Updated Th11 24, 2026· 14 min read

Key takeaways

  • Compare the best irrigation pumps for groundwater, self-priming sprinkler pumps with maker-listed flow at pressure, lift ratings, and port sizes and voltages.

As an Amazon Associate I earn from qualifying purchases. This post may contain affiliate links at no extra cost to you.

Drawing irrigation water from a well, a bore, or a shallow aquifer changes the pump question completely, and the best irrigation pumps for groundwater are the self-priming surface pumps that can lift water from below grade, hold their prime between cycles, and deliver sprinkler-level flow at sprinkler-level pressure for hours at a time. A groundwater source is not a pressurized supply: the pump has to create the pressure itself, starting from a suction lift that a transfer pump or a house jet pump was never designed around. That is why the lawn sprinkler pump class exists, with its own published flow tables measured at a stated lift.

The five pumps in this roundup are all members of that class, and all five draw their figures from maker catalogs and manuals rather than retail summaries. They span 1.5 and 2 horsepower, cast iron and thermoplastic housings, dual-voltage and 230-volt-only motors, and maximum flows from 67 to about 99 gallons per minute. What unites them is the job: sit at the wellhead or the cistern, pull groundwater up a suction line, and push it out to zones of sprinkler heads at 30 to 45 PSI.

This list was built to stand apart from the sibling roundup covering groundwater sprinkler systems, which used its own set of pumps. The models here are different units, chosen because their makers publish the numbers a groundwater installation actually turns on: flow at 10 and 30 PSI from a 5-foot lift, maximum suction lift, port sizes, and the voltage and amperage the circuit has to supply. Where a maker states a head count per zone, that figure is included, because it is the quickest sanity check of whether a pump matches the system being planned.

Quick verdict

The Red Lion RL-SPRK150 is the balanced pick for most groundwater-fed lawns: 1.5 horsepower, dual voltage, 71 GPM at 10 PSI and 44 GPM at 30 PSI, with the maker rating it for up to 14 half-inch heads per zone. The Goulds GT20 is the heavy lifter, a 2 horsepower self-priming centrifugal that still delivers 65 GPM at 40 PSI and reprimes against lifts up to 25 feet. The Wayne WLS200 matches that horsepower in cast iron with the highest low-pressure flow here, about 99 GPM at 10 PSI when its gallons-per-hour figures are converted. The Simer 3415P and the ECO-FLO EFLS15P are the lighter thermoplastic 1.5 horsepower options, both listing 67 GPM at 10 PSI and 48 GPM at 30 PSI, at weights a single person can carry easily.

Comparison table

Product Key spec Best for
Red Lion RL-SPRK150 1.5 HP, 71 GPM at 10 PSI and 44 GPM at 30 PSI, dual voltage Most groundwater-fed lawn systems
Goulds GT20 IRRI-Gator 2 HP, 86 GPM at 20 PSI, reprimes to 25 ft lift Large zones and deeper lifts
Wayne WLS200 2 HP cast iron, about 99 GPM at 10 PSI, 230 V High-flow systems on 230 V power
Simer 3415P 1.5 HP thermoplastic, 67 GPM at 10 PSI, 35 lb Lighter installs, water to 20 ft depth
ECO-FLO EFLS15P 1.5 HP, 67 GPM at 10 PSI and 48 GPM at 30 PSI, 43.2 lb Dual-voltage value pick

How we chose

Groundwater irrigation lives or dies on the suction side, so the first filter was a published lift rating. Every pump here is self-priming with a maker-stated maximum lift or reprime figure, because a pump that cannot re-establish prime after the suction line is opened for service will strand the whole system. The second filter was the shape of the flow table. Sprinkler zones run at pressure, so the figures that matter are the gallons per minute at 20, 30, and 40 PSI at a realistic 5-foot lift, and every maker here publishes exactly that row of numbers.

The third filter was installation fit: port sizes that match standard irrigation plumbing, voltage options that match what a wellhead or pump house can supply, and published amperage so the circuit can be sized before the pump arrives. Housing material was the fourth consideration, cast iron for permanence and rigidity at the ports, thermoplastic where lighter weight and corrosion resistance matter more. Finally, the set was checked against the sibling groundwater sprinkler-system roundup so that no model repeats, keeping this list an independent answer to the groundwater pump question.

