stages. The Grundfos asks for the cleanest water of all, with pH and temperature limits printed in its data. Every pump here belongs in a developed well, set at least 5 feet off the bottom where the maker specifies it, with positive-sealing check valves rather than swing types.
Finally, confirm the electrical basics before ordering: all five picks in their listed builds are 230-volt, the drop cable must be sized for the setting depth using the maker's cable table, and the pressure switch must be rated for the motor's current. A 2-wire install is simpler than a 3-wire one, but it is not forgiving of undersized cable on a deep drop.
FAQ
Will a 4-inch pump work properly in a 5-inch casing?
Yes. The makers list these pumps for 4-inch wells or larger, and a 5-inch casing simply adds clearance around the pump and cable guard. The one thing to manage is motor cooling flow past the motor on very high-yield wells, since the wider annulus slows the water moving past the motor; where a maker offers a flow sleeve for such cases, fit it. For normal household yields, the standard installation applies.
What is the practical difference between 2-wire and 3-wire pumps?
A 2-wire pump carries its starting components inside the motor and runs straight from the breaker through a pressure switch, with no control box. A 3-wire pump moves those components into a surface control box, which makes them replaceable without pulling the pump, at the cost of an extra component to install and maintain. Neither is more powerful; the choice is about where you want the service point to live.
How deep can these 2-wire pumps work?
The listed shut-off heads run from 421 feet for the Grundfos and 434 feet for the Tri-Seal up to 586 feet for the Franklin 3200's 7 GPM class, and the Flint & Walling lists a 430-foot maximum pressure. Working depth is always less than shut-off, since the pump must also make switch pressure at the surface; the makers' depth tables in each product section show the honest working figures.
Does the Grundfos SQ really need no control box or capacitor?
The maker states it directly: the SQ is a 2-wire pump with its electronics built into the motor, and a capacitor, control box or external frequency drive must never be connected. It runs from the breaker through a pressure switch rated for the motor's current, with a pressure tank, and its soft start and protection are handled internally.
How much clearance does a pump need inside the casing?
Enough for the pump, its cable guard and the drop cable to pass without binding, and to be retrieved years later. The widest pump here is 3-7/8 inches across, which leaves over an inch of total clearance in a 5-inch casing, and the slimmest, at 2.9 inches, leaves more than two. If a casing has heavy scale or a slight bend, that extra room is the difference between a routine pull and a stuck pump.
What should be replaced when swapping an old pump in a 5-inch well?
The makers' install notes point to the same list: new drop cable sized from the cable table, a splice kit, positive-sealing check valves rather than swing types, and a pressure switch rated for the new motor's draw. It is also the moment to confirm the pumping water level, since the new pump should be sized to the level the well actually holds under draw, not the static level measured at rest.
Conclusion
A 5-inch casing turns out to be an easy well to serve once the 2-wire requirement is set: the best 4-inch-class pumps fit with room to spare, and the slimmer designs fit with room to forgive an old casing's flaws. The Franklin Tri-Seal is the balanced default, the Grundfos 15 SQ10-250 the protected, soft-starting modern option, the Myers Predator Plus the sandy-water specialist, the Franklin 3200 the deep and narrow-well answer, and the Flint & Walling the straightforward shallow-well workhorse. Size whichever you choose against the pumping level and the maker's own table, and the absence of a control box will feel like what it is: one less thing between the well and the tap.
Write Your Review