Updated Th11 24, 2026· 16 min read

Key takeaways

  • A 500 ft well does not mean a 500 ft lift. Five 1 HP submersible pumps with maker-published shut-off heads past 500 ft, plus the flow tables to size them by.

As an Amazon Associate I earn from qualifying purchases. This post may contain affiliate links at no extra cost to you.

A 500 ft well frightens pump shoppers because the number sounds like a lift no 1 HP motor could manage, and most 1 HP submersibles on the market indeed cannot work anywhere near that class: their published curves end at 290 to 480 ft of head. But a 500 ft well does not ask for 500 ft of lift. It asks for enough head to raise water from the pumping water level — the depth the water surface falls to while the pump runs — plus the pressure the house system needs, plus friction in the drop pipe. The pump itself hangs deep in the well, often 400 ft or more down, yet the lift it works against may be far less than the well's total depth. Shopping for the best 1 h p well pumps for 500 ft well service therefore means reading makers' performance documents for two things: a shut-off head past 500 ft, which proves the pump belongs to the deep class at all, and flow figures at realistic depths and pressures, which prove it will still deliver water when the pressure switch calls.

That gate is strict, and it should be stated plainly: several widely sold 1 HP models fail it. A popular 10 GPM Franklin build stops at 480 ft of shut-off head, a common Grundfos 1 HP model at 290 ft, and two Goulds 1 HP models that roundup articles often recommend for deep wells top out, by their own maker's brochure arithmetic, at roughly 386 and 404 ft. The five pumps below are the ones whose makers publish the numbers that clear the bar: three Franklin Electric 3200 Series builds with shut-off heads of 586 to 666 ft, the Goulds 5GS10 at roughly 515 ft by its maker's chart, and the Zoeller Model 452 in its 11 GPM build at 504 ft by the maker's technical data sheet.

Every figure in this guide comes from a maker's catalog, brochure or technical data sheet for the named model, as published by the maker or reproduced in full by an authorized distributor. Where a figure is derived from a maker's chart rather than printed as a headline number, the derivation is shown.

Quick verdict

The Franklin Electric 3200 Series in its 5 GPM build is the lead pick for genuinely deep work: the maker's catalog data lists a 666 ft shut-off head, 529 ft of head at 4 GPM and 22 stages in a slim 3.75 in body that fits wells where a standard 4 in pump will not pass. The Goulds 5GS10 is the pick for sandy wells, with a floating impeller stack, stainless bowls and casing from the maker's brochure, and a selection chart that prints depth-to-water columns out to 1,020 ft. The Franklin 3200 Series 10 GPM build serves bigger households, holding a 618 ft shut-off head while roughly doubling the 5 GPM model's flow. The Zoeller Model 452 in its 11 GPM build is the transparency pick, the only maker here that publishes flow at 275 ft of depth to water against both 40 and 60 PSI on one sheet. The Franklin 3200 Series 7 GPM build is the middle path, at a 586 ft shut-off head with flow between its two siblings.

Product Key spec Best for
Franklin Electric 3200 Series 5 GPM, 1 HP 666 ft shut-off head, 22 stages, 3.75 in body The deepest settings and tight 4 in wells
Goulds 5GS10 About 515 ft shut-off head, floating impeller stack Sandy wells and long service runs
Franklin Electric 3200 Series 10 GPM, 1 HP 618 ft shut-off head, 471 ft at 6.5 GPM Larger households on deep wells
Zoeller Model 452, 11 GPM build 504 ft shut-off head, published 275 ft flow table Buyers who size strictly from maker tables
Franklin Electric 3200 Series 7 GPM, 1 HP 586 ft shut-off head, 486 ft at 5.5 GPM Mid-size households between the two

How we chose

The gate for this keyword was documentary, not reputational. A pump was admitted only if its maker's own published performance data — a catalog curve, a brochure selection chart or a technical data sheet — showed a shut-off head beyond 500 ft for the exact 1 HP build named. Shut-off head is the ceiling of the pump's curve, the point at which flow falls to zero, and it is the cleanest published proof that a pump belongs to the 500 ft class. Models whose makers publish lower ceilings were excluded however often they are recommended elsewhere, and two such exclusions are named in the introduction so the gate is auditable.