Red Lion RL-SPRK150

  • Power: 1.5 HP, item 97101501
  • Voltage: 115/230 V, factory set to 230 V, 18.6 A at 115 V and 9.3 A at 230 V
  • Housing: cast iron with glass-filled thermoplastic impeller
  • Ports: 2 inch FNPT intake, 1-1/2 inch FNPT discharge
  • Flow at 5 ft lift: 71 GPM at 10 PSI, 60 GPM at 20 PSI, 44 GPM at 30 PSI
  • Maximum pressure: 44 PSI
  • Maximum flow: 71 GPM
  • Zone rating: up to 14 heads with 1/2 inch fittings, or 7 with 3/4 inch fittings, per zone
  • Priming: prime once to 25 ft, no additional priming after initial fill
  • Weight: about 63 lb

The RL-SPRK150 is the middle of the maker's cast iron sprinkler line, and its catalog row is the most complete quick reference in this roundup. The maker publishes the full flow staircase at a 5-foot lift, 71 gallons per minute at 10 PSI stepping down to 44 at 30 PSI, which is the pressure most lawn zones are designed around. The zone rating translates that curve into plain terms: up to 14 heads on half-inch fittings per zone. For a groundwater system, that is the number to hold against the zone plan before anything is ordered.

The dual-voltage motor ships set to 230 volts and can be switched to 115, and the maker publishes the draw at both settings, 18.6 amps at 115 volts being a figure that deserves respect when the circuit is planned. Priming is a one-time fill: the maker states the pump primes to 25 feet and needs no additional priming after the initial fill, which suits a wellhead installation that sits idle between watering days. The 2-inch intake is sized generously for the suction line, which is where a groundwater pump most needs low resistance.

Pros: Complete published flow staircase; dual voltage with stated amp draws; maker zone rating in plain head counts; one-time priming to 25 ft.
Cons: Maximum pressure of 44 PSI is the ceiling, so high-pressure zone designs have no headroom; at about 63 lb it is a fixed, two-person installation.

Goulds GT20 IRRI-Gator

  • Power: 2 HP, 230 V single-phase
  • Type: self-priming centrifugal
  • Flow at 5 ft lift: 86 GPM at 20 PSI, 80 GPM at 30 PSI, 65 GPM at 40 PSI
  • Capacity: up to 110 GPM
  • Head: up to 128 ft
  • Reprime: lifts to 25 ft
  • Ports: 1-1/2 inch NPT suction and discharge
  • Maximum working pressure: 125 PSI
  • Protection: built-in overload with automatic reset
  • Weight: 65 lb

The GT20 is the strongest pump in this roundup at working pressure, and its brochure figures show a curve that stays high where sprinkler zones actually run. Eighty gallons per minute at 30 PSI and 65 at 40 PSI, both at a 5-foot lift, will carry large residential or small commercial zones that would stall a 1.5 horsepower unit, and the maker rates total capacity up to 110 GPM with heads to 128 feet. For a groundwater source, the reprime figure matters just as much: the pump is rated to reprime against lifts up to 25 feet, so it recovers its prime across the full practical range of a shallow aquifer or well point installation.

The build details suit a permanent pump-house installation. Maximum working pressure is listed at 125 PSI, the overload protection is built in with automatic reset, and at 65 pounds the unit is meant to be bolted down once and left. The 230-volt single-phase motor has no 115-volt option, so the electrical plan has to be settled before purchase. Suction and discharge are both 1-1/2 inch NPT, a step down in port size from the Red Lion's 2-inch intake, which is worth noting when the suction run is long.

Pros: Highest flow at 30 and 40 PSI in this roundup; reprime rating to 25 ft; built-in overload protection; 125 PSI maximum working pressure.
Cons: 230 V only; both ports are 1-1/2 in, so long suction runs need care to keep friction losses down; heaviest class here at 65 lb.

Wayne WLS200

  • Power: 2 HP, 230 V only, cannot be converted
  • Duty: continuous-duty motor
  • Volute: cast iron with thermoplastic impeller
  • Ports: 2 inch NPT suction, 1-1/2 inch NPT discharge
  • Maximum vertical suction lift: 25 ft
  • Flow at 5 ft lift: 5,980 GPH at 10 PSI, 4,310 GPH at 30 PSI
  • Maximum load: 12.0 A
  • Liquid temperature range: 40 to 120 degrees F
  • Weight: about 60 lb
  • Priming: self-priming design

The WLS200 is the maker's 2 horsepower lawn sprinkler pump, and its manual publishes performance in gallons per hour: 5,980 GPH at 10 PSI and 4,310 GPH at 30 PSI at a 5-foot lift. Converted, those are about 99 and 72 gallons per minute, the strongest low-pressure figures in this roundup and a strong 30 PSI figure as well. The cast iron volute gives the ports rigidity, the motor is rated for continuous duty, which matches the long run times of irrigation cycles, and the maximum vertical suction lift is stated plainly at 25 feet.

The electrical specification is equally plain: 230 volts only, and the manual states the motor cannot be converted, with a maximum load of 12.0 amps. That firmness is useful information at planning time, because a site with only 115 volts at the wellhead rules this pump out immediately, while a site with a proper 230-volt circuit gets a simple, single-purpose machine. The stated liquid temperature range of 40 to 120 degrees F covers groundwater in any season it would be pumped for irrigation.

Pros: Highest converted flow at 10 PSI here, about 99 GPM; continuous-duty motor for long cycles; cast iron volute; 2 in suction port.
Cons: 230 V only with no conversion possible; performance published in GPH takes a conversion step before comparison with GPM-rated pumps.

Simer 3415P

  • Power: 1.5 HP
  • Voltage: 115/230 V
  • Housing: fiberglass-reinforced thermoplastic
  • Ports: 1-1/2 inch suction and discharge
  • Flow at 5 ft lift: 67 GPM at 10 PSI, 48 GPM at 30 PSI
  • Source depth: rated for water up to 20 ft below the pump
  • Priming: self-priming after initial fill
  • Weight: 35 lb
  • Warranty: 1 year, per the maker

The 3415P is the light, simple entry in the maker's sprinkler pump line, built in a fiberglass-reinforced thermoplastic housing that brings the weight down to 35 pounds, half the cast iron pumps here. Its sell sheet lists 67 gallons per minute at 10 PSI and 48 at 30 PSI at a 5-foot lift, figures that actually edge past the cast iron Red Lion at the 30 PSI point, and rates the pump for sources up to 20 feet below it. For a shallow groundwater source, a dug well, a cistern, or a lake-fed intake within that depth, the Simer covers the standard residential zone sizes.

Self-priming after the initial fill keeps seasonal startup simple, and the dual-voltage motor gives the installer a choice the Wayne does not offer. The trade-offs are the ones the spec sheet implies: a thermoplastic housing asks for a sheltered mounting and care with threaded fittings, and the stated source depth of 20 feet is a firmer ceiling than the 25-foot lift ratings of the heavier pumps. Within that ceiling, it is the easiest pump on this list to install, move, and store.

Pros: Lightest here at 35 lb; strong 48 GPM at 30 PSI; dual voltage; self-priming after initial fill.
Cons: Source depth rated to 20 ft rather than 25 ft; thermoplastic housing wants shelter and careful fitting work; shortest listed warranty at 1 year.

ECO-FLO EFLS15P

  • Power: 1.5 HP
  • Maximum flow: 67 GPM
  • Voltage: dual voltage, factory set to 230 V
  • Ports: 1-1/2 inch suction and discharge
  • Shaft: stainless steel
  • Priming: self-priming
  • Flow at 5 ft lift: 67 GPM at 10 PSI, 48 GPM at 30 PSI
  • Weight: 43.2 lb
  • Warranty: 1 year, per the maker

The EFLS15P is the maker's 1.5 horsepower sprinkler pump, and its specification sheet lands in the same performance place as the Simer: 67 gallons per minute maximum, with 48 GPM held at 30 PSI at a 5-foot lift. The details differ in ways that matter to an installer. The shaft is stainless steel, the motor is dual voltage but ships factory-set to 230 volts, and the weight of 43.2 pounds sits between the Simer's 35 and the cast iron pumps' 60-plus, reflecting a build that mixes lighter and heavier construction choices.

Like the Simer, it uses 1-1/2 inch suction and discharge ports and a self-priming design, so the two pumps compete directly for the same installations: shallow groundwater, cisterns, and lake intakes feeding residential zones. The choice between them comes down to the maker's stated figures for the specific site, the factory voltage preset, and which unit's documentation the installer prefers. Having two near-identical performers from different makers in the roundup is deliberate, because this is the size class most groundwater-fed home lawns actually need.

Pros: Matches the class benchmark of 67 GPM max and 48 GPM at 30 PSI; stainless steel shaft; dual voltage; mid-range weight.
Cons: Factory preset is 230 V, so 115 V installs need the change made first; warranty listed at 1 year; port sizes are 1-1/2 in rather than a 2 in suction.

Buying guide

Everything in groundwater irrigation starts at the suction line. The vertical distance from the pump down to the pumping water level, the level while the system runs, not the resting level, sets the lift the pump must handle, and every pump here is rated between 20 and 25 feet for that figure. Measure or estimate that level honestly, including seasonal drop in a dry summer, because a pump working at the edge of its lift rating loses flow quickly and can lose prime entirely. Keep the suction run short, use the port size the maker provides rather than reducing it, and fit a foot valve so the line stays full between cycles.

Next, size the pump to the largest zone, not to the whole system. Zones run one at a time, so the flow the pump must deliver is the flow of the biggest single zone at its design pressure, usually 30 to 40 PSI at the pump once line losses are added. Read that figure off the maker's table at your lift: the RL-SPRK150's 44 GPM at 30 PSI, the GT20's 80 GPM at the same point, and the Simer and ECO-FLO's 48 GPM define three clear size classes in this roundup. A pump one class too large wastes power and can over-pressurize small zones; a pump one class too small leaves the far heads weak, which no amount of run time fixes.