Shut-off head alone does not size a pump, so the second filter was usable flow data: published head figures at working flows for the Franklin builds, a depth-to-water selection chart for the Goulds, and depth-and-pressure flow tables for the Zoeller. A pump that clears 500 ft at shut-off but delivers almost nothing at a realistic total dynamic head is a technical pass and a practical failure, and the sections below say so where the published numbers point that way.

Construction evidence came from the same documents: stage counts, diameters, discharge sizes, materials and sand-handling design all appear below only as the makers publish them. Prices and retailer ratings played no part.

Franklin Electric 3200 Series 5 GPM, 1 HP (5FR1S4)

  • Shut-off head: 666 ft, per the maker's catalog data
  • Head at flow: 529 ft at 4 GPM; 430 ft at 5.5 GPM
  • Stages: 22
  • Diameter: 3.75 in
  • Discharge: 1-1/4 in NPT
  • Design: floating stage design, per the maker
  • Sand handling: hex rubber bearing and ceramic shaft sleeve, per the maker
  • Builds: thermoplastic or stainless construction; 2-wire and 3-wire versions
  • Control box: Franklin 2801084915 for 1 HP 3-wire builds, ordered separately

The 5 GPM build of Franklin's 3200 Series is the deepest-reaching 1 HP pump in this guide, and the published curve shows why the flow class matters. At shut-off it reaches 666 ft of head, a third again beyond the 500 ft gate, and it still holds 529 ft of head while delivering 4 GPM. Translated into a real system: against a pumping level of 380 ft, a 60 PSI pressure switch adds about 139 ft of head (each PSI costs 2.31 ft), for roughly 519 ft before friction — a duty this pump meets at about 4 GPM, where the larger-flow builds below are already falling away. Deep wells reward exactly this trade: modest flow at very high head.

The hardware suits the setting. Twenty-two stages generate the head, the floating stage design and the ceramic-and-rubber bearing set are Franklin's published answer to sand, and the 3.75 in diameter is the quiet advantage: in a 4 in well that has narrowed with mineral crust or a slightly out-of-round casing, a slim pump passes where a full-diameter one hangs up, hundreds of feet down. The 3200 line is sold in 2-wire builds that need no control box and 3-wire builds that use Franklin's 1 HP control box, ordered separately. Buyers should note the catalog variant label on this build quotes head at a stated flow rather than the shut-off ceiling; the figures above are the curve values from the maker's catalog data.

Pros:

  • Highest shut-off head here at 666 ft
  • Still delivers about 4 GPM against roughly 529 ft of head
  • Slim 3.75 in body fits tight or encrusted 4 in wells
  • Published sand-handling bearing design

Cons:

  • 5 GPM class is modest for large households with irrigation demand
  • 3-wire builds need a separate control box
  • Deepest capability is wasted on wells with shallow pumping levels

Goulds 5GS10

  • Shut-off head: about 515 ft, derived from the maker's selection chart (214 PSI shut-off at a 20 ft setting)
  • Stages: 20
  • Flow range: 1.2 to 7.5 GPM; best efficiency point 5 GPM
  • Water end: 21.7 in long, 13 lb
  • Impellers: Noryl, floating impeller stack
  • Diffusers: Lexan
  • Bowls and casing: AISI 304 stainless steel
  • Discharge head: cast 303 stainless steel with built-in check valve, BUNA seal
  • Discharge: 1-1/4 in
  • Minimum well size: 4 in
  • Selection chart: depth-to-water columns printed to 1,020 ft, per the maker's brochure

The Goulds entry earns its place differently from the Franklins: not with a headline shut-off figure, but with a selection chart that covers deep wells as normal business. The maker's brochure for the 5GS series prints depth-to-water columns running to 1,020 ft, and reading the 5GS10's shut-off row — 214 PSI at a 20 ft setting — through the standard conversion gives a shut-off head of roughly 515 ft, past the gate with a small margin. That margin is thinner than the Franklin 5 GPM's, so this pump suits wells whose pumping level and pressure total stays comfortably under 500 ft rather than at the edge of it.