Electrical planning comes third, and the makers' published figures make it concrete. Dual-voltage pumps, the Red Lion, Simer, and ECO-FLO here, can be matched to the supply at the wellhead, but note the factory presets: the Red Lion and ECO-FLO ship set for 230 volts. The Wayne WLS200 cannot be converted from 230 volts at all, and the Red Lion's 18.6-amp draw at 115 volts shows why 230-volt operation is preferred where it is available: the same power at half the current. Size the breaker and wire from the published amperage, and put the pump on a circuit that is not shared with household loads.

Finally, think about where the pump lives. Cast iron housings, on the Red Lion, Goulds, and Wayne, suit a permanent pump house or wellhead slab and shrug off years of service. Thermoplastic housings, on the Simer and ECO-FLO, are lighter and will not corrode, which suits seasonal installations that get drained and stored. All five pumps need shelter from direct weather and a drain-down plan where winters freeze, since a self-priming pump full of water is as vulnerable to ice as any other plumbing. Choose the pump whose lift rating, 30 PSI flow, and voltage all match the site on paper first, and the installation will hold few surprises.

FAQ

How deep can these pumps draw groundwater from?

The makers rate the suction lift of these sprinkler pumps between 20 and 25 feet, measured to the pumping water level rather than the resting level. The Simer 3415P is rated for water up to 20 feet below the pump, while the Red Lion RL-SPRK150 primes to 25 feet and the Goulds GT20 reprimes against lifts up to 25 feet. Beyond those depths, a submersible pump in the well is the standard solution instead of a surface pump.

What does self-priming mean for a groundwater pump?

It means the pump can clear air from its suction line and establish flow after being filled once at installation, and can re-establish prime after the line has been opened, within its rated lift. The Red Lion states the arrangement plainly: prime to 25 feet with no additional priming after the initial fill. It does not mean the pump can start dry from any depth, which is why the lift rating still governs the installation.

How many sprinkler heads can one of these pumps run?

Per zone, the Red Lion publishes a direct answer for its pump: up to 14 heads with half-inch fittings or 7 with three-quarter-inch fittings. For the other pumps, divide the flow at your zone's design pressure by the flow each head uses. Using the published 30 PSI figures, the GT20 at 80 GPM carries roughly twice the zone of the RL-SPRK150 at 44 GPM, with the Simer and ECO-FLO at 48 GPM in between.

Should I choose 115 or 230 volts for a wellhead pump?

Where both are available, 230 volts is usually the better choice for pumps of this size because the current draw halves, as the Red Lion's figures show: 18.6 amps at 115 volts against 9.3 amps at 230 volts for the same pump. Lower current means less voltage drop on a long run to the wellhead. Two pumps here, the Wayne WLS200 and the Goulds GT20, are 230-volt only, so the supply has to be confirmed before ordering.

Why do the flow figures fall as pressure rises?

A pump's energy is split between moving water and pressurizing it, so the published tables always step down: the RL-SPRK150 goes from 71 GPM at 10 PSI to 44 GPM at 30 PSI, and the GT20 from 86 GPM at 20 PSI to 65 at 40 PSI. The figure to design with is the flow at the pressure your zones need, not the maximum flow, which is measured at a pressure too low to run sprinklers well.

Can a groundwater irrigation pump also supply the house?

These are irrigation pumps, built to run zones at steady flow for long cycles, and their pressure ceilings, 44 PSI maximum on the Red Lion, for example, sit below what a house pressure system with a tank and switch typically maintains. Household supply is a different pump class with its own roundup on this site. Keeping the two systems separate also keeps irrigation demand from competing with the house at peak times.

Conclusion

A groundwater irrigation pump earns its place on three published numbers: the lift it can prime against, the flow it holds at sprinkler pressure, and the voltage it needs. The Red Lion RL-SPRK150 balances all three for the typical home lawn, the Goulds GT20 serves the large-zone and deeper-lift end of the class, and the Wayne WLS200 brings the highest low-pressure flow to sites with 230-volt power. The Simer 3415P and ECO-FLO EFLS15P deliver the same 67 GPM class performance at weights one person can manage. Match the pump's table to your pumping level and your largest zone, and groundwater becomes as dependable a source as any pressurized supply.

A
admin88
We compare specs, warranty terms, long-term owner feedback and street pricing before anything earns a spot. Rankings are never paid.
Affiliate disclosure. As an Amazon Associate we earn from qualifying purchases at no extra cost to you. Prices accurate as of the date shown.

Related guides