What the Goulds offers in return is the most service-minded construction in the group. The floating impeller stack is the maker's sand answer, letting abrasive grains pass without grinding fixed impellers, and the materials list from the brochure reads like a longevity brief: Noryl impellers, Lexan diffusers, stainless bowls and casing, and a cast stainless discharge head with the check valve built in rather than added at the surface. The water end is compact and light at 21.7 in and 13 lb, which the crew lowering several hundred feet of pipe will appreciate. Its best efficiency point of 5 GPM matches the flow a typical household draws, so the pump spends its life near the part of the curve the maker designed it around.

Pros:

  • Maker's chart prints depth-to-water settings to 1,020 ft
  • Floating impeller stack for sandy water
  • Stainless bowls, casing and discharge head, per the brochure
  • Built-in check valve in the discharge head

Cons:

  • Shut-off margin past 500 ft is the thinnest here
  • Head figure must be derived from the chart's PSI row
  • Best efficiency at 5 GPM; output falls off above 7.5 GPM

Franklin Electric 3200 Series 10 GPM, 1 HP (10FRD1S4)

  • Shut-off head: 618 ft, per the maker's catalog data
  • Head at flow: 471 ft at 6.5 GPM; 319 ft at 9.5 GPM
  • Stages: 19
  • Diameter: 3.75 in
  • Discharge: 1-1/4 in NPT
  • Design: floating stage design, per the maker
  • Sand handling: hex rubber bearing and ceramic shaft sleeve, per the maker
  • Builds: 2-wire and 3-wire versions; 3-wire uses the Franklin 1 HP control box

Households grow out of 5 GPM. Add a second bathroom, a laundry that runs daily and any landscape watering, and the deeper question stops being whether the pump reaches and becomes how much it delivers when it gets there. The 10 GPM build of the same 3200 Series answers with a 618 ft shut-off head and 471 ft of head at 6.5 GPM — enough, on the arithmetic used throughout this guide, for a pumping level near 330 ft against a 60 PSI switch before friction, at a flow the 5 GPM build cannot approach at any head.

The published curve also marks the honest boundary. At 9.5 GPM the head falls to 319 ft, so a household that truly draws near 10 GPM at depth needs a pumping level well under 300 ft for this build to serve it at pressure. That is the shape of every high-head curve — flow and head trade against each other — and Franklin's catalog data makes the trade visible rather than hiding it behind a single rating. Hardware matches its siblings: 19 stages, the floating stage design, the slim 3.75 in body for tight casings, and the same bearing set for sand. Between this and the 5 GPM build, the choice is a measurement, not a preference: establish the pumping level, add the pressure head, and see which curve still shows your household's flow at that total.

Pros:

  • 618 ft shut-off head with roughly double the sibling's flow
  • Holds 471 ft at 6.5 GPM for larger households
  • Same slim 3.75 in body and sand-handling design
  • Maker publishes the full head-versus-flow trade

Cons:

  • Head falls to 319 ft at 9.5 GPM; deep high-flow duty exceeds it
  • Easy to oversize for wells with high pumping levels
  • 3-wire builds need the separate control box

Zoeller Model 452, 11 GPM build

  • Shut-off head: 504 ft (218 PSI), per Zoeller Technical Data FM3560
  • Flow at 40 PSI: 13.9 GPM at 20 ft depth to water; 10.1 at 180 ft; 8.8 at 225 ft; 7.0 at 275 ft
  • Flow at 60 PSI: 12.9 GPM at 20 ft; 8.7 at 180 ft; 5.0 at 275 ft
  • Shell and shaft: stainless steel shell and hex drive shaft
  • Impellers and diffusers: Noryl
  • Check valve: internal
  • Discharge: 1-1/4 in NPT
  • Power: 230V single phase, 8.2 A; 2-wire or 3-wire
  • Control box: Zoeller 10-2338 for 3-wire 1 HP builds, ordered separately
  • Listings: NSF/ANSI 61 and UL 778, per the maker's data
  • Warranty: 1-year limited, per the maker
  • Shipping weight: 33 to 36 lb

Zoeller publishes the most decision-ready document in this group. Its technical data sheet for the Model 452 prints flow against depth to water at both 40 and 60 PSI — the cut-in and cut-out of a standard pressure switch — so a buyer reads the actual delivery at the actual depth instead of converting a curve. On that table the 11 GPM build delivers 7.0 GPM at 275 ft against 40 PSI and 5.0 GPM against 60 PSI, figures that cover a household's needs at depths where most 1 HP pumps have stopped appearing in tables at all. The same sheet states the shut-off head plainly: 504 ft, or 218 PSI.

The candor cuts both ways, and the limit should be faced squarely: Zoeller's flow tables stop at 275 ft of depth to water. For a 500 ft well whose pumping level sits at 300 ft or deeper, the buyer is extrapolating from the curve's trend toward that 504 ft ceiling rather than reading a printed figure, and the prudent reading is that this pump fits 500 ft wells with moderate pumping levels better than extreme ones. Construction is conventional and sound — stainless shell and shaft, Noryl internals, an internal check valve, drinking-water listing — and the 1-year warranty is the shortest here. Note that the Model 452's 19 GPM build is a different pump for this purpose: its shut-off head is 283 ft, far under the gate, and only the 11 GPM build belongs in a 500 ft conversation.

Pros:

  • Maker publishes flow at depth against both switch pressures
  • Shut-off head of 504 ft stated directly on the data sheet
  • Stainless shell and shaft with an internal check valve
  • 2-wire builds need no control box

Cons:

  • Published flow tables stop at 275 ft depth to water
  • Shut-off margin past 500 ft is four feet; no room for error in the head math
  • 1-year warranty is the shortest here
  • The 19 GPM sibling build does not qualify for deep wells

Franklin Electric 3200 Series 7 GPM, 1 HP (7FR1S4)

  • Shut-off head: 586 ft, per the maker's catalog data
  • Head at flow: 486 ft at 5.5 GPM; 398 ft at 8 GPM
  • Stages: 18
  • Diameter: 3.75 in
  • Discharge: 1-1/4 in NPT
  • Design: floating stage design, per the maker
  • Sand handling: hex rubber bearing and ceramic shaft sleeve, per the maker
  • Builds: 2-wire and 3-wire versions

The 7 GPM build is the balancing point of the 3200 family, and its published curve shows a genuinely useful middle: 586 ft at shut-off, and 486 ft of head while delivering 5.5 GPM. Run the standard arithmetic — a pumping level of 340 ft plus a 60 PSI switch at about 139 ft totals roughly 479 ft before friction — and this build still delivers five-plus gallons a minute where the 10 GPM build has thinned out and with more flow than the 5 GPM build offers at the same head. For the common deep-well household, two or three people and no irrigation system, that is frequently the exact duty point.

It shares everything else with its siblings: 18 stages doing the work, the floating stage design, the slim 3.75 in diameter that eases past tight or scaled casing, the 1-1/4 in discharge, and the same bearing arrangement Franklin publishes for sand tolerance. The choice among the three Franklin builds is therefore a pure sizing exercise, and the maker's catalog data for all three makes it an honest one: pick the build whose curve still shows your required flow at your computed total dynamic head, with margin left for friction and for the water level's seasonal fall. Of the three, this is the build to start the comparison with, moving down to the 5 GPM for reach or up to the 10 GPM for flow as the numbers demand.

Pros:

  • Balanced curve: 486 ft of head at 5.5 GPM
  • 586 ft shut-off head clears the gate with margin
  • Slim body and sand-handling design shared with the range
  • Suits the most common household duty point

Cons:

  • Neither the deepest nor the highest-flowing build here
  • Same control-box requirement on 3-wire versions
  • Sizing still depends on knowing the true pumping level

Buying guide

Start with the well, not the pump. Three measurements decide everything: the well's total depth, the static water level, and the pumping level — the depth the water falls to while pumping, which a well report or a driller's test provides. The pump hangs below the pumping level with clearance from the bottom, and in a 500 ft well it may sit at 400 ft or deeper while lifting against far less than 400 ft. Anyone selling a pump for this well class without asking for the pumping level is guessing, and the makers' documents in this guide are built to be read against that number.

Convert the duty into total dynamic head. Add the pumping level, the pressure head — multiply the pressure switch's cut-out PSI by 2.31, so 60 PSI costs about 139 ft — and an allowance for friction in the drop pipe, which grows with flow and length. Then open the maker's curve or table for the build you are considering and find your flow at that head. If the curve shows your flow with margin, the pump fits; if the flow appears only near shut-off, it does not, whatever the horsepower badge says. The pumps here clear a 500 ft shut-off gate, but their working personalities differ sharply: the Franklin 5 GPM is still working at 529 ft, while the Zoeller's printed flows end at 275 ft of depth.

Choose the flow class by the household, then verify it against the curve. Five GPM serves a small household; 7 GPM is the common middle; 10 to 11 GPM serves larger homes — but only where the pumping level leaves the head to deliver it. Oversizing flow on a deep well is the classic error: the bigger build's curve collapses sooner at depth, and the smaller build out-delivers it where it matters.

Attend to the installation details the documents raise. Slim 3.75 in pumps pass tight or encrusted 4 in casings that stop standard bodies. Two-wire builds simplify the drop; three-wire builds need the maker's matching control box at the surface, which also makes one component serviceable without pulling the pump. Sand in the water argues for the floating-stack and floating-stage designs Goulds and Franklin publish. And at these depths the drop itself is a project — hundreds of feet of pipe, cable and safety line — so the pump chosen from a maker's full published curve, rather than a headline, is the one least likely to make the trip twice.

FAQ

Does a 500 ft well need a pump that can lift water 500 ft?

No. The pump lifts from the pumping water level, not from the bottom of the well, and adds pressure head and friction to that lift. A 500 ft well with a pumping level of 300 ft and a 60 PSI switch asks for roughly 439 ft of head before friction — within reach of the pumps here, and the reason shut-off heads past 500 ft mark the correct class.

How deep should the pump hang in a 500 ft well?

Below the pumping level by a comfortable margin, and off the bottom so it does not draw sediment — often in the lower portion of the well, set by the driller from the well's yield and drawdown figures. The setting depth and the lift are different numbers; the pump can hang at 450 ft while lifting against 400 ft of head.

Which flow class is right, 5, 7, 10 or 11 GPM?

Match it to the household first — small homes near 5 GPM, mid-size near 7, larger homes at 10 or more — then check the maker's curve at your total dynamic head. At depth the classes converge: the Franklin 10 GPM build delivers about 6.5 GPM at 471 ft of head, so a deep well's real delivery is set by the curve, not the class label.

Is 2-wire or 3-wire better at this depth?

Both appear across these makers' lines. Two-wire builds carry the starting components in the motor and need no surface box; three-wire builds use a control box at the surface — Franklin's 2801084915 or Zoeller's 10-2338 for these 1 HP models — which can be serviced or replaced without pulling several hundred feet of pump and pipe. For very deep settings, that service argument often decides it.

Why do so many 1 HP pumps fail the 500 ft test?

Because head costs stages, and most 1 HP models are built for the common 100 to 300 ft market with fewer stages and shut-off heads between about 290 and 480 ft. The pumps here reach past 500 ft with 18 to 22 stages in the Franklin and Goulds cases. Horsepower alone says nothing about head; the maker's published curve is the only reliable evidence.

What wears a deep-well pump out fastest?

Sand and grit, which the floating impeller and floating stage designs here are built to pass; short-cycling from an undersized pressure tank, which restarts the motor constantly; and running at the far right of the curve at low head and excessive flow. Correct sizing from the maker's table, a sound pressure tank and a pump matched to the water's sand content address all three.

Conclusion

The 500 ft well is a documentation test before it is a shopping test. Of the 1 HP field, the pumps whose makers publish shut-off heads beyond 500 ft form a short list: Franklin's 3200 Series in three flow classes, with the 5 GPM build reaching 666 ft and the 7 GPM build offering the balanced middle curve; the Goulds 5GS10, charted by its maker for settings beyond 1,000 ft of depth to water; and Zoeller's Model 452 in its 11 GPM build, with the most transparent depth-and-pressure tables of the group. Measure the pumping level, build the total dynamic head honestly, and read the maker's curve at that number — the pump that still shows your flow there is the right pump, and the documents above make that check possible for all five.

A
admin88
We compare specs, warranty terms, long-term owner feedback and street pricing before anything earns a spot. Rankings are never paid.
Affiliate disclosure. As an Amazon Associate we earn from qualifying purchases at no extra cost to you. Prices accurate as of the date shown.

Related guides

Browse all pumps guides